You probably do not come from: Latvia. If necessary, change to: United States
  1. Products
  2. Sensors
  3. Photoelectric sensors
  4. All photoelectric sensors
  5. OGD250

Photoelectric distance sensor

OGD250

OGDLFCKG/IO-LINK/US

Photoelectric distance sensor

OGD250

OGDLFCKG/IO-LINK/US

  • Small compact design with standard M18 thread and PMD time-of-flight technology
  • Measurement to the nearest millimetre and monitoring of distances in the running process
  • Colour-independent range
  • Simultaneous output of distance value and reflectivity for increased process reliability
  • Convenient operation via buttons or parameter setting via IO-Link
  • ce
  • ukca
  • iolink
  • cul
Product characteristics
Type of light red light
Laser protection class 1
Housing rectangular with M18 thread
Electrical data
Operating voltage [V] 10...30 DC; ("supply class 2" to cULus)
Current consumption [mA] 45; (24 V)
Protection class III
Reverse polarity protection yes
Type of light red light
Wave length [nm] 650
Inputs
Inputs Laser On/ Off
Outputs
Electrical design PNP/NPN; (parameterisable)
Output function 2 x normally open / normally closed; (parameterisable)
Max. current load per output [mA] 100
Short-circuit protection yes
Type of short-circuit protection pulsed
Overload protection yes
Operating mode: FINE
Switching frequency DC [Hz] 20
Operating mode: STD
Switching frequency DC [Hz] 40
Operating mode: FAST
Switching frequency DC [Hz] 60
Detection zone
Max. light spot diameter [mm] 5
Light spot dimensions refer to at maximum range
Background suppression [m] < 20
Measuring/setting range
Setting range object reflectivity [%] 6...900; (reflectivity; 6 % black paper; 100 % white paper)
Operating mode: FINE
Measuring range [m] 0.05...2
Sampling rate [Hz] 60
Operating mode: STD
Measuring range [m] 0.05...2
Sampling rate [Hz] 120
Operating mode: FAST
Measuring range [m] 0.05...1
Sampling rate [Hz] 180
Software / programming
Parameter setting options Distance / reflectivity; hysteresis / window; Sensitivität; current/voltage output; Sequence modulation to avoid mutual interference by similar sensors
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1.3
SDCI standard IEC 61131-9
Profiles Smart Sensor: Sensor Identification; Binary Data Channel; Process Value; Sensor Diagnosis
SIO mode yes
Required master port type A
Min. process cycle time [ms] 5
IO-Link process data (cyclical)
function bit length
process value 2 x 16
device status 4
binary switching information 2
IO-Link functions (acyclical) application specific tag; operating hours counter; switching cycles counter
Supported DeviceIDs
Type of operation DeviceID
default 1581
Note
For further information please see the IODD PDF file under "Downloads"
Operating conditions
Ambient temperature [°C] -25...55
Note on ambient temperature
In ambient temperatures < -10 °C a warm-up time is necessary.
Laser is off.
Storage temperature [°C] -30...80
Protection IP 65; IP 67
Tests / approvals
EMC
EN 60947-5-2
Laser protection class 1
Notes on laser protection
Caution: laser light
laser class: 1
EN / IEC60825-1:2007
EN / IEC60825-1:2014
Complies with 21 CFR 1040 except for deviations pursuant to Laser Notice No. 50, dated June 2007.
MTTF [years] 319
UL approval
Ta -25...60 °C
Enclosure type Type 1
power supply Class 2
File number UL E174191
Mechanical data
Weight [g] 52.06
Housing rectangular with M18 thread
Dimensions [mm] 61.7 x 22.5 x 45.2
Thread designation M18 x 1
Materials housing: PPSU; ABS; PMMA; PBT / PC; EPDM; front pane: PMMA
Lens alignment side lens
Displays / operating elements
Display
switching status 2 x LED, yellow
1 x alphanumeric display, 4-digit
Operating elements
3 pushbutton
Accessories
Items supplied
lock nuts: 2
Remarks
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; coding: A
Diagrams and graphs
a: sensor
b: object
c: background
x: distance sensor/object [mm]
y: min. distance object/background [mm]
Hysteresis graph for distance measurement / operating mode: FINE
1: Background any (6...90 % remission)
2: background white (90 % remission)
Hysteresis graph for distance measurement / operating mode: STD
1: Background any (6...90 % remission)
2: background white (90 % remission)
Hysteresis graph for distance measurement / operating mode: FAST
1: Background any (6...90 % remission)
2: background white (90 % remission)
1: bright
2: dark
A: switch point
B: reset point
x: object brightness ( object reflectivity )
y: min. reflectivity difference to be detected safely
hysteresis curve for object reflectivity
Other data
Parameter Setting range Factory setting
SEL1 Dist / Refl Dist
OU1 Hno, Hnc, Fno, Fnc.OFF Hno
SP1 [mm] 50...2000 1000
SP1 [%] 6...900 10
nSP1 [mm] 50...2000 900
FSP1 [cm] 50...2000 1100
SF1 [mm] 10...500 50
bSP1 [%] 6...900 40
dSP1 [%] 6...900 30
SF1 [%] 1...100 10
dS1 [s] 0…0.1…5 0
dr1 [s] 0…0.1…5 0
SEL2 Dist / Refl Dist
OU2 Hno, Hnc, Fno, Fnc, OFF Hno
SP2 [mm] 50…2000 2000
SP2 [%] 6…900 6
nSP2 [mm] 50…2000 1800
FSP2 [mm] 50…2000 2000
SF2 [mm] 10…500 50
bSP2 [%] 6…900 20
dSP2 [%] 6…900 10
SF2 [%] 1…100 10
dS2 [s] 0…0.01...5 0
dr2 [s] 0…0.01...5 0
dSO [s] 0…0.01...5 0.1
diS On / OFF On
colr rEd; GrEn; r1ou; G1ou; r2ou; G2ou; r-12; G-ou G1ou
P-n PNP,NPN PNP
OPEr (operating mode) FINE,STD, FAST FINE
SEQ auto; S1...S5 auto
The values apply at
Extraneous light on the object < 10 klx
constant ambient conditions 23 °C / 960 hPa
minimum power-on time in minutes 15