{"datasheetResultDocument":{"certificateImages":{"fcm_jp":"/responsive/original/content/gallery/productcertificates/fcm_jp.png?v=-95608114","fda":"/responsive/original/content/gallery/productcertificates/fda.png?v=-2057278884","hyg_cln":"/responsive/original/content/gallery/productcertificates/hyg_cln.png?v=577138905","ec19352004":"/responsive/original/content/gallery/productcertificates/ec19352004.png?v=-2057295599","adi_free":"/responsive/original/content/gallery/productcertificates/adi_free.png?v=1969232083","fcm_cn":"/responsive/original/content/gallery/productcertificates/fcm_cn.png?v=-95603739","3a":"/responsive/original/content/gallery/productcertificates/3a.png?v=-2057290140"},"completeFooter":"ifm efector, inc. • 1100 Atwater Drive • Malvern • PA 19355 — We reserve the right to make technical alterations without prior notice. — EN-US — E40485-00 — 18.03.2024","connections":[],"datasheetSections":[{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_ausfuehrung","keyOrName":"at_ausfuehrung","name":"Design","tableValue":null,"type":"string","uom":"","value":"for flow meter SMF","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_einsatzbereich-applikation","keyOrName":"at_einsatzbereich-applikation","name":"Application","tableValue":null,"type":"string","uom":"","value":"food and beverage industry; hygienic systems","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_druckfestigkeit-generictable","keyOrName":"at_druckfestigkeit-generictable","name":"Pressure rating","tableValue":[[["td","10 bar"],["td","1 MPa"]]],"type":"text-table","uom":"","value":null,"valueList":null}],"name":""}],"sectionName":"Application"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_druckgeraeterichtlinie","keyOrName":"at_druckgeraeterichtlinie","name":"Pressure equipment directive","tableValue":null,"type":"string","uom":"","value":"A possible classification to PED depends on the application and has to be carried out by the user / operator.","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_sicherheitshinweise","keyOrName":"at_sicherheitshinweise","name":"Safety instructions","tableValue":null,"type":"string","uom":"","value":"The compatibility between medium and  product material has to be checked in all applications.","valueList":null}],"name":""}],"sectionName":"Tests / approvals"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_erp-bruttogewicht-wert","keyOrName":"at_erp-bruttogewicht-wert","name":"Weight","tableValue":null,"type":"decimal","uom":"[g]","value":"3935","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_gehaeuse","keyOrName":"at_gehaeuse","name":"Housing","tableValue":null,"type":"string","uom":"","value":"tubular","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_dimensions","keyOrName":"at_dimensions","name":"Dimensions","tableValue":null,"type":"string","uom":"[mm]","value":"Ø 139 / L = 42.9","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_werkstoffe-gehaeuse-text","keyOrName":"at_werkstoffe-gehaeuse-text","name":"Material","tableValue":null,"type":"string","uom":"","value":"stainless steel (1.4404 / 316L)","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_nennweite","keyOrName":"at_nennweite","name":"Nominal diameter","tableValue":null,"type":"string","uom":"","value":"DN80 (3“)","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_sensorikanschluss","keyOrName":"at_sensorikanschluss","name":"Sensor connection","tableValue":null,"type":"string","uom":"","value":"ifm-specific device flange","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_prozessanschluss","keyOrName":"at_prozessanschluss","name":"Process connection","tableValue":null,"type":"string","uom":"","value":"Clamp ISO 2852","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_rohrnorm-text","keyOrName":"at_rohrnorm-text","name":"Process connection suitable for pipe standard","tableValue":null,"type":"string","uom":"","value":" (ISO 2037);  (DIN EN 10357 series C);  (DIN EN 10357 series D)","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_oberflaechenbeschaffenheit","keyOrName":"at_oberflaechenbeschaffenheit","name":"Surface characteristics Ra/Rz of the wetted parts","tableValue":null,"type":"string","uom":"","value":"Ra < 0.4 µm","valueList":null}],"name":""}],"sectionName":"Mechanical data"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_zubehoer-mitgeliefert","keyOrName":"at_zubehoer-mitgeliefert","name":"Items supplied","tableValue":[[["td","screws 12"]]],"type":"text-table","uom":"","value":null,"valueList":null}],"name":""}],"sectionName":"Accessories"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_verpackungseinheit","keyOrName":"at_verpackungseinheit","name":"Pack quantity","tableValue":null,"type":"string","uom":"","value":"2 pcs.","valueList":null}],"name":""}],"sectionName":"Remarks"}],"diagramSections":[],"footerAddress":"ifm efector, inc. • 1100 Atwater Drive • Malvern • PA 19355","footerDate":null,"footerRemark":"We reserve the right to make technical alterations without prior notice.","freeTableSection":null,"infoBox":[],"lastModified":"Wed Sep 02 19:32:56 CEST 2026","madeInRemark":"Made in Germany","scaleDrawingLegend":[],"scaleDrawingRef":"https://media.ifm.com/dam/b6e1dfd7-d9ba-4011-9e89-6bc28115c852/pim,w_0.9;r_pad,w_2000,h_1.01,bc_white/P_MZ_Z_1901.png"},"defaultPdfDatasheetUrl":"https://media.ifm.com/dam/faa9b038-a6de-4ef0-b9f1-d45e2bfe3c5a/Original/E40485-00_EN-US.pdf","scaleDrawingUrl":"https://media.ifm.com/dam/b6e1dfd7-d9ba-4011-9e89-6bc28115c852/pim,w_0.9;r_pad,w_2000,h_1.01,bc_white/P_MZ_Z_1901.png"}