{"datasheetResultDocument":{"certificateImages":{"cul":"/responsive/original/content/gallery/productcertificates/cul.png?v=-2057296668"},"completeFooter":"ifm efector, inc. • 1100 Atwater Drive • Malvern • PA 19355 — We reserve the right to make technical alterations without prior notice. — EN-US — AC5010-00 — 09.02.2005","connections":[{"anschlussbelegungSubSections":[],"beschaltungSubSections":[],"connectionDescriptionAttachable":"contact pins in module upper part : ","connectionDescriptionCable":"","connectionDescriptionPlug":"","connectionSubSectionList":[],"pinLayoutImage":"","pinLayoutImageDesc":"","pinLayoutImageUrl":null,"pinSubSections":[],"sectionName":"Electrical connection"}],"datasheetSections":[{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_betriebsspannung","keyOrName":"at_betriebsspannung","name":"Operating voltage","tableValue":null,"type":"string","uom":"[V]","value":"26.5...31.6 DC","valueList":null}],"name":""}],"sectionName":"Electrical data"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_elektrische-ausfuehrung","keyOrName":"at_elektrische-ausfuehrung","name":"Electrical design","tableValue":null,"type":"string","uom":"","value":"AS-i","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_kontaktbelastbarkeit","keyOrName":"at_kontaktbelastbarkeit","name":"Contact rating","tableValue":null,"type":"string","uom":"","value":"< 2 A","valueList":null}],"name":""}],"sectionName":"Outputs"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_umgebungstemperatur-cel-bereich","keyOrName":"at_umgebungstemperatur-cel-bereich","name":"Ambient temperature","tableValue":null,"type":"string","uom":"[°C]","value":"-25...85","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_schutzart","keyOrName":"at_schutzart","name":"Protection","tableValue":null,"type":"string","uom":"","value":"IP 67;  (depending on the upper part used: IP 20 / IP 65 / IP 67)","valueList":null}],"name":""}],"sectionName":"Operating conditions"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_asi-adressierung","keyOrName":"at_asi-adressierung","name":"AS-i addressing","tableValue":null,"type":"string","uom":"","value":"Addressing socket","valueList":null}],"name":""}],"sectionName":"AS-i classification"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_erp-bruttogewicht-wert","keyOrName":"at_erp-bruttogewicht-wert","name":"Weight","tableValue":null,"type":"decimal","uom":"[g]","value":"59.5","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_gehaeuse","keyOrName":"at_gehaeuse","name":"Housing","tableValue":null,"type":"string","uom":"","value":"rectangular","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_montageart","keyOrName":"at_montageart","name":"Type of mounting","tableValue":null,"type":"string","uom":"","value":"Mounting on DIN rail and panel","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_dimensions","keyOrName":"at_dimensions","name":"Dimensions","tableValue":null,"type":"string","uom":"[mm]","value":"45 x 80 x 20","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_werkstoffe-gehaeuse-text","keyOrName":"at_werkstoffe-gehaeuse-text","name":"Material","tableValue":null,"type":"string","uom":"","value":"housing: PBT","valueList":null}],"name":""}],"sectionName":"Mechanical data"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_verpackungseinheit","keyOrName":"at_verpackungseinheit","name":"Pack quantity","tableValue":null,"type":"string","uom":"","value":"1 pcs.","valueList":null}],"name":""}],"sectionName":"Remarks"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":null,"inlineImageUrl":null,"key":"attachable connection","keyOrName":"attachable connection","name":"contact pins in module upper part","tableValue":null,"type":"String","uom":"","value":"","valueList":null}],"name":null}],"sectionName":"Electrical connection"}],"diagramSections":[],"footerAddress":"ifm efector, inc. • 1100 Atwater Drive • Malvern • PA 19355","footerDate":null,"footerRemark":"We reserve the right to make technical alterations without prior notice.","freeTableSection":null,"infoBox":[],"lastModified":"Thu Aug 13 19:33:31 CEST 2026","madeInRemark":"","scaleDrawingLegend":[[["td","1"],["td","contact pins"]],[["td","2"],["td","panel for labelling"]],[["td","3"],["td","Addressing socket"]]],"scaleDrawingRef":"https://media.ifm.com/dam/1e8b5d6f-ed84-4ae5-a039-cd8eac2c5383/Original/P_MZ_MZ_AC5010MZ.jpg"},"defaultPdfDatasheetUrl":"https://media.ifm.com/dam/6d620f52-bd3a-48ed-bb43-3fbfcb4bfd13/Original/AC5010-00_EN-US.pdf","scaleDrawingUrl":"https://media.ifm.com/dam/1e8b5d6f-ed84-4ae5-a039-cd8eac2c5383/Original/P_MZ_MZ_AC5010MZ.jpg"}