{"datasheetResultDocument":{"certificateImages":{"ce":"/responsive/original/content/gallery/productcertificates/ce.png?v=-2057297231","ukca":"/responsive/original/content/gallery/productcertificates/ukca.png?v=-1942099300","cul":"/responsive/original/content/gallery/productcertificates/cul.png?v=-2057296668"},"completeFooter":"ifm efector, inc. • 1100 Atwater Drive • Malvern • PA 19355 — We reserve the right to make technical alterations without prior notice. — EN-US — MQ2005-01 — 13.04.2023","connections":[{"anschlussbelegungSubSections":[],"beschaltungSubSections":[{"connectionHeading":"","connectionImage":"https://media.ifm.com/dam/f8aa5c75-ca5e-4163-a3b6-ef5d5f435fcc/Original/AN_I_1020_G.jpg","connectionImageCaption":[[["td","4"],["td","OUT / IO-Link"]]],"connectionImageUrl":null,"footerText":[],"pinAssignment":[],"subsectionName":"Connection","type":"beschaltung"}],"connectionDescriptionAttachable":"","connectionDescriptionCable":"Cable: 0.3 m, PUR, Ø 4.9 mm; flame-retardant (IEC 60332-2, UL: FT2)","connectionDescriptionPlug":"Connector: 1 x M12; coding: A; Contacts: 3; Locking: Knurled nut, rotatable","connectionSubSectionList":[{"connectionHeading":"","connectionImage":"https://media.ifm.com/dam/f8aa5c75-ca5e-4163-a3b6-ef5d5f435fcc/Original/AN_I_1020_G.jpg","connectionImageCaption":[[["td","4"],["td","OUT / IO-Link"]]],"connectionImageUrl":null,"footerText":[],"pinAssignment":[],"subsectionName":"Connection","type":"beschaltung"}],"pinLayoutImage":"https://media.ifm.com/dam/cdecb1cf-797a-456e-a25d-8e87bbfc7acd/pim,w_0.6;r_pad,w_1.02,h_1.02,bc_white/PIN_0061.png","pinLayoutImageDesc":"Connector: 1 x M12; coding: A; Contacts: 3; Locking: Knurled nut, rotatable","pinLayoutImageUrl":null,"pinSubSections":[],"sectionName":"Electrical connection"}],"datasheetSections":[{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_elektrische-ausfuehrung","keyOrName":"at_elektrische-ausfuehrung","name":"Electrical design","tableValue":null,"type":"string","uom":"","value":"PNP/NPN;  (configurable)","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_ausgangsfunktion-digital","keyOrName":"at_ausgangsfunktion-digital","name":"Output function","tableValue":null,"type":"string","uom":"","value":"normally open / closed;  (configurable)","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_schaltabstand","keyOrName":"at_schaltabstand","name":"Sensing range","tableValue":null,"type":"string","uom":"[mm]","value":"5","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_kommunikationsschnittstelle","keyOrName":"at_kommunikationsschnittstelle","name":"Communication interface","tableValue":null,"type":"string","uom":"","value":"IO-Link","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_gehaeuse","keyOrName":"at_gehaeuse","name":"Housing","tableValue":null,"type":"string","uom":"","value":"rectangular","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_dimensions","keyOrName":"at_dimensions","name":"Dimensions","tableValue":null,"type":"string","uom":"[mm]","value":"20 x 8 x 32","valueList":null}],"name":""}],"sectionName":"Product characteristics"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_einsatzbereich-applikation","keyOrName":"at_einsatzbereich-applikation","name":"Application","tableValue":null,"type":"string","uom":"","value":"Industrial applications; Ferrous only","valueList":null}],"name":""}],"sectionName":"Application"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_betriebsspannung","keyOrName":"at_betriebsspannung","name":"Operating voltage","tableValue":null,"type":"string","uom":"[V]","value":"10...30 DC","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_bemessungsisolationsspannung","keyOrName":"at_bemessungsisolationsspannung","name":"Rated insulation voltage","tableValue":null,"type":"decimal","uom":"[V]","value":"60","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_stromaufnahme","keyOrName":"at_stromaufnahme","name":"Current consumption","tableValue":null,"type":"string","uom":"[mA]","value":"< 30","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_schutzklasse","keyOrName":"at_schutzklasse","name":"Protection class","tableValue":null,"type":"string","uom":"","value":"III","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_verpolungsschutz","keyOrName":"at_verpolungsschutz","name":"Reverse polarity protection","tableValue":null,"type":"string","uom":"","value":"yes","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_bereitschaftsverz-zeit","keyOrName":"at_bereitschaftsverz-zeit","name":"Power-on delay time","tableValue":null,"type":"string","uom":"[s]","value":"< 0.3","valueList":null}],"name":""}],"sectionName":"Electrical data"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_elektrische-ausfuehrung","keyOrName":"at_elektrische-ausfuehrung","name":"Electrical design","tableValue":null,"type":"string","uom":"","value":"PNP/NPN;  (configurable)","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_ausgangsfunktion-digital","keyOrName":"at_ausgangsfunktion-digital","name":"Output function","tableValue":null,"type":"string","uom":"","value":"normally open / closed;  (configurable)","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_max-spannungsabfall-schaltausg-dc","keyOrName":"at_max-spannungsabfall-schaltausg-dc","name":"Max. voltage drop switching output DC","tableValue":null,"type":"string","uom":"[V]","value":"2.5","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_max-reststrom","keyOrName":"at_max-reststrom","name":"Max. leakage current","tableValue":null,"type":"string","uom":"[mA]","value":"0.1","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_strombelastbarkeit-schaltausg-dc-dauer","keyOrName":"at_strombelastbarkeit-schaltausg-dc-dauer","name":"Permanent current rating of switching output DC","tableValue":null,"type":"string","uom":"[mA]","value":"100","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_strombelastbarkeit-schaltausg-kurz","keyOrName":"at_strombelastbarkeit-schaltausg-kurz","name":"Short-time current rating of switching output","tableValue":null,"type":"string","uom":"[mA]","value":"100","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_schaltfrequenz-dc-bereich","keyOrName":"at_schaltfrequenz-dc-bereich","name":"Switching frequency DC","tableValue":null,"type":"string","uom":"[Hz]","value":"200","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_ausgaenge-kurzschlussschutz","keyOrName":"at_ausgaenge-kurzschlussschutz","name":"Short-circuit protection","tableValue":null,"type":"string","uom":"","value":"yes","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_ausgaenge-kurzschlussschutz-ausfuehrung","keyOrName":"at_ausgaenge-kurzschlussschutz-ausfuehrung","name":"Type of short-circuit protection","tableValue":null,"type":"string","uom":"","value":"yes (non-latching)","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_ausgaenge-ueberlastfest","keyOrName":"at_ausgaenge-ueberlastfest","name":"Overload protection","tableValue":null,"type":"string","uom":"","value":"yes","valueList":null}],"name":""}],"sectionName":"Outputs"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_schaltabstand","keyOrName":"at_schaltabstand","name":"Sensing range","tableValue":null,"type":"string","uom":"[mm]","value":"5","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_realschaltabstand","keyOrName":"at_realschaltabstand","name":"Real sensing range Sr","tableValue":null,"type":"string","uom":"[mm]","value":"5 ± 10 %","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_arbeitsabstand","keyOrName":"at_arbeitsabstand","name":"Operating distance","tableValue":null,"type":"string","uom":"[mm]","value":"0...4.05","valueList":null}],"name":""}],"sectionName":"Monitoring range"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_korrekturfaktor","keyOrName":"at_korrekturfaktor","name":"Correction factor","tableValue":null,"type":"string","uom":"","value":"steel: 1","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_hysterese-prozent-sr-bereich","keyOrName":"at_hysterese-prozent-sr-bereich","name":"Hysteresis","tableValue":null,"type":"string","uom":"[% of Sr]","value":"< 10","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_schaltpunktdrift-prozent-sr-bereich","keyOrName":"at_schaltpunktdrift-prozent-sr-bereich","name":"Switch-point drift","tableValue":null,"type":"string","uom":"[% of Sr]","value":"-10...20","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_reproduzierbarkeit-prozent-sr-bereich","keyOrName":"at_reproduzierbarkeit-prozent-sr-bereich","name":"Repeatability","tableValue":null,"type":"string","uom":"[% of Sr]","value":"10","valueList":null}],"name":""}],"sectionName":"Accuracy / deviations"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_parametriermoeglichkeiten","keyOrName":"at_parametriermoeglichkeiten","name":"Parameter setting options","tableValue":null,"type":"string","uom":"","value":"hysteresis / window; switch-off delay; switch-on operations; Auto-teach","valueList":null}],"name":""}],"sectionName":"Software / programming"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_kommunikationsschnittstelle","keyOrName":"at_kommunikationsschnittstelle","name":"Communication interface","tableValue":null,"type":"string","uom":"","value":"IO-Link","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_iolink-transferetype","keyOrName":"at_iolink-transferetype","name":"Transmission type","tableValue":null,"type":"string","uom":"","value":"COM2 (38,4 kBaud)","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_iolink-revision","keyOrName":"at_iolink-revision","name":"IO-Link revision","tableValue":null,"type":"string","uom":"","value":"1.1","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_iolink-sdci-norm","keyOrName":"at_iolink-sdci-norm","name":"SDCI standard","tableValue":null,"type":"string","uom":"","value":"IEC 61131-9 CDV","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_iolink-profile-tabelle","keyOrName":"at_iolink-profile-tabelle","name":"Profiles","tableValue":[[["td","Smart Sensor - SSP 0"],["td","Generic Profiled Sensor"]],[["td","Common - I&D"],["td","Identification and Diagnosis"]],[["td","Function"],["td","Multiple switching signal"]],[["td","Function"],["td","Teach channel"]]],"type":"text-table","uom":"","value":null,"valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_iolink-siomode","keyOrName":"at_iolink-siomode","name":"SIO mode","tableValue":null,"type":"string","uom":"","value":"yes","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_iolink-porttype","keyOrName":"at_iolink-porttype","name":"Required master port class","tableValue":null,"type":"string","uom":"","value":"A","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_iolink-min-prozesszykluszeit","keyOrName":"at_iolink-min-prozesszykluszeit","name":"Min. process cycle time","tableValue":null,"type":"decimal","uom":"[ms]","value":"9.6","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_iolink-prozessdaten-zyklisch","keyOrName":"at_iolink-prozessdaten-zyklisch","name":"IO-Link process data (cyclical)","tableValue":[[["th","Function"],["th","bit length"]],[["td","process value"],["td","16"]],[["td","device status"],["td","4"]],[["td","binary switching information"],["td","4"]]],"type":"text-table","uom":"","value":null,"valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_iolink-funktionen-azyklisch","keyOrName":"at_iolink-funktionen-azyklisch","name":"IO-Link functions (acyclical)","tableValue":null,"type":"string","uom":"","value":"application specific tag; operating hours counter; switching cycles counter","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_iolink-deviceids","keyOrName":"at_iolink-deviceids","name":"Supported DeviceIDs","tableValue":[[["th","Type of operation"],["th","DeviceID"]],[["td","default"],["td","830"]]],"type":"text-table","uom":"","value":null,"valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_iolink-deviceids-zusatz","keyOrName":"at_iolink-deviceids-zusatz","name":"Note","tableValue":[[["td"," For further information please see the IODD PDF file at \"Downloads\""]]],"type":"text-table","uom":"","value":null,"valueList":null}],"name":""}],"sectionName":"Interfaces"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_umgebungstemperatur-cel-bereich","keyOrName":"at_umgebungstemperatur-cel-bereich","name":"Ambient temperature","tableValue":null,"type":"string","uom":"[°C]","value":"-25...80","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_lagertemperatur-cel-bereich","keyOrName":"at_lagertemperatur-cel-bereich","name":"Storage temperature","tableValue":null,"type":"string","uom":"[°C]","value":"-30...85","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_schutzart","keyOrName":"at_schutzart","name":"Protection","tableValue":null,"type":"string","uom":"","value":"IP 65; IP 67","valueList":null}],"name":""}],"sectionName":"Operating conditions"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_emv","keyOrName":"at_emv","name":"EMC","tableValue":[[["td","EN 61000-4-2 ESD"],["td","4 kV CD / 8 kV AD"]],[["td","EN 61000-4-3 HF radiated"],["td","10 V/m"]],[["td","EN 61000-4-4 Burst"],["td","2 kV"]],[["td","EN 61000-4-6 HF conducted"],["td","10 V"]],[["td","EN 55011"],["td","class B"]]],"type":"text-table","uom":"","value":null,"valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_schwingfestigkeit","keyOrName":"at_schwingfestigkeit","name":"Vibration resistance","tableValue":[[["td","EN 60068-2-6 Fc"],["td","20 g (10...3000 Hz) / 50 sweep cycles per frequency; 1 octave per minute in 3 axes"]]],"type":"text-table","uom":"","value":null,"valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_schockfestigkeit","keyOrName":"at_schockfestigkeit","name":"Shock resistance","tableValue":[[["td","EN 60068-2-27 Ea"],["td","100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes"]]],"type":"text-table","uom":"","value":null,"valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_dauerschockfestigkeit","keyOrName":"at_dauerschockfestigkeit","name":"Continuous shock resistance","tableValue":[[["td","EN 60068-2-27"],["td","40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes"]]],"type":"text-table","uom":"","value":null,"valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_mttf","keyOrName":"at_mttf","name":"MTTF","tableValue":null,"type":"decimal","uom":"[years]","value":"1976","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_zulassung-ul","keyOrName":"at_zulassung-ul","name":"UL approval","tableValue":[[["td","Ta"],["td","-25...60 °C"]],[["td","Enclosure type"],["td","Type 1 "]],[["td","voltage supply"],["td","Limited Voltage/Current "]],[["td","UL approval number"],["td","C010 "]],[["td","File number UL"],["td","E174191 "]]],"type":"text-table","uom":"","value":null,"valueList":null}],"name":""}],"sectionName":"Tests / approvals"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_erp-bruttogewicht-wert","keyOrName":"at_erp-bruttogewicht-wert","name":"Weight","tableValue":null,"type":"decimal","uom":"[g]","value":"44.9","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_gehaeuse","keyOrName":"at_gehaeuse","name":"Housing","tableValue":null,"type":"string","uom":"","value":"rectangular","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_einbauart","keyOrName":"at_einbauart","name":"Mounting","tableValue":null,"type":"string","uom":"","value":"flush mountable","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_dimensions","keyOrName":"at_dimensions","name":"Dimensions","tableValue":null,"type":"string","uom":"[mm]","value":"20 x 8 x 32","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_werkstoffe-gehaeuse-text","keyOrName":"at_werkstoffe-gehaeuse-text","name":"Material","tableValue":null,"type":"string","uom":"","value":"diecast zinc; LED window: TPU (urethane); potting: PUR","valueList":null}],"name":""}],"sectionName":"Mechanical data"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_anzeige","keyOrName":"at_anzeige","name":"Display","tableValue":[[["td","Display operation"],["td","1 x LED, green"]],[["td","Switching status"],["td","1 x LED, yellow"]]],"type":"text-table","uom":"","value":null,"valueList":null}],"name":""}],"sectionName":"Displays / operating elements"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_verpackungseinheit","keyOrName":"at_verpackungseinheit","name":"Pack quantity","tableValue":null,"type":"string","uom":"","value":"1 pcs.","valueList":null}],"name":""}],"sectionName":"Remarks"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":null,"inlineImageUrl":null,"key":"cable connection","keyOrName":"cable connection","name":"Cable","tableValue":null,"type":"String","uom":"","value":"0.3 m, PUR, Ø 4.9 mm; flame-retardant (IEC 60332-2, UL: FT2)","valueList":null},{"inlineImage":null,"inlineImageUrl":null,"key":"plug connection","keyOrName":"plug connection","name":"Connector","tableValue":null,"type":"String","uom":"","value":"1 x M12; coding: A; Contacts: 3; Locking: Knurled nut, rotatable","valueList":null}],"name":null}],"sectionName":"Electrical connection"}],"diagramSections":[],"footerAddress":"ifm efector, inc. • 1100 Atwater Drive • Malvern • PA 19355","footerDate":null,"footerRemark":"We reserve the right to make technical alterations without prior notice.","freeTableSection":null,"infoBox":[{"text":"Article to be discontinued ","type":"info"},{"text":"Alternative articles:  <a href=\"./IQ2012\">IQ2012</a> Product comparison:  <a href=\"../productComparison?p1=MQ2005&p2=IQ2012&\">MQ2005 / IQ2012</a> When selecting an alternative article and accessories please note that technical data may differ! ","type":"info"}],"lastModified":"Sun Aug 16 01:32:00 CEST 2026","madeInRemark":"","scaleDrawingLegend":[[["td","1"],["td","LED yellow"]],[["td","2"],["td","LED green"]]],"scaleDrawingRef":"https://media.ifm.com/dam/f181e3cd-e279-4d35-9bbc-ba147ff8a442/pim,w_0.9;r_pad,w_2000,h_1.01,bc_white/P_MZ_100_0958.png"},"defaultPdfDatasheetUrl":"https://media.ifm.com/dam/7be65638-59b7-4aa0-829f-55462ea5a3f8/Original/MQ2005-01_EN-US.pdf","scaleDrawingUrl":"https://media.ifm.com/dam/f181e3cd-e279-4d35-9bbc-ba147ff8a442/pim,w_0.9;r_pad,w_2000,h_1.01,bc_white/P_MZ_100_0958.png"}