  • Reliable optical distance measurement with high ranges up to 10 m
  • Two switching outputs, one of them programmable as analogue output
  • Scalable measuring range and window function
  • Use in applications with background suppression
  • Excellent price/performance ratio
When selecting an alternative article and accessories please note that technical data may differ!
  • ce
  • ukca
  • cul
  • iolink
Product characteristics
Laser protection class 2
Housing rectangular
Electrical data
Operating voltage [V] 18...30 DC; ("supply class 2" to cULus)
Current consumption [mA] < 150
Protection class III
Reverse polarity protection yes
Typ. lifetime [h] 50000
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Outputs
Total number of outputs 2
Electrical design PNP
Number of digital outputs 2
Output function normally open / normally closed; (parameterisable)
Max. current load per output [mA] 200
Number of analogue outputs 1
Analogue current output [mA] 4...20; (IEC 61131-2)
Max. load [Ω] 250
Analogue voltage output [V] 0...10; (IEC 61131-2)
Min. load resistance [Ω] 5000
Short-circuit protection yes
Type of short-circuit protection pulsed
Overload protection yes
Detection zone
Max. light spot width [mm] 15
Max. light spot height [mm] 15
Light spot dimensions refer to 10 m
Background suppression [m] 0...19
Measuring/setting range
Measuring range [m] 0.2...10; (white paper 200 x 200 mm 90% remission)
Sampling rate [Hz] 1...50
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
Profiles Smart Sensor: Sensor Identification; Binary Data Channel; Process Value; Sensor Diagnosis
SIO mode yes
Required master port type A
Process data analogue 2
Process data binary 3
Min. process cycle time [ms] 6
Supported DeviceIDs
Type of operation DeviceID
default 806
Operating conditions
Ambient temperature [°C] -10...60
Protection IP 67
Tests / approvals
EMC
EN 60947-5-2
Laser protection class 2
Notes on laser protection
Caution: laser light
Power: <= 4 mW
Wave length: 650 nm
pulse: 1,3 ns
Do not stare into beam.
Avoid exposure to the laser light.
laser class: 2
EN / IEC60825-1:2007
EN / IEC60825-1:2014
Complies with 21 CFR 1040 except for deviations pursuant to Laser Notice No. 50, dated June 2007.
MTTF [years] 182
Mechanical data
Weight [g] 243.5
Housing rectangular
Dimensions [mm] 59 x 42 x 52
Materials housing: diecast zinc; front pane: glass; LED window: PC
Lens alignment side lens
Displays / operating elements
Display
switching status 2 x LED, yellow
operation LED, green
distance value, programming alphanumeric display, 4-digit
Accessories
Accessories (optional)
Protective cover, E21133
Remarks
Remarks
For more information about the measuring range / application please refer to the operating instructions.
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; coding: A
Other data
Parameter Setting range Factory setting
Uni mm, m, inch mm
OU1 Hno, Hnc, Fno, Fnc Hno
SP1 [mm] 200...9999 1000
nSP1 [mm] 200...9999 800
FSP1 [mm] 200...9999 1200
OU2 Hno, Hnc, Fno, Fnc, I, U I
SP2 [mm] 200...9999 2000
nSP2 [mm] 200...9999 1800
FSP2 [mm] 200...9999 2200
ASP [mm] 0...9999 0
AEP [mm] 0...9999 9999
rATE [Hz] 1...50 50
dS1 [s] 0...0.1...5 0
dr1 [s] 0...0.1...5 0
dS2 [s] 0...0.1...5 0
dr2 [s] 0...0.1...5 0
dFo [s] 0...0.1...5 0
dIS d1...3 ; rd1...3; OFF d3
repeatability/accuracy
read/write distance (mm) repeatability of the measured values accuracy
white (90 % remission) grey (18 % remission) white (90 % remission) grey (18 % remission)
200...1000 mm ± 5.0 mm ±7.5 mm ± 15.0 mm ± 18.0 mm
1000...2000 mm ± 5.5 mm ±10.0 mm ± 15.0 mm ± 20.0 mm
2000...4000 mm ± 17.5 mm ±22.5 mm ± 25.0 mm ± 32.0 mm
4000...6000 mm ± 27.5 mm ±40.0 mm ± 35.0 mm ± 50.0 mm
6000...10000 mm ± 60.0 mm ± 70.0mm
Sampling rate 50 Hz
Extraneous light on the object < 40 klx
repeatability/accuracy
read/write distance (mm) repeatability of the measured values accuracy
white (90 % remission) grey (18 % remission) white (90 % remission) grey (18 % remission)
200...1000 mm ± 16.5 mm ±16.5 mm ± 26.5 mm ± 26.5 mm
1000...2000 mm ± 16.5 mm ±16.5 mm ± 26.5 mm ± 26.5 mm
2000...4000 mm ± 30.0 mm ±37.0 mm ± 40.0 mm ± 47.0 mm
4000...6000 mm ± 37.0 mm ±57.0 mm ± 47.0 mm ± 67.0 mm
6000...10000 mm ± 75.0 mm ± 85.0mm
Sampling rate 50 Hz
Extraneous light on the object 40...100 klx
repeatability/accuracy
read/write distance (mm) repeatability of the measured values accuracy
white (90 % remission) grey (18 % remission) white (90 % remission) grey (18 % remission)
200...1000 mm ± 4.0 mm ±4.5 mm ± 14.0 mm ± 15.0 mm
1000...2000 mm ± 4.5 mm ±6.0 mm ± 14.5 mm ± 16.0 mm
2000...4000 mm ± 13.5 mm ±14.5 mm ± 23.5 mm ± 24.0 mm
4000...6000 mm ± 19.0 mm ±21.0 mm ± 29.0 mm ± 31.0 mm
6000...10000 mm ± 37.0 mm ± 47.0mm
Sampling rate 1 Hz
Extraneous light on the object < 40 klx
repeatability/accuracy
read/write distance (mm) repeatability of the measured values accuracy
white (90 % remission) grey (18 % remission) white (90 % remission) grey (18 % remission)
200...1000 mm ± 10.0 mm ± 10.0 mm ± 20.0 mm ± 20.0 mm
1000...2000 mm ± 10.0 mm ± 10.0 mm ± 20.0 mm ± 20.0 mm
2000...4000 mm ± 17.0 mm ± 18.0 mm ± 27.0 mm ± 28.0 mm
4000...6000 mm ± 22.0 mm ± 25.0 mm ± 32.0 mm ± 35.0 mm
6000...10000 mm ± 37.0 mm ± 47.0mm
Sampling rate 1 Hz
Extraneous light on the object < 40...100 klx
- -
Range on black object (6 % remission) <= 4000 mm
- -
The values apply at
constant ambient conditions 23 °C / 960 hPa