Product characteristics |
Housing |
housing for DIN rail mounting |
Dimensions [mm] |
78 x 45 x 124.7 |
Application |
Application |
pulse evaluation system with microprocessor for direction monitoring with separate direction indication for "right" and "left" |
Electrical data |
Nominal voltage AC [V] |
110...240 |
Nominal voltage DC [V] |
27 |
Nominal voltage tolerance [%] |
< 10 |
Nominal voltage tolerance 2 [%] |
20...10 |
Nominal frequency AC [Hz] |
50...60 |
Power consumption [W] |
3 |
Auxiliary energy for sensors DC [V] |
19.6...27.7; (SELV, ≤ 150 mA) |
Inputs / outputs |
Number of inputs and outputs |
Number of relay outputs: 2 |
Outputs |
Number of relay outputs |
2 |
Contact rating |
6 A (250 V AC); B300, R300 |
Operating conditions |
Ambient temperature [°C] |
-40...60 |
Storage temperature [°C] |
-40...85 |
Max. relative air humidity [%] |
80; (40 °C: 50 %) |
Protection |
IP 50 |
Protection rating terminals |
IP 20 |
Tests / approvals |
EMC |
EN 61010 |
2011 |
EMV 89/336/EWG |
|
EN 61000-6-2 |
2005 |
EN 61000-6-4 |
2007 |
|
Mechanical data |
Weight [g] |
379.5 |
Housing |
housing for DIN rail mounting |
Dimensions [mm] |
78 x 45 x 124.7 |
Materials |
plastics |
Displays / operating elements |
Display |
switching status |
LED, green |
|
OLED display, 128 x 64 luminous |
|
Remarks |
Remarks |
The unit complies with overvoltage category II; degree of soiling 2 |
|
Electrical connection |
|
dual-chamber terminals: 2 x ...2.5 mm²; AWG 14 |