{"datasheetResultDocument":{"certificateImages":{"ce":"/responsive/original/content/gallery/productcertificates/ce.png?v=-2057297231","ukca":"/responsive/original/content/gallery/productcertificates/ukca.png?v=-1942099300","cul":"/responsive/original/content/gallery/productcertificates/cul.png?v=-2057296668","cruus":"/responsive/original/content/gallery/productcertificates/cruus.png?v=-2057296507"},"completeFooter":"ifm efector, inc. • 1100 Atwater Drive • Malvern • PA 19355 — We reserve the right to make technical alterations without prior notice. — EN-US — DN4014-00 — 28.01.2026","connections":[{"anschlussbelegungSubSections":[],"beschaltungSubSections":[{"connectionHeading":"","connectionImage":"https://media.ifm.com/dam/efbcc988-a3bc-4b34-9bd8-b3177c584da1/pim,w_0.45;r_pad,w_1.02,h_1.02,bc_white/AN_i_1378.png","connectionImageCaption":[[["td","1:"],["td","primary"]],[["td","2:"],["td","secondary"]]],"connectionImageUrl":null,"footerText":[],"pinAssignment":[],"subsectionName":"Connection","type":"beschaltung"}],"connectionDescriptionAttachable":"screw terminals: ","connectionDescriptionCable":"","connectionDescriptionPlug":"","connectionSubSectionList":[{"connectionHeading":"","connectionImage":"https://media.ifm.com/dam/efbcc988-a3bc-4b34-9bd8-b3177c584da1/pim,w_0.45;r_pad,w_1.02,h_1.02,bc_white/AN_i_1378.png","connectionImageCaption":[[["td","1:"],["td","primary"]],[["td","2:"],["td","secondary"]]],"connectionImageUrl":null,"footerText":[],"pinAssignment":[],"subsectionName":"Connection","type":"beschaltung"}],"pinLayoutImage":"","pinLayoutImageDesc":"","pinLayoutImageUrl":null,"pinSubSections":[],"sectionName":"Electrical connection"}],"datasheetSections":[{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_ausfuehrung","keyOrName":"at_ausfuehrung","name":"Design","tableValue":null,"type":"string","uom":"","value":"housing for DIN rail mounting","valueList":null}],"name":""}],"sectionName":"Application"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_betriebsspannung-ac-frequenz-bereich","keyOrName":"at_betriebsspannung-ac-frequenz-bereich","name":"Frequency AC","tableValue":null,"type":"string","uom":"[Hz]","value":"47...64","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_nennspannung-ac","keyOrName":"at_nennspannung-ac","name":"Nominal voltage AC","tableValue":null,"type":"string","uom":"[V]","value":"< 230","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_eingangsspannung-netzteil-ac","keyOrName":"at_eingangsspannung-netzteil-ac","name":"Input voltage range AC","tableValue":null,"type":"string","uom":"[V]","value":"100...240; (-15 % / +10 %)","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_ausgangsspannung-netzteil-dc-bereich","keyOrName":"at_ausgangsspannung-netzteil-dc-bereich","name":"Output voltage DC","tableValue":null,"type":"string","uom":"[V]","value":"24...28","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_schutzklasse","keyOrName":"at_schutzklasse","name":"Protection class","tableValue":null,"type":"string","uom":"","value":"I;  (IEC 61140)","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_ueberspannungsschutz","keyOrName":"at_ueberspannungsschutz","name":"Overvoltage protection","tableValue":null,"type":"string","uom":"","value":"yes;  (< 32 DC)","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_ausgangsspannung-netzteil","keyOrName":"at_ausgangsspannung-netzteil","name":"Output voltage","tableValue":null,"type":"string","uom":"[V]","value":"adjustable; output voltage to SELV, PELV","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_ausgangsstrom-max-ausgangssp-min-netzteil-dauer","keyOrName":"at_ausgangsstrom-max-ausgangssp-min-netzteil-dauer","name":"Max. output current at min. output voltage","tableValue":null,"type":"decimal","uom":"[A]","value":"20","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_ausgangsstrom-max-ausgangssp-max-netzteil-dauer","keyOrName":"at_ausgangsstrom-max-ausgangssp-max-netzteil-dauer","name":"Max. output current at max. output voltage","tableValue":null,"type":"decimal","uom":"[A]","value":"17.1","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_ausgangsstrom-max-ausgangssp-min-netzteil-kurz","keyOrName":"at_ausgangsstrom-max-ausgangssp-min-netzteil-kurz","name":"Max. output current peak at min. output voltage","tableValue":null,"type":"decimal","uom":"[A]","value":"24","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_ausgangsstrom-max-ausgangssp-max-netzteil-kurz","keyOrName":"at_ausgangsstrom-max-ausgangssp-max-netzteil-kurz","name":"Max. output current peak at max. output voltage","tableValue":null,"type":"decimal","uom":"[A]","value":"20.6","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_ausgangsleistung-netzteil-dauer","keyOrName":"at_ausgangsleistung-netzteil-dauer","name":"Output power (permanent)","tableValue":null,"type":"decimal","uom":"[W]","value":"480","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_ausgangsleistung-netzteil-kurz","keyOrName":"at_ausgangsleistung-netzteil-kurz","name":"Output power (peak)","tableValue":null,"type":"decimal","uom":"[W]","value":"576","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_ausgangsleistung-netzteil-kurz-zusatz","keyOrName":"at_ausgangsleistung-netzteil-kurz-zusatz","name":"Note on output power (peak)","tableValue":[[["td","≤ 45 °C permitted continuously; > 45 °C < 1 minute every 10 minutes "]]],"type":"text-table","uom":"[W]","value":null,"valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_leistungsfaktor-netzteil-120vac","keyOrName":"at_leistungsfaktor-netzteil-120vac","name":"Power factor (nominal voltage 120 V AC / 60 Hz)","tableValue":null,"type":"decimal","uom":"","value":"0.99","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_leistungsfaktor-netzteil-230vac","keyOrName":"at_leistungsfaktor-netzteil-230vac","name":"Power factor (nominal voltage 230 V AC / 50 Hz)","tableValue":null,"type":"decimal","uom":"","value":"0.95","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_leistungsreserve-netzteil-prozent","keyOrName":"at_leistungsreserve-netzteil-prozent","name":"Power reserve","tableValue":null,"type":"string","uom":"[%]","value":"20","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_anzahl-ausgangsstromkreise","keyOrName":"at_anzahl-ausgangsstromkreise","name":"Number of output circuits","tableValue":null,"type":"integer","uom":"","value":"1","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_restwelligkeit-netzteil-max-millivolt","keyOrName":"at_restwelligkeit-netzteil-max-millivolt","name":"Max. residual ripple","tableValue":null,"type":"decimal","uom":"[mV]","value":"50","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_einschaltspitzenstrom-netzteil-120vac","keyOrName":"at_einschaltspitzenstrom-netzteil-120vac","name":"Switch-on peak current (nominal voltage 120 V AC / 60 Hz)","tableValue":null,"type":"decimal","uom":"[A]","value":"9","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_einschaltspitzenstrom-netzteil-230vac","keyOrName":"at_einschaltspitzenstrom-netzteil-230vac","name":"Switch-on peak current (nominal voltage 230 V AC / 50 Hz)","tableValue":null,"type":"decimal","uom":"[A]","value":"7","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_einschaltstrombegrenzung-netzteil","keyOrName":"at_einschaltstrombegrenzung-netzteil","name":"Inrush current limitation","tableValue":null,"type":"string","uom":"","value":"yes","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_wirkungsgrad-netzteil-120vac","keyOrName":"at_wirkungsgrad-netzteil-120vac","name":"Efficiency (nominal voltage 120 V AC / 60 Hz)","tableValue":null,"type":"decimal","uom":"[%]","value":"92.7","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_wirkungsgrad-netzteil-230vac","keyOrName":"at_wirkungsgrad-netzteil-230vac","name":"Efficiency (nominal voltage 230 V AC / 50 Hz)","tableValue":null,"type":"decimal","uom":"[%]","value":"94","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_externe-eingangsabsicherung-netzteil","keyOrName":"at_externe-eingangsabsicherung-netzteil","name":"External input protection","tableValue":null,"type":"string","uom":"","value":"≥ B-10 A / ≥ C-10 A","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_derating-netzteil","keyOrName":"at_derating-netzteil","name":"Derating","tableValue":null,"type":"string","uom":"[W/K]","value":"12 (60...70 °C)","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_netzausfallueberbrueckungszeit-netzteil-120vac","keyOrName":"at_netzausfallueberbrueckungszeit-netzteil-120vac","name":"Mains buffering time (nominal voltage 120 V AC / 60 Hz)","tableValue":null,"type":"decimal","uom":"[ms]","value":"26","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_netzausfallueberbrueckungszeit-netzteil-230vac","keyOrName":"at_netzausfallueberbrueckungszeit-netzteil-230vac","name":"Mains buffering time (nominal voltage 230 V AC / 50 Hz)","tableValue":null,"type":"decimal","uom":"[ms]","value":"26","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_eingangsstrom-netzteil-120vac","keyOrName":"at_eingangsstrom-netzteil-120vac","name":"Input current (nominal voltage 120 V AC / 60 Hz)","tableValue":null,"type":"decimal","uom":"[A]","value":"4.36","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_eingangsstrom-netzteil-230vac","keyOrName":"at_eingangsstrom-netzteil-230vac","name":"Input current (nominal voltage 230 V AC / 50 Hz)","tableValue":null,"type":"decimal","uom":"[A]","value":"2.33","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_verlustleistung-netzteil-120vac","keyOrName":"at_verlustleistung-netzteil-120vac","name":"Power loss (nominal voltage 120 V AC / 60 Hz)","tableValue":null,"type":"decimal","uom":"[W]","value":"37.8","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_verlustleistung-netzteil-230vac","keyOrName":"at_verlustleistung-netzteil-230vac","name":"Power loss (nominal voltage 230 V AC / 50 Hz)","tableValue":null,"type":"decimal","uom":"[W]","value":"30.6","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_rueckspeisefestigkeit-netzteil","keyOrName":"at_rueckspeisefestigkeit-netzteil","name":"Back feeding protection","tableValue":null,"type":"decimal","uom":"[V]","value":"35","valueList":null}],"name":""}],"sectionName":"Electrical data"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_ausgaenge-kurzschlussfest","keyOrName":"at_ausgaenge-kurzschlussfest","name":"Short-circuit proof","tableValue":null,"type":"string","uom":"","value":"yes","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_ausgaenge-ueberlastfest","keyOrName":"at_ausgaenge-ueberlastfest","name":"Overload protection","tableValue":null,"type":"string","uom":"","value":"yes","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_ausgang-ueberlastverhalten","keyOrName":"at_ausgang-ueberlastverhalten","name":"Overload performance","tableValue":null,"type":"string","uom":"","value":"Hiccup Mode; in the event of overload / short circuit, the output alternately supplies continuous power for 2 s and then switches off for 18 s","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_ausfuehrung-dcok-signal-netzteil","keyOrName":"at_ausfuehrung-dcok-signal-netzteil","name":"Type DC-OK signal","tableValue":null,"type":"string","uom":"","value":"Relay output","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_werte-dcok-signal-netzteil","keyOrName":"at_werte-dcok-signal-netzteil","name":"Reliability of the DC OK signal","tableValue":null,"type":"string","uom":"","value":"60 V DC (0.3 A) / 30 V DC (1 A) / 30 V AC (0.5 A)","valueList":null}],"name":""}],"sectionName":"Outputs"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_umgebungstemperatur-cel-bereich","keyOrName":"at_umgebungstemperatur-cel-bereich","name":"Ambient temperature","tableValue":null,"type":"string","uom":"[°C]","value":"-25...70","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_umgebungstemperatur-zusatz","keyOrName":"at_umgebungstemperatur-zusatz","name":"Note on ambient temperature","tableValue":[[["td","observe the free space for convection (see operating instructions) "]]],"type":"text-table","uom":"","value":null,"valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_lagertemperatur-cel-bereich","keyOrName":"at_lagertemperatur-cel-bereich","name":"Storage temperature","tableValue":null,"type":"string","uom":"[°C]","value":"-40...85","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_max-luftfeuchtigkeit","keyOrName":"at_max-luftfeuchtigkeit","name":"Max. relative air humidity","tableValue":null,"type":"string","uom":"[%]","value":"95;  (IEC 60068-2-30)","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_schutzart","keyOrName":"at_schutzart","name":"Protection","tableValue":null,"type":"string","uom":"","value":"IP 20;  (EN 60529)","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_verschmutzungsgrad","keyOrName":"at_verschmutzungsgrad","name":"Pollution degree","tableValue":null,"type":"string","uom":"","value":"2;  (IEC 62103: conductive soiling not permitted)","valueList":null}],"name":""}],"sectionName":"Operating conditions"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_emv","keyOrName":"at_emv","name":"EMC","tableValue":[[["td","EN 61000-6-1"],["td",""]],[["td","EN 61000-6-2"],["td",""]],[["td","EN 61000-6-3"],["td",""]],[["td","EN 61000-6-4"],["td",""]],[["td","EN 61000-3-2"],["td","class A"]]],"type":"text-table","uom":"","value":null,"valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_schwingfestigkeit","keyOrName":"at_schwingfestigkeit","name":"Vibration resistance","tableValue":[[["td","IEC 60068-2-6"],["td","±1,6 mm 2...17,8 Hz / 2 g 17,8...500 Hz"]]],"type":"text-table","uom":"","value":null,"valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_schockfestigkeit","keyOrName":"at_schockfestigkeit","name":"Shock resistance","tableValue":[[["td","IEC 60068-2-27"],["td","30 g 6 ms / 20 g 11 ms"]]],"type":"text-table","uom":"","value":null,"valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_mttf","keyOrName":"at_mttf","name":"MTTF","tableValue":null,"type":"decimal","uom":"[years]","value":"53","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_leistungsfaktorkorrektur-pfc","keyOrName":"at_leistungsfaktorkorrektur-pfc","name":"Power Factor Correction (PFC)","tableValue":null,"type":"string","uom":"","value":"met","valueList":null}],"name":""}],"sectionName":"Tests / approvals"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_erp-bruttogewicht-wert","keyOrName":"at_erp-bruttogewicht-wert","name":"Weight","tableValue":null,"type":"decimal","uom":"[g]","value":"1133.35","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_gehaeuse","keyOrName":"at_gehaeuse","name":"Housing","tableValue":null,"type":"string","uom":"","value":"rectangular","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_montageart","keyOrName":"at_montageart","name":"Type of mounting","tableValue":null,"type":"string","uom":"","value":"Mounting on DIN rail;  (TH35 (EN 60715))","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_dimensions","keyOrName":"at_dimensions","name":"Dimensions","tableValue":null,"type":"string","uom":"[mm]","value":"124 x 65 x 132.5","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_werkstoffe-gehaeuse-text","keyOrName":"at_werkstoffe-gehaeuse-text","name":"Material","tableValue":null,"type":"string","uom":"","value":"housing: steel sheet","valueList":null}],"name":""}],"sectionName":"Mechanical data"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_anzeige","keyOrName":"at_anzeige","name":"Display","tableValue":[[["td","DCok"],["td","1 x LED"]]],"type":"text-table","uom":"","value":null,"valueList":null}],"name":""}],"sectionName":"Displays / operating elements"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_bemerkungen","keyOrName":"at_bemerkungen","name":"Remarks","tableValue":[[["td"," series connection of outputs only applies to identical units up to max. 150 V DC overall voltage"]]],"type":"text-table","uom":"","value":null,"valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_verpackungseinheit","keyOrName":"at_verpackungseinheit","name":"Pack quantity","tableValue":null,"type":"string","uom":"","value":"1 pcs.","valueList":null}],"name":""}],"sectionName":"Remarks"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":null,"inlineImageUrl":null,"key":"attachable connection","keyOrName":"attachable connection","name":"screw terminals","tableValue":null,"type":"String","uom":"","value":"","valueList":null}],"name":null}],"sectionName":"Electrical connection"}],"diagramSections":[{"diagrams":[{"caption":[],"diagramPath":"https://media.ifm.com/dam/d7e25ca6-57e9-447e-ab6b-e8706ace837d/pim/PIC_0032.png","header":"Block diagram"},{"caption":[[["td","1:"],["td","Output curve"]],[["td","2:"],["td","Hiccup Mode"]]],"diagramPath":"https://media.ifm.com/dam/e003c76c-0361-4fde-b2c4-37c860ae8fa1/pim/PIC_0083.png","header":"Output curve"},{"caption":[],"diagramPath":"https://media.ifm.com/dam/2b5fa230-1afc-4e3a-bd54-819fd98150a6/pim/PIC_0044.png","header":"Characteristic curve for degree of efficiency / power loss"},{"caption":[],"diagramPath":"https://media.ifm.com/dam/300bb91b-072c-4d95-9c40-4be3db3abd10/pim/PIC_0058.png","header":"Characteristic curve for derating"},{"caption":[],"diagramPath":"https://media.ifm.com/dam/b8720525-479a-4f81-89c4-5f49d0424a43/pim/PIC_0072.png","header":"Characteristic curve for mains buffering time"}],"sectionName":"Diagrams and graphs"}],"footerAddress":"ifm efector, inc. • 1100 Atwater Drive • Malvern • PA 19355","footerDate":null,"footerRemark":"We reserve the right to make technical alterations without prior notice.","freeTableSection":null,"infoBox":[],"lastModified":"Thu Oct 15 02:36:57 CEST 2026","madeInRemark":"","scaleDrawingLegend":[[["td","1"],["td","potentiometer 24...28 V DC"]],[["td","2"],["td","LED DCok"]],[["td","3"],["td","terminals DCok Output"]]],"scaleDrawingRef":"https://media.ifm.com/dam/a526daea-937d-4370-ab0e-4026f8db85fd/pim,w_0.9;r_pad,w_2000,h_1.01,bc_white/P_MZ_E200_0066.png"},"defaultPdfDatasheetUrl":"https://media.ifm.com/dam/3acd0ebd-f69e-44cc-9a32-cc1dc0511156/Original/DN4014-00_EN-US.pdf","scaleDrawingUrl":"https://media.ifm.com/dam/a526daea-937d-4370-ab0e-4026f8db85fd/pim,w_0.9;r_pad,w_2000,h_1.01,bc_white/P_MZ_E200_0066.png"}