{"datasheetResultDocument":{"certificateImages":{"ce":"/responsive/original/content/gallery/productcertificates/ce.png?v=-2057297231","ukca":"/responsive/original/content/gallery/productcertificates/ukca.png?v=-1942099300"},"completeFooter":"ifm efector, inc. • 1100 Atwater Drive • Malvern • PA 19355 — We reserve the right to make technical alterations without prior notice. — EN-US — JAC201-00 — 25.04.2023","connections":[{"anschlussbelegungSubSections":[],"beschaltungSubSections":[],"connectionDescriptionAttachable":"","connectionDescriptionCable":"","connectionDescriptionPlug":"Connector: 1 x M12; coding: A; Contacts: 3","connectionSubSectionList":[{"connectionHeading":"","connectionImage":"https://media.ifm.com/dam/109ae604-d7e7-4f6f-871e-3d93b1b182f7/Original/AN_I_0047.jpg","connectionImageCaption":[],"connectionImageUrl":null,"footerText":[],"pinAssignment":[],"subsectionName":"Connection","type":"pin"}],"pinLayoutImage":"https://media.ifm.com/dam/cdecb1cf-797a-456e-a25d-8e87bbfc7acd/pim,w_0.6;r_pad,w_1.02,h_1.02,bc_white/PIN_0061.png","pinLayoutImageDesc":"Connector: 1 x M12; coding: A; Contacts: 3","pinLayoutImageUrl":null,"pinSubSections":[{"connectionHeading":"","connectionImage":"https://media.ifm.com/dam/109ae604-d7e7-4f6f-871e-3d93b1b182f7/Original/AN_I_0047.jpg","connectionImageCaption":[],"connectionImageUrl":null,"footerText":[],"pinAssignment":[],"subsectionName":"Connection","type":"pin"}],"sectionName":"Electrical connection - plug"}],"datasheetSections":[{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_elektrische-ausfuehrung","keyOrName":"at_elektrische-ausfuehrung","name":"Electrical design","tableValue":null,"type":"string","uom":"","value":"PNP","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_gehaeuse","keyOrName":"at_gehaeuse","name":"Housing","tableValue":null,"type":"string","uom":"","value":"Threaded type","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_dimensions","keyOrName":"at_dimensions","name":"Dimensions","tableValue":null,"type":"string","uom":"[mm]","value":"M12 x 1 / L = 63","valueList":null}],"name":""}],"sectionName":"Product characteristics"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_einsatzbereich-applikation","keyOrName":"at_einsatzbereich-applikation","name":"Application","tableValue":null,"type":"string","uom":"","value":"High switching frequency for fast processes","valueList":null}],"name":""}],"sectionName":"Application"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_betriebsspannung","keyOrName":"at_betriebsspannung","name":"Operating voltage","tableValue":null,"type":"string","uom":"[V]","value":"10...30 DC","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_stromaufnahme","keyOrName":"at_stromaufnahme","name":"Current consumption","tableValue":null,"type":"string","uom":"[mA]","value":"< 15","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_schutzklasse","keyOrName":"at_schutzklasse","name":"Protection class","tableValue":null,"type":"string","uom":"","value":"III","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_verpolungsschutz","keyOrName":"at_verpolungsschutz","name":"Reverse polarity protection","tableValue":null,"type":"string","uom":"","value":"yes","valueList":null}],"name":""}],"sectionName":"Electrical data"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_elektrische-ausfuehrung","keyOrName":"at_elektrische-ausfuehrung","name":"Electrical design","tableValue":null,"type":"string","uom":"","value":"PNP","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_ausgaenge-kurzschlussschutz","keyOrName":"at_ausgaenge-kurzschlussschutz","name":"Short-circuit protection","tableValue":null,"type":"string","uom":"","value":"yes","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_ausgaenge-kurzschlussschutz-ausfuehrung","keyOrName":"at_ausgaenge-kurzschlussschutz-ausfuehrung","name":"Type of short-circuit protection","tableValue":null,"type":"string","uom":"","value":"yes (non-latching)","valueList":null}],"name":""}],"sectionName":"Outputs"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_umgebungstemperatur-cel-bereich","keyOrName":"at_umgebungstemperatur-cel-bereich","name":"Ambient temperature","tableValue":null,"type":"string","uom":"[°C]","value":"-25...70","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_schutzart","keyOrName":"at_schutzart","name":"Protection","tableValue":null,"type":"string","uom":"","value":"IP 65; IP 67; IP 68;  (\"Coolant\")","valueList":null}],"name":""}],"sectionName":"Operating conditions"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_emv","keyOrName":"at_emv","name":"EMC","tableValue":[[["td","EN 61000-4-2 ESD"],["td","4 kV CD / 8 kV AD"]],[["td","EN 61000-4-3 HF radiated"],["td","10 V/m (80...1000 MHz)"]],[["td","EN 61000-4-4 Burst"],["td","2 kV"]],[["td","EN 61000-4-5 Surge"],["td","0,5 kV"]],[["td","EN 61000-4-6 HF conducted"],["td","10 V (0,15...80 MHz)"]],[["td","EN 55011"],["td","class B"]]],"type":"text-table","uom":"","value":null,"valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_mttf","keyOrName":"at_mttf","name":"MTTF","tableValue":null,"type":"decimal","uom":"[years]","value":"1048","valueList":null}],"name":""}],"sectionName":"Tests / approvals"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_erp-bruttogewicht-wert","keyOrName":"at_erp-bruttogewicht-wert","name":"Weight","tableValue":null,"type":"decimal","uom":"[g]","value":"34.8","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_gehaeuse","keyOrName":"at_gehaeuse","name":"Housing","tableValue":null,"type":"string","uom":"","value":"Threaded type","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_dimensions","keyOrName":"at_dimensions","name":"Dimensions","tableValue":null,"type":"string","uom":"[mm]","value":"M12 x 1 / L = 63","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_gewindebezeichnung","keyOrName":"at_gewindebezeichnung","name":"Thread designation","tableValue":null,"type":"string","uom":"","value":"M12 x 1","valueList":null}],"name":""}],"sectionName":"Mechanical data"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_verpackungseinheit","keyOrName":"at_verpackungseinheit","name":"Pack quantity","tableValue":null,"type":"string","uom":"","value":"1 pcs.","valueList":null}],"name":""}],"sectionName":"Remarks"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":null,"inlineImageUrl":null,"key":"plug connection","keyOrName":"plug connection","name":"Connector","tableValue":null,"type":"String","uom":"","value":"1 x M12; coding: A; Contacts: 3","valueList":null}],"name":null}],"sectionName":"Electrical connection - plug"}],"diagramSections":[],"footerAddress":"ifm efector, inc. • 1100 Atwater Drive • Malvern • PA 19355","footerDate":null,"footerRemark":"We reserve the right to make technical alterations without prior notice.","freeTableSection":null,"infoBox":[],"lastModified":"Sun Aug 16 13:47:07 CEST 2026","madeInRemark":"","scaleDrawingLegend":[],"scaleDrawingRef":"https://media.ifm.com/dam/419ac746-a1f4-4f60-b8b4-451d2746492a/pim,w_0.9;r_pad,w_2000,h_1.01,bc_white/P_MZ_100_0254.png"},"defaultPdfDatasheetUrl":"https://media.ifm.com/dam/558e1303-8c73-4368-961d-fc7610964d87/Original/JAC201-00_EN-US.pdf","scaleDrawingUrl":"https://media.ifm.com/dam/419ac746-a1f4-4f60-b8b4-451d2746492a/pim,w_0.9;r_pad,w_2000,h_1.01,bc_white/P_MZ_100_0254.png"}