You probably do not come from: Namibia. If necessary, change to: United States
  1. Products
  2. Sensors
  3. Inductive sensors
  4. All inductive sensors
  5. IM507A

Inductive sensor

IM507A

IME3040-FPKG/3D

Inductive sensor

IM507A

IME3040-FPKG/3D

  • For applications in hazardous areas
  • Long sensing range for use in conveying
  • Output function normally open / normally closed programmable
  • Robust housing for use in harsh industrial environments
  • Five positions of the sensing face selectable
phase-out article
Alternative articles: IM510A Product comparison: IM507A / IM510A When selecting an alternative article and accessories please note that technical data may differ!
  • ce
  • ex
Product characteristics
Output function normally open / normally closed; (selectable)
Sensing range [mm] 40
Housing rectangular
Dimensions [mm] 40 x 40 x 105
Electrical data
Operating voltage [V] 10...30 DC
Current consumption [mA] < 15
Protection class III
Reverse polarity protection yes
Outputs
Output function normally open / normally closed; (selectable)
Max. voltage drop switching output DC [V] 2.5
Max. leakage current [mA] 0.5
Permanent current rating of switching output DC [mA] 200
Switching frequency DC [Hz] 100
Short-circuit proof yes
Overload protection yes
Detection zone
Sensing range [mm] 40
Real sensing range Sr [mm] 40 ± 10 %
Operating distance [mm] 0...32.4
Accuracy / deviations
Correction factor steel: 1 / stainless steel: 0.7 / brass: 0.4 / aluminium: 0.3 / copper: 0.2
Hysteresis [% of Sr] 1...20
Switch point drift [% of Sr] -10...10
Operating conditions
Ambient temperature [°C] -20...60
Protection IP 65; IP 67
Tests / approvals
ATEX marking II 3D Ex tc IIIC T95°C Dc X
EMC
EN 60947-5-2
MTTF [years] 1401
Mechanical data
Weight [g] 249.5
Housing rectangular
Mounting non-flush mountable
Dimensions [mm] 40 x 40 x 105
Materials PC; PA; stainless steel
Displays / operating elements
Display
switching status 1 x LED, yellow
Remarks
Remarks
Recommendation: Check the safe functioning of the unit after a short circuit.
5 positions of the active zone possible
Pack quantity 1 pcs.
Electrical connection
Connection terminals: 0.34...1.5 mm²; Cable sheath: Ø 5...9 mm