You probably do not come from: Israel. If necessary, change to: United States
  1. Products
  2. Sensors
  3. Flow sensors / flow meters
  4. Magnetic-inductive volumetric flow meters
  5. SMF320

Magnetic-inductive flow meter

SMF320

SMG40KGFFRKG/USD

Magnetic-inductive flow meter

SMF320

SMG40KGFFRKG/USD

  • Magnetic-inductive flow meter (SMF series) for the food and beverage industry
  • Measured variables: flow rate, total volume, temperature, conductivity and fluid detection
  • Easy to set up thanks to app-based menu, guided installation and hygienic pushbuttons
  • Reduced cabling by combining supply voltage and output signals via an M12 connection
  • Housing design increases shock and vibration resistance
  • fcm
  • fda
  • ce
  • ukca
  • ec19352004
  • 3a
Product characteristics
Measuring range
5...750 l/min 300...45000 l/h 0.07...10 m/s 0.3...45 m³/h
Nominal diameter DN40 (1 1/2“)
Process connection ifm-specific device flange
Application
Special feature Gold-plated contacts
Application food and beverage industry
Media conductive liquids; water; hydrous media
Note on media
food products such as beer, milk, fruit juices, soft drinks, ketchup, yoghurt, yoghurt toppings, ice cream
conductivity: ≥ 5 µS/cm
Medium temperature [°C] -20...150
Min. bursting pressure
60 bar 6 MPa
Pressure rating
40 bar 4 MPa
Electrical data
Operating voltage [V] 18...32 DC
Current consumption [mA] 250; (24V)
Protection class III
Reverse polarity protection yes
Power-on delay time [s] < 5
Measuring principle magnetic-inductive
Inputs / outputs
Total number of inputs and outputs 2
Inputs
Inputs
OUT2 external totaliser reset
Outputs
Total number of outputs 2
Output signal
OUT1 pulse signal; totaliser switching signal; diagnostic signal; IO-Link
OUT2 analogue signal; pulse signal; totaliser switching signal; diagnostic signal
Electrical design PNP/NPN
Pulse output flow rate meter
Short-circuit protection yes
Type of short-circuit protection pulsed
Overload protection yes
analogue
Number of analogue outputs 1
Analogue current output [mA] 4...20; (skalierbar)
Max. load [Ω] 500
Resolution of analogue output 0.38 µA
Digital
Number of digital outputs 2
Max. voltage drop switching output DC [V] 2
Permanent current rating of switching output DC [mA] 100
Switching frequency DC [Hz] 0...10000
Measuring/setting range
Measuring range
5...750 l/min 300...45000 l/h 0.07...10 m/s 0.3...45 m³/h
Display range
-900...900 l/min -54000...54000 l/h -12...12 m/s -54...54 m³/h
Resolution
0.1 l/min 50 l/h 0.01 m/s 0.05 m³/h
Note on factory setting
0...11,0 m³/h
Analogue start point ASP
0...600 l/min 0...36000 l/h 0...7.95 m/s 0...36 m³/h
Analogue end point AEP
150...750 l/min 9000...45000 l/h 2...9.95 m/s 9...45 m³/h
Low flow cut-off LFC
0...600 l/min 0...36000 l/h 0...7.95 m/s 0...36 m³/h
Pulse length [s] 0.002...2
Pulse value 0.001...99990000 I
Temperature monitoring
Measuring range [°C] -20...150
Display range [°C] -20...150
Resolution [°C] 0.01
Analogue start point [°C] -20...116
Analogue end point [°C] 14...150
conductivity monitoring
Measuring range [µS/cm] 100...100000
Display range [µS/cm] 0...100000
Resolution [µS/cm] 1
Analogue start point [µS/cm] 0...80000
Analogue end point [µS/cm] 20000...100000
Accuracy / deviations
volumetric flow monitoring
Accuracy (in the measuring range)
with optional factory calibration (available from 2025) ± (0,2 % MW + 2 mm/s)
standard ± (0,5 % MW + 1,5 mm/s)
Repeatability 0,1% MW
Temperature monitoring
Accuracy [K] ± 1
Repeatability [K] ± 0,5
conductivity monitoring
Accuracy (in the measuring range)
in the range of 100...20000 µS/cm ±10% MW
in the range of 20000...100000 µS/cm ±20% MW
Repeatability ± 5% MW
Response times
volumetric flow monitoring
Response time [s] < 0.3
Damping process value dAP [s] 0...5
Temperature monitoring
Response time [s] < 3; (flow velocity: ≥ 0,5m/s)
conductivity monitoring
Response time [s] < 2
Software / programming
Diagnostic functions direction of flow detection; liquid detection
Interfaces
Communication interface IO-Link
Transmission type COM3 (230,4 kBaud)
IO-Link revision 1.1.3
SDCI standard IEC 61131-9
Profiles
Function class Designation
0x4000 Identification and Diagnosis
0x001B Measuring and Switching Sensor, floating point, 4 channel
SIO mode yes
Required master port type A
Process data analogue 6
Process data binary 8
Min. process cycle time [ms] 1.9
IO-Link process data (cyclical)
function bit length
totaliser 32
flow 32
temperature 32
conductivity 32
status 4
binary switching information 8
IO-Link functions (acyclical) direction of flow detection; totaliser; Speicher; operating hours counter; internal temperature; simulation function
Operating conditions
Ambient temperature [°C] -20...65
Storage temperature [°C] -25...80
Protection IP 67; IP 69
Tests / approvals
EMC
DIN 61326-1
Shock resistance
DIN IEC 68-2-27 20 g (18ms)
Vibration resistance
DIN IEC 68-2-6 5 g (10...2000Hz)
MTTF [years] 81
Pressure Equipment Directive Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Mechanical data
Weight [g] 4600
Inlet pipe length 5 x DN
Outlet pipe length 2 x DN
Materials housing: stainless steel (316L/1.4404); flange: stainless steel (304/1.4301); electronics fixture: stainless steel (304/1.4301); electronics: stainless steel (316L/1.4404); Display: PPSU; Display-Sealing: FKM; LED ring: PP
Materials (wetted parts) Pipe section: PFA; electrodes: stainless steel (316L/1.4435)
Nominal diameter DN40 (1 1/2“)
Process connection ifm-specific device flange
Surface characteristics Ra/Rz of the wetted parts ≤ 0.4 μm
Displays / operating elements
Factory setting m³/h; °C; μS/cm
Display
process value full graphics TFT display, multi-colour 3,5" 128 x 128 Pixel
display layouts: 4
display rotation: 4 x 90°
operating status LED ring, three-colour
totaliser Display range -999990...999990 m³
totaliser Resolution 0,00001 m³
Display unit l/min; l/h; hl/min; hl/h; m³/min; m³/h; m/s; μS/cm; S/m; ms/cm
Language German; English; Spanish; French; Italian; Japanese; Korean; Portuguese; Chinese
Operating elements
4 capacitive pushbuttons
Remarks
Remarks
MW = measured value
MEW = Final value of the measuring range
pulse and totaliser signal are only available for one of the two outputs
reference conditions : water , 15...35 °C, inlet pipe length: 10 x DN, outlet pipe length: 5 x DN
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; coding: A; Contacts: gold-plated