Product characteristics | |||||||
---|---|---|---|---|---|---|---|
Number of inputs and outputs | Number of digital outputs: 2 | ||||||
Factory setting | oils; oil-based media; powder | ||||||
Process connection | threaded connection G 1/2 sealing cone | ||||||
Application | |||||||
Special feature | Gold-plated contacts | ||||||
Media | Liquids; viscous media; powder | ||||||
Cannot be used for | See the operating instructions, chapter "Function and features". | ||||||
Medium temperature [°C] | -20...85 | ||||||
Probe length [mm] | 11 | ||||||
Tank pressure [bar] | -1...40 | ||||||
Electrical data | |||||||
Operating voltage [V] | 18...30 DC | ||||||
Current consumption [mA] | < 50 | ||||||
Protection class | III | ||||||
Reverse polarity protection | yes | ||||||
Measuring principle | capacitive | ||||||
Inputs / outputs | |||||||
Number of inputs and outputs | Number of digital outputs: 2 | ||||||
Outputs | |||||||
Total number of outputs | 2 | ||||||
Output signal | switching signal; IO-Link | ||||||
Electrical design | PNP/NPN | ||||||
Number of digital outputs | 2 | ||||||
Output function | normally open / normally closed; (parameterisable) | ||||||
Max. voltage drop switching output DC [V] | 2.5 | ||||||
Permanent current rating of switching output DC [mA] | 100 | ||||||
Short-circuit protection | yes | ||||||
Type of short-circuit protection | pulsed | ||||||
Overload protection | yes | ||||||
Measuring/setting range | |||||||
Factory setting | oils; oil-based media; powder | ||||||
Response times | |||||||
Response time [s] | < 0.5 | ||||||
Interfaces | |||||||
Communication interface | IO-Link | ||||||
Transmission type | COM2 (38,4 kBaud) | ||||||
IO-Link revision | 1.1 | ||||||
SDCI standard | IEC 61131-9 | ||||||
Profiles | Smart Sensor: Process Data Variable; Device Identification | ||||||
SIO mode | yes | ||||||
Required master port type | A | ||||||
Process data analogue | 1 | ||||||
Process data binary | 2 | ||||||
Min. process cycle time [ms] | 2.3 | ||||||
Supported DeviceIDs |
|
||||||
Operating conditions | |||||||
Ambient temperature [°C] | -20...60 | ||||||
Storage temperature [°C] | -40...85 | ||||||
Protection | IP 67; (when used outside the hazardous area: IP 68 / IP 69) | ||||||
Tests / approvals | |||||||
ATEX marking | |||||||
EMC |
|
||||||
Shock resistance |
|
||||||
Vibration resistance |
|
||||||
MTTF [years] | 223 | ||||||
Mechanical data | |||||||
Weight [g] | 218 | ||||||
Materials | stainless steel (1.4404 / 316L); PEEK; PEI; FKM | ||||||
Materials (wetted parts) | PEEK; surface characteristics: Ra < 0,8 / Rz 4 | ||||||
Process connection | threaded connection G 1/2 sealing cone | ||||||
Displays / operating elements | |||||||
Display |
|
||||||
Remarks | |||||||
Pack quantity | 1 pcs. | ||||||
Electrical connection | |||||||
Connection | Connector: 1 x M12; Contacts: gold-plated | ||||||
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — EN-GB — LMT01A — 23.06.2021 —
![]() |