Product characteristics
Electrical design |
AS-i |
Sensing range [mm] |
4 |
Dimensions [mm] |
55 x 60 x 35 |
Electrical data
Operating voltage [V] |
26.5...31.6 DC |
Current consumption [mA] |
160 |
Protection class |
III |
Detection zone
Sensing range [mm] |
4 |
Operating distance target puck [mm] |
74 |
Operating conditions
Ambient temperature [°C] |
-10...50 |
Protection |
IP 5x; (when used outside the hazardous area: IP 67) |
Tests / approvals
ATEX marking |
II 3D Ex tc IIIB T85°Dc IP5X X |
Note on ATEX marking |
only in conjunction with the impact protection housing |
|
EMC |
|
MTTF [years] |
404 |
AS-i classification
AS-i version |
2.1 |
Extended addressing mode |
yes |
AS-i I/O configuration [hex] |
7 |
AS-i ID code [hex] |
A.E |
Mechanical data
Weight [g] |
779.5 |
Dimensions [mm] |
55 x 60 x 35 |
Materials |
housing: PBT orange; cover: PC black; Impact protection housing: stainless steel |
Displays / operating elements
Display |
operation |
1 x LED, green |
function |
1 x LED, yellow |
|
Accessories
Items supplied |
Impact protection housing |
Mounting plate: 1 |
socket head screws: 2 x M5 x 35 |
|
Electrical connection - plug
Elektrischer Anschluss |
Connector: 1 x M12; coding: A; Moulded body: stainless steel |
Electrical connection - socket
Connection |
Connector: 1 x M12; coding: A; Moulded body: stainless steel |