You probably do not come from: Namibia. If necessary, change to: United States
  1. Products
  2. Sensors
  3. Cylinder sensors
  4. All cylinder sensors
  5. MR0902

T-slot cylinder sensor with reed contact

MR0902

MRI3021-BKOA/R/AS

T-slot cylinder sensor with reed contact

MR0902

MRI3021-BKOA/R/AS

  • Self-locking fixture for quick mounting and easy adjustment
  • Easy fit 'drop from the top' into a slot
  • Fast wiring due to integrated M8 connector
  • With combined AC/DC output and two-wire technology
  • Very high switching frequency
  • ccc
  • ce
  • ukca
  • cul
Product characteristics
Electrical design PNP
Output function normally open
Dimensions [mm] 27.5 x 18 x 15.5
Electrical data
Operating voltage [V] 5...50 AC / 5...60 DC; (cULus supply class 2: 5...30 AC / 5...60 DC)
Protection class III
Reverse polarity protection yes
Reverse polarity protection yes
Outputs
Electrical design PNP
Output function normally open
Max. voltage drop switching output DC [V] 2.5
Max. voltage drop switching output AC [V] 2.5
Permanent current rating of switching output AC [mA] 350
Permanent current rating of switching output DC [mA] 500
Switching frequency AC [Hz] 1000
Switching frequency DC [Hz] 1000
Max. switching power [W] 10
Short-circuit protection no
Short-circuit proof no
Overload protection no
Detection zone
Response sensitivity [mT] 2.1
Travel speed [m/s] 10
Accuracy / deviations
Hysteresis [mm] 1
Repeatability [mm] < 0.2
Response times
Max. fall time [ms] 0.1
Max. make time incl. bounce [ms] 0.6
Operating conditions
Ambient temperature [°C] -25...70
Protection IP 65; IP 67
Tests / approvals
EMC
EN 61000-4-2 ESD - CD / 8 kV AD
EN 61000-4-3 HF radiated 10 V/m
EN 61000-4-4 Burst 2 kV
EN 61000-4-5 Surge 0,5 kV line to line, Ri: 2 Ohm
EN 61000-4-6 HF conducted 10 V
EN 55011 class B
MTTF [years] 17837
Mechanical data
Weight [g] 12.4
Mounting non-flush mountable
Type of mounting fixing element with combined head slot / hexagon socket AF 1.5
Cylinder type T-slot cylinders
Dimensions [mm] 27.5 x 18 x 15.5
Materials housing: PA; Fixing element: stainless steel / brass
Switching cycles when connected to PLC [Mio] < 40
Displays / operating elements
Display
switching status 1 x LED, yellow
Electrical connection
Required protection miniature fuse to IEC60127-2 sheet 1; ≤ 0,175 A; fast acting
Accessories
Items supplied
rubber placeholder: 1
Remarks
Remarks
Recommendation: Check the safe functioning of the unit after a short circuit.
operating voltage "supply class 2" according to cULus
Pack quantity 1 pcs.
Electrical connection - plug
Connector: 1 x M8; coding: A; Locking: snap-fit