• Products
  • Industries
  • IIoT & Solutions
  • Service
  • Company
  1. Products
  2. Sensors
  3. Analytical sensors
  4. Moisture measurement in oil
  5. LDH122

Oil humidity sensor

LDH122

OIL HUMIDITY SENSOR IO-LINK

Oil humidity sensor

LDH122

OIL HUMIDITY SENSOR IO-LINK

  • Monitors the moisture content and temperature of ester and mineral oils
  • continuous measurement enables condition-based changes and maintenance
  • Easy installation thanks to standardised process connection and M12 connector
  • User-friendly communication and parameterisation via IO-Link
  • ce
  • ukca
  • iolink
Product characteristics
Number of inputs and outputs Number of digital outputs: 1
Process connection threaded connection 1/2" NPT
Application
Special feature Gold-plated contacts
Media mineral oils; synthetic esters; biodegradable oils
Cannot be used for See operating instructions, chapter "Intended use".
Medium temperature [°C] -40...120
Pressure rating [bar] 50
Vacuum resistance [mbar] -1000
Electrical data
Operating voltage [V] 18...30 DC
Current consumption [mA] < 50
Protection class III
Reverse polarity protection yes
Power-on delay time [s] 2
Max. current load total [A] 0.065
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 1
Outputs
Total number of outputs 1
Output signal IO-Link
Number of digital outputs 1
Measuring/setting range
Measuring range [% RH] 0...100
Temperature measurement
Measuring range [°C] -40...120
Accuracy / deviations
Accuracy ± 3; ( ± 5 % in the range < 10 %, > 90 %)
Repeatability [% of the final value] ± 0,5
Resolution [%] 0,1; (process value)
Temperature measurement
Accuracy [K] ± 1
Repeatability [K] ± 0,5
Resolution [K] 0.1
Response times
Response time [s] oil: T09 < 30
Temperature measurement
Response time [s] oil: T09 < 30
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
Profiles Identification and Diagnosis (0x4000), Measurement Data Channel (0x800A)
SIO mode no
Required master port type A
Process data analogue 5
Min. process cycle time [ms] 4.5
Supported DeviceIDs
Type of operation DeviceID
default 1249
Operating conditions
Ambient temperature [°C] -40...85
Storage temperature [°C] -40...85
Max. relative air humidity [%] 100
Protection IP 68; IP 69K; (7 days / 3 m water depth / 0.3 bar: IP 68)
Tests / approvals
EMC
DIN EN 61000-6-2
DIN EN 61000-6-4
Shock resistance
DIN EN 60068-2-27 50 g (11 ms)
Vibration resistance
DIN EN 60068-2-6 20 g (10...2000 Hz)
MTTF [years] 284
UL approval
File number UL E364788
Pressure Equipment Directive Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Mechanical data
Weight [g] 117
Materials stainless steel (316L/1.4404); PEI; Sealing: FKM
Materials (wetted parts) stainless steel (316L/1.4404); PA6 GF50; epoxy resin; Sealing: NBR
Process connection threaded connection 1/2" NPT
Remarks
Remarks
accuracy values expressed in percent refer to the measuring span
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12 (EN 61067-2-101); coding: A; Contacts: gold-plated