{"datasheetResultDocument":{"certificateImages":{"csa":"/responsive/original/content/gallery/productcertificates/csa.png?v=-2057296625","ce":"/responsive/original/content/gallery/productcertificates/ce.png?v=-2057297231","ukca":"/responsive/original/content/gallery/productcertificates/ukca.png?v=-1942099300","cruus":"/responsive/original/content/gallery/productcertificates/cruus.png?v=-2057296507"},"completeFooter":"ifm efector, inc. • 1100 Atwater Drive • Malvern • PA 19355 — We reserve the right to make technical alterations without prior notice. — EN-US — E74220-00 — 17.09.2025","connections":[{"anschlussbelegungSubSections":[],"beschaltungSubSections":[],"connectionDescriptionAttachable":"","connectionDescriptionCable":"Cable: 100 m, TPE, red; 2 x 1.5 mm²","connectionDescriptionPlug":"","connectionSubSectionList":[],"pinLayoutImage":"","pinLayoutImageDesc":"","pinLayoutImageUrl":null,"pinSubSections":[],"sectionName":"Electrical connection"}],"datasheetSections":[{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_besondere-eigenschaft","keyOrName":"at_besondere-eigenschaft","name":"Special feature","tableValue":null,"type":"string","uom":"","value":"Drag chain suitability","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_einsatzbereich-applikation","keyOrName":"at_einsatzbereich-applikation","name":"Application","tableValue":null,"type":"string","uom":"","value":"Industrial applications","valueList":null}],"name":""}],"sectionName":"Application"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_betriebsspannung","keyOrName":"at_betriebsspannung","name":"Operating voltage","tableValue":null,"type":"string","uom":"[V]","value":"230 DC;  (Peak voltage 300 V)","valueList":null}],"name":""}],"sectionName":"Electrical data"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_umgebungstemperatur-cel-bereich","keyOrName":"at_umgebungstemperatur-cel-bereich","name":"Ambient temperature","tableValue":null,"type":"string","uom":"[°C]","value":"-40...105","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_umgebungstemperatur-bewegt-cel-bereich","keyOrName":"at_umgebungstemperatur-bewegt-cel-bereich","name":"Ambient temperature (moving)","tableValue":null,"type":"string","uom":"[°C]","value":"-30...105","valueList":null}],"name":""}],"sectionName":"Operating conditions"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_zulassung-ul","keyOrName":"at_zulassung-ul","name":"UL approval","tableValue":[[["td","AWM style"],["td","2103 "]],[["td","File number UL"],["td","E130266 "]]],"type":"text-table","uom":"","value":null,"valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_csa-zulassung","keyOrName":"at_csa-zulassung","name":"CSA approval","tableValue":[[["td","file number"],["td","LL55255-42 "]]],"type":"text-table","uom":"","value":null,"valueList":null}],"name":""}],"sectionName":"Tests / approvals"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_erp-bruttogewicht-wert","keyOrName":"at_erp-bruttogewicht-wert","name":"Weight","tableValue":null,"type":"decimal","uom":"[g]","value":"6960","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_schleppketteneignung-vorhanden","keyOrName":"at_schleppketteneignung-vorhanden","name":"Drag chain suitability","tableValue":null,"type":"string","uom":"","value":"yes","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_schleppketteneignung","keyOrName":"at_schleppketteneignung","name":"Drag chain suitability","tableValue":[[["td","Bending radius for flexible applications"],["td","75 mm"]],[["td","Travel speed"],["td","max. 4 m/s at 10 m horizontal travel length and max. acceleration of 4 m/s²"]],[["td","Bending cycles"],["td","≥ 10 Mio"]],[["td","Torsional strain"],["td","360°/m"]]],"type":"text-table","uom":"","value":null,"valueList":null}],"name":""}],"sectionName":"Mechanical data"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_bemerkungen","keyOrName":"at_bemerkungen","name":"Remarks","tableValue":[[["td","100 m form supplied: coiled"]]],"type":"text-table","uom":"","value":null,"valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_verpackungseinheit","keyOrName":"at_verpackungseinheit","name":"Pack quantity","tableValue":null,"type":"string","uom":"","value":"100 m","valueList":null}],"name":""}],"sectionName":"Remarks"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":null,"inlineImageUrl":null,"key":"cable connection","keyOrName":"cable connection","name":"Cable","tableValue":null,"type":"String","uom":"","value":"100 m, TPE, red; 2 x 1.5 mm²","valueList":null}],"name":null}],"sectionName":"Electrical connection"}],"diagramSections":[],"footerAddress":"ifm efector, inc. • 1100 Atwater Drive • Malvern • PA 19355","footerDate":null,"footerRemark":"We reserve the right to make technical alterations without prior notice.","freeTableSection":null,"infoBox":[],"lastModified":"Tue Oct 13 08:23:33 CEST 2026","madeInRemark":"Made in Germany","scaleDrawingLegend":[],"scaleDrawingRef":"https://media.ifm.com/dam/2be308b6-c15e-4e5c-ae67-69501d69e2ae/pim,w_0.9;r_pad,w_2000,h_1.01,bc_white/P_MZ_Z_0916.png"},"defaultPdfDatasheetUrl":"https://media.ifm.com/dam/3f2e2d6d-4fd1-4ffc-bdc2-e2dea7a6ca88/Original/E74220-00_EN-US.pdf","scaleDrawingUrl":"https://media.ifm.com/dam/2be308b6-c15e-4e5c-ae67-69501d69e2ae/pim,w_0.9;r_pad,w_2000,h_1.01,bc_white/P_MZ_Z_0916.png"}