Service hotline 0120-78-2070
  1. Products
  2. Sensors
  3. Temperature sensors
  4. Compact transmitters for industrial use
  5. TV7105

Temperature sensor with IO-Link

TV7105

TV7-025CLER14-QFRVG/US

Temperature sensor with IO-Link

TV7105

TV7-025CLER14-QFRVG/US

  • High precision across the entire temperature measurement range
  • Particularly good response dynamics and very short power-on delay time
  • Robust stainless steel housing with very high pressure rating
  • Two programmable switching outputs
  • Continuous transmission of process values via IO-Link
  • User-friendly communication and parameterisation via IO-Link
  • ce
  • ukca
  • cul
  • iolink
Product characteristics
Number of inputs and outputs Number of digital outputs: 2
Measuring range [°C] -50...150
Communication interface IO-Link
Process connection threaded connection G 1/4
Installation length EL [mm] 25
Application
Special feature Gold-plated contacts
Measuring element 1 x Pt 1000; (to DIN EN 60751, class A)
Media liquids and gases
Pressure rating [bar] 400
Note on pressure rating
sensor
When mounted in adapters the specifications of the adapter data sheet apply.
Electrical data
Operating voltage [V] 18...32 DC; ("supply class 2" to cULus)
Current consumption [mA] < 50
Protection class III
Reverse polarity protection yes
Power-on delay time [s] 1
Integrated watchdog yes
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2
Outputs
Total number of outputs 2
Output signal switching signal; IO-Link; (configurable)
Electrical design PNP/NPN
Number of digital outputs 2
Output function normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V] 2.5
Permanent current rating of switching output DC [mA] 100
Measuring/setting range
Measuring range [°C] -50...150
Set point SP [°C] -49.8...150
Reset point rP [°C] -50...149.8
In steps of [°C] 0.1
Resolution
Resolution of switching output [K] 0.1
Accuracy / deviations
Switch point accuracy [K] ± 0,3
Temperature drift per 10 K [K] 0.1 **)
Response times
Dynamic response T05 / T09 [s] 1 / 3; (to DIN EN 60751)
Software / programming
Parameter setting options hysteresis / window; normally open / normally closed; switching logic; switch-on/switch-off delay; Damping; Display unit
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
Operating conditions
Ambient temperature [°C] -40...80
Note on ambient temperature
at medium temperature: < 125 °C
-40...50 °C
at medium temperature: < 150 °C
Storage temperature [°C] -40...100
Protection IP 69K
Tests / approvals
EMC
DIN EN 61000-6-2
DIN EN 61000-6-3
Shock resistance
DIN IEC 68-2-27 50 g (11 ms)
Vibration resistance
DIN EN 60068-2-6 20 g (10...2000 Hz)
MTTF [years] 542.6
UL approval
UL Approval no. K019
Mechanical data
Weight [g] 71.5
Materials stainless steel (1.4404 / 316L); FKM
Materials (wetted parts) stainless steel (1.4404 / 316L); O-ring: FKM
Tightening torque [Nm] 35
Process connection threaded connection G 1/4
Probe diameter [mm] 6
Installation length EL [mm] 25
Remarks
Remarks
The values for accuracy apply to flowing water.
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; coding: A; Contacts: gold-plated