{"datasheetResultDocument":{"certificateImages":{"cul":"/responsive/original/content/gallery/productcertificates/cul.png?v=-2057296668"},"completeFooter":"ifm efector, inc. • 1100 Atwater Drive • Malvern • PA 19355 — We reserve the right to make technical alterations without prior notice. — EN-US — DTI901-00 — 05.07.2023","connections":[{"anschlussbelegungSubSections":[{"connectionHeading":"","connectionImage":"","connectionImageCaption":[],"connectionImageUrl":null,"footerText":[],"pinAssignment":[[["td","1 Sensor supply"],["td","L+"]],[["td","2 not used"],["td",""]],[["td","3 Sensor supply"],["td","L-"]],[["td","4 IO-Link"],["td",""]],[["td","5 not used"],["td",""]]],"subsectionName":"","type":"anschlussbelegung"}],"beschaltungSubSections":[],"connectionDescriptionAttachable":"","connectionDescriptionCable":"","connectionDescriptionPlug":"Connector: 1 x M12; coding: A; Contacts: 5","connectionSubSectionList":[{"connectionHeading":"","connectionImage":"","connectionImageCaption":[],"connectionImageUrl":null,"footerText":[],"pinAssignment":[[["td","1 Sensor supply"],["td","L+"]],[["td","2 not used"],["td",""]],[["td","3 Sensor supply"],["td","L-"]],[["td","4 IO-Link"],["td",""]],[["td","5 not used"],["td",""]]],"subsectionName":"","type":"anschlussbelegung"}],"pinLayoutImage":"https://media.ifm.com/dam/20f6da2a-1c3b-48c8-88cc-511666400fce/pim,w_0.6;r_pad,w_1.02,h_1.02,bc_white/PIN_0063.png","pinLayoutImageDesc":"Connector: 1 x M12; coding: A; Contacts: 5","pinLayoutImageUrl":null,"pinSubSections":[],"sectionName":"Electrical connection"}],"datasheetSections":[{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_einsatzbereich-applikation","keyOrName":"at_einsatzbereich-applikation","name":"Application","tableValue":null,"type":"string","uom":"","value":"Detection of objects on transport equipment","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_funkzulassung-fuer","keyOrName":"at_funkzulassung-fuer","name":"Radio approval for","tableValue":null,"type":"string","uom":"","value":"Canada; USA","valueList":null}],"name":""}],"sectionName":"Application"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_betriebsspannung","keyOrName":"at_betriebsspannung","name":"Operating voltage","tableValue":null,"type":"string","uom":"[V]","value":"18...30 DC","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_stromaufnahme","keyOrName":"at_stromaufnahme","name":"Current consumption","tableValue":null,"type":"string","uom":"[mA]","value":"< 250","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_leistungsaufnahme","keyOrName":"at_leistungsaufnahme","name":"Power consumption","tableValue":null,"type":"string","uom":"[W]","value":"4.8","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_schutzklasse","keyOrName":"at_schutzklasse","name":"Protection class","tableValue":null,"type":"string","uom":"","value":"III","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_arbeitsfrequenz","keyOrName":"at_arbeitsfrequenz","name":"Operating frequency","tableValue":null,"type":"string","uom":"[MHz]","value":"902...928","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_rfid-standard","keyOrName":"at_rfid-standard","name":"RFID standard","tableValue":null,"type":"string","uom":"","value":"EPC Class1 GEN2/ISO 18000-63","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_sendeleistung-eirp","keyOrName":"at_sendeleistung-eirp","name":"Transmission power EIRP","tableValue":null,"type":"string","uom":"[mW]","value":"200;  (maximum: 410 mW)","valueList":null}],"name":""}],"sectionName":"Electrical data"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_kommunikationsschnittstelle","keyOrName":"at_kommunikationsschnittstelle","name":"Communication interface","tableValue":null,"type":"string","uom":"","value":"IO-Link","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_iolink-transferetype","keyOrName":"at_iolink-transferetype","name":"Transmission type","tableValue":null,"type":"string","uom":"","value":"COM3 (230,4 kBaud)","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_iolink-revision","keyOrName":"at_iolink-revision","name":"IO-Link revision","tableValue":null,"type":"string","uom":"","value":"1.1","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_iolink-profile-tabelle","keyOrName":"at_iolink-profile-tabelle","name":"Profiles","tableValue":[[["td","Smart Sensor - SSP 0"],["td","Generic Profiled Sensor"]],[["td","Common - I&D"],["td","Identification and Diagnosis"]]],"type":"text-table","uom":"","value":null,"valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_iolink-min-prozesszykluszeit","keyOrName":"at_iolink-min-prozesszykluszeit","name":"Min. process cycle time","tableValue":null,"type":"decimal","uom":"[ms]","value":"4","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_iolink-deviceids","keyOrName":"at_iolink-deviceids","name":"Supported DeviceIDs","tableValue":[[["th","Type of operation"],["th","DeviceID"]],[["td","default"],["td","1418"]]],"type":"text-table","uom":"","value":null,"valueList":null}],"name":""}],"sectionName":"Interfaces"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_umgebungstemperatur-cel-bereich","keyOrName":"at_umgebungstemperatur-cel-bereich","name":"Ambient temperature","tableValue":null,"type":"string","uom":"[°C]","value":"-20...60","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_lagertemperatur-cel-bereich","keyOrName":"at_lagertemperatur-cel-bereich","name":"Storage temperature","tableValue":null,"type":"string","uom":"[°C]","value":"-25...80","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_schutzart","keyOrName":"at_schutzart","name":"Protection","tableValue":null,"type":"string","uom":"","value":"IP 67","valueList":null}],"name":""}],"sectionName":"Operating conditions"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_schockfestigkeit","keyOrName":"at_schockfestigkeit","name":"Shock resistance","tableValue":[[["td","EN 60068-2-27"],["td","40 g 6 ms / bump"]],[["td","EN 60068-2-27"],["td","50 g 11 ms / single shock"]]],"type":"text-table","uom":"","value":null,"valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_vibrationsfestigkeit","keyOrName":"at_vibrationsfestigkeit","name":"Vibration resistance","tableValue":[[["td","EN 60068-2-6"],["td","2 g 10...150 Hz"]]],"type":"text-table","uom":"","value":null,"valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_elektrische-sicherheit","keyOrName":"at_elektrische-sicherheit","name":"Electrical safety","tableValue":[[["td","EN 61010-2-201"],["td","electrical supply only via PELV circuits"]]],"type":"text-table","uom":"","value":null,"valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_mttf","keyOrName":"at_mttf","name":"MTTF","tableValue":null,"type":"decimal","uom":"[years]","value":"71","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_zulassung-ul","keyOrName":"at_zulassung-ul","name":"UL approval","tableValue":[[["td","Ta"],["td","-20…60 °C"]],[["td","Enclosure type"],["td","Type 1 "]],[["td","voltage supply"],["td","Limited Voltage/Current "]],[["td","File number UL"],["td","E205959 "]]],"type":"text-table","uom":"","value":null,"valueList":null}],"name":""}],"sectionName":"Tests / approvals"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_erp-bruttogewicht-wert","keyOrName":"at_erp-bruttogewicht-wert","name":"Weight","tableValue":null,"type":"decimal","uom":"[g]","value":"635.8","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_dimensions","keyOrName":"at_dimensions","name":"Dimensions","tableValue":null,"type":"string","uom":"[mm]","value":"120 x 50 x 113","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_werkstoffe-gehaeuse-text","keyOrName":"at_werkstoffe-gehaeuse-text","name":"Material","tableValue":null,"type":"string","uom":"","value":"PBT; PC; stainless steel; aluminum","valueList":null}],"name":""}],"sectionName":"Mechanical data"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_anzeige","keyOrName":"at_anzeige","name":"Display","tableValue":[[["td","Power"],["td","1 x LED, green"]],[["td","tag communication"],["td","4 x LED display, yellow number of tags in the field"]]],"type":"text-table","uom":"","value":null,"valueList":null}],"name":""}],"sectionName":"Displays / operating elements"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_verpackungseinheit","keyOrName":"at_verpackungseinheit","name":"Pack quantity","tableValue":null,"type":"string","uom":"","value":"1 pcs.","valueList":null}],"name":""}],"sectionName":"Remarks"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":null,"inlineImageUrl":null,"key":"plug connection","keyOrName":"plug connection","name":"Connector","tableValue":null,"type":"String","uom":"","value":"1 x M12; coding: A; Contacts: 5","valueList":null}],"name":null}],"sectionName":"Electrical connection"}],"diagramSections":[],"footerAddress":"ifm efector, inc. • 1100 Atwater Drive • Malvern • PA 19355","footerDate":null,"footerRemark":"We reserve the right to make technical alterations without prior notice.","freeTableSection":null,"infoBox":[],"lastModified":"Fri Apr 24 21:41:38 CEST 2026","madeInRemark":"Made in Germany","scaleDrawingLegend":[[["td","1"],["td","LED operating status"]],[["td","2"],["td","LED display"]],[["td","3"],["td","Mounting thread:  M4 max. insertion depth:  15 mm"]]],"scaleDrawingRef":"https://media.ifm.com/dam/5ea3e5be-e912-4a19-80bd-9ce884ca619d/pim,w_0.9;r_pad,w_2000,h_1.01,bc_white/P_MZ_190_0024.png"},"defaultPdfDatasheetUrl":"https://media.ifm.com/dam/a2ba66ca-48be-4c7c-a3f3-c5fd91380ea8/Original/DTI901-00_EN-US.pdf","scaleDrawingUrl":"https://media.ifm.com/dam/5ea3e5be-e912-4a19-80bd-9ce884ca619d/pim,w_0.9;r_pad,w_2000,h_1.01,bc_white/P_MZ_190_0024.png"}