For proper operation, some guidelines must be followed.
Preferable mounting is just before or in a vertical pipe with flow going up to ensure a full pipe. When installed in a horizontal pipe, install the sensor at a maximum of 45° from horizontal to avoid the influence of air bubbles or deposits.
The measurement channel of the LDL200 must be installed parallel to the direction of flow. An alignment mark is laser etched on the body of the sensor indicating the correct orientation in the pipe.
Pipe size | ![]() LDL100 |
![]() LDL200 |
---|---|---|
1" | ![]() E43310 weld fitting |
Not recommended * |
1-1/2" | Not recommended * | |
2" | ![]() E30130 weld fitting ![]() E33208 1.5" triclamp fitting ![]() E33209 2" triclamp fitting |
|
2-1/2" | ||
3" | ||
4" | ||
> 4" |
* Due to the length of the tip and location of the measuring channel, LDL200 cannot be used for pipe size under 2”