Product characteristics |
Number of inputs and outputs |
Number of digital outputs: 1 |
Process connection |
M18 x 1,5 internal thread |
Application |
Media |
Liquids; Gases; aggressive media |
Medium temperature [°C] |
-25...80 |
Pressure rating [bar] |
300 |
Liquids |
Medium temperature [°C] |
-25...80 |
Gases |
Medium temperature [°C] |
-25...80 |
Electrical data |
Operating voltage tolerance [%] |
-5...10 |
Operating voltage [V] |
85...265 AC |
Nominal voltage AC [V] |
< 240 |
Protection class |
II |
Reverse polarity protection |
no |
Power-on delay time [s] |
15; (optically indicated) |
Inputs / outputs |
Number of inputs and outputs |
Number of digital outputs: 1 |
Outputs |
Total number of outputs |
1 |
Output signal |
switching signal |
Electrical design |
relay |
Number of digital outputs |
1 |
Output function |
normally open / normally closed; (parameterisable) |
Contact rating |
3 A (250 V AC / 30 V DC); (number of switching cycles: 20 million mechanically; switching cycles at 3 A load: 100,000 electrical; type of switch-off: normally open) |
Short-circuit proof |
no |
Overload protection |
no |
Measuring/setting range |
Probe length L [mm] |
45 |
Liquids |
Setting range [cm/s] |
3...300 |
Greatest sensitivity [cm/s] |
3...60 |
Gases |
Setting range [cm/s] |
200...3000 |
Greatest sensitivity [cm/s] |
200...800 |
Accuracy / deviations |
Temperature gradient [K/min] |
300 |
Response times |
Response time [s] |
1...10 |
Liquids |
Response time [s] |
1...10 |
Gases |
Response time [s] |
1...10 |
Software / programming |
Adjustment of the switch point |
pushbutton |
Operating conditions |
Ambient temperature [°C] |
-25...80 |
Protection |
IP 67 |
Tests / approvals |
Shock resistance |
DIN IEC 68-2-27 |
50 g (11 ms) |
|
Vibration resistance |
DIN EN 60068-2-6 |
20 g (55...2000 Hz) |
|
MTTF [years] |
224 |
Mechanical data |
Weight [g] |
254.4 |
Dimensions [mm] |
M18 x 1.5 |
Thread designation |
M18 x 1.5 |
Materials |
PBT-GF20 |
Materials (wetted parts) |
titanium (3.7035); O-ring: FFKM 8 x 1,5 |
Process connection |
M18 x 1,5 internal thread |
Displays / operating elements |
Display |
function |
10 x LED, three-colour |
|
Electrical connection |
Required protection |
miniature fuse to IEC60127-2 sheet 1; ≤ 5 A; fast acting |
Remarks |
Remarks |
Recommendation Check the safe functioning of the unit after a short circuit. |
|
Pack quantity |
1 pcs. |
Electrical connection |
Connection |
Connector: 1 x 1/2" |