You probably do not come from: New Zealand. If necessary, change to: United States
  1. Products
  2. IO-Link
  3. IO-Link accessories / connection technology
  4. IO-Link accessories
  5. E30444

IO-Link repeater

E30444

IO-LINK REPEATER

IO-Link repeater

E30444

IO-LINK REPEATER

  • IO-Link range increased up to 240 m
  • Series connection of max. 3 repeaters possible
  • Easy set-up with "plug & play"
  • Use in the food and beverage industry
  • Easy integration into each IO-Link structure
  • Transparent_fuer_alle_zertifizierten_IO_Link_Master|
  • ce
  • ukca
  • cul
Application
Special feature Gold-plated contacts
Electrical data
Operating voltage [V] 18...30 DC
Nominal voltage DC [V] 24
Current consumption [mA] < 20
Protection class III
Reverse polarity protection yes; (on the master side)
Overvoltage protection yes; (integrated)
Surge protection for voltage
between L-, pin 5 and ground between L+, signal cables and ground
Umax = 45 V for surge Umax = 90 V for surge
Umin = 30 V for normal operation Umin = 60 V for normal operation
Surge protection for current
surge current leakage current
Imax = 25 A Imax = 10 µ
Power-on delay time [s] < 2; (per repeater)
Current rating per port [A] 0.84; (Port Class A; Port Class B: 2)
Delay time acyclic data up to 2 cycles; (per repeater)
Delay time process data up to 1 cycle; (per repeater)
Interfaces
Communication interface IO-Link
Unterstützte IO-Link Revision 1.0; 1.1
Unterstützte Masterportklasse A / B
Transmission type COM1 (4,8 kBaud); COM2 (38,4 kBaud); COM3 (230,4 kBaud)
SDCI standard IEC 61131-9
SIO mode no
Operating conditions
Ambient temperature [°C] -25...65
Storage temperature [°C] -40...85
Protection IP 68; IP 69K; (7 days / 3 m water depth / 0.3 bar: IP 68)
Tests / approvals
EMC
DIN EN 61000-6-2
DIN EN 61000-6-4 in plastic or open metal tanks
Shock resistance
DIN EN 60068-2-27 50 g (11 ms)
Vibration resistance
DIN EN 60068-2-6 20 g (10...2000 Hz)
MTTF [years] 409
UL approval
File number UL E205959
Mechanical data
Weight [g] 212
Materials stainless steel (1.4404 / 316L); PEI; PA reinforced fibre; FKM; Grounding clamp: stainless steel (1.4301 / 304)
Displays / operating elements
Display
1 x LED
operation green
IO-Link green
fault red
Remarks
Remarks
For information on the maximum cable length please refer to the operating instructions.
functional grounding via premounted grounding clamp
for further information please see the operating instructions
Pack quantity 1 pcs.