You probably do not come from: India. If necessary, change to: United States
  1. Products
  2. Sensors
  3. Encoders
  4. Absolute singleturn encoders
  5. RN7012

Absolute singleturn encoder with solid shaft

RN7012

RMK0013-C24/E

Absolute singleturn encoder with solid shaft

RN7012

RMK0013-C24/E

  • For precise position, speed, angular and linear measurement
  • Direct output of the values via CANopen interface
  • Robust housing for use in harsh industrial environments
  • High shock and vibration resistance
  • Easy wiring and programming
  • ce
  • ukca
Product characteristics
Resolution 8192 steps; 13 bit
Communication interface CAN
Shaft design solid shaft
Shaft diameter [mm] 10
Application
Function principle absolute
Revolution type singleturn
Electrical data
Operating voltage [V] 10...30 DC
Current consumption [mA] 100; ((10 V DC); 60 (24 V DC))
Reverse polarity protection yes
Outputs
Code binary
Measuring/setting range
Resolution 8192 steps; 13 bit
Software / programming
Parameter setting options CAN parameter; scaling; preset; Baud rate; direction of rotation; Node ID
Addressing address selector switch; 0...126
Interfaces
Communication interface CAN
Factory settings
Baud rate: 125 kBit/s
node ID: 32
CAN
Protocol CANopen; DSP - 406 V3.1; DS 301 V4.02; DS 306 V2.0
Factory settings
Baud rate: 125 kBit/s
node ID: 32
Operating conditions
Ambient temperature [°C] -40...85
Max. relative air humidity [%] 98
Protection IP 65; (on the housing: IP 65; on the shaft: IP 64)
Tests / approvals
Shock resistance
100 g (6 ms)
Vibration resistance
10 g (10...1000 Hz)
MTTF [years] 13
Mechanical data
Weight [g] 555
Dimensions [mm] Ø 58 / L = 99
Materials aluminium
Max. revolution, mechanical [U/min] 12000
Shaft design solid shaft
Shaft diameter [mm] 10
Shaft material
steel (1.4104)
Max. shaft load axial (at the shaft end) [N] 40
Max. shaft load radial (at the shaft end) [N] 110
Fixing flange clamping flange
Displays / operating elements
Display
Preoperational Mode LED, green flashing
Operational Mode LED, green
error message LED, red flashing
Electrical connection
terminal strip in the terminal chamber: