You probably do not come from: Ireland. If necessary, change to: United States
Service hotline +3531 461 3200
  1. Products
  2. Sensors
  3. Vibration sensors
  4. Diagnostic electronics
  5. VSE100

Diagnostic electronics for vibration sensors

VSE100

DIAGNOSTIC ELECTRONICS

Diagnostic electronics for vibration sensors

VSE100

DIAGNOSTIC ELECTRONICS

  • For the reliable vibration monitoring of machines and equipment
  • Condition-based maintenance thanks to monitoring of unbalance, rolling element bearing or gear state
  • Inputs for the simultaneous detection of up to four vibration sensors
  • Two switching outputs for pre-alarm and main alarm
  • Analogue inputs for monitoring further measurement variables
  • ce
  • ukca
  • cul
Product characteristics
Frequency range [Hz] 0.1...12000
Communication interface Ethernet
Application
Design parameter setting via PC software VES004
Application continuous vibration monitoring
Electrical data
Operating voltage tolerance [%] 20
Operating voltage [V] 24 DC; (when using the IEPE input: 24 V + 20%; IEPE = Integrated Electronics Piezo Electric)
Current consumption [mA] 200; (24 V)
Protection class III
Inputs / outputs
Total number of inputs and outputs 16; (configurable)
Number of inputs and outputs Number of digital inputs: 8; Number of analogue inputs: 2; number of dynamic inputs: 4; Number of digital outputs: 10; Number of analogue outputs: 1
Inputs
Total number of inputs 10
Number of digital inputs 8; (configurable)
Input circuit of digital inputs HTL
Number of analogue inputs 2
Analogue input (current) [mA] 4...20
Resolution of analogue input 12
Number of dynamic inputs 4
Dynamic input - signal 0...10 mA / IEPE / 4...20 mA
Dynamic input - resolution [bit] 16
Dynamic input - frequency range [Hz] 0,1...12000
Dynamic input - sampling rate [kSamples] 100
Outputs
Total number of outputs 10
Output signal switching signal; analogue signal
Electrical design PNP
Number of digital outputs 10; (configurable)
Output function normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V] 2
Permanent current rating of switching output DC [mA] 100
Number of analogue outputs 1; (configurable)
Analogue current output [mA] 0...22; (0...10 V)
Max. load [Ω] 500
Short-circuit protection yes
Type of short-circuit protection pulsed
Overload protection yes
Measuring/setting range
Frequency range [Hz] 0.1...12000
Interfaces
Communication interface Ethernet
Protocol TCP/IP
Operating conditions
Ambient temperature [°C] 0...70
Storage temperature [°C] 0...70
Protection IP 20
Tests / approvals
EMC
EN IEC 61000-6-2
EN IEC 61000-6-4
MTTF [years] 89
UL approval
Ta 70 °C
Enclosure type Type 1
power supply Limited Voltage/Current
Mechanical data
Weight [g] 460.6
Housing plastic housing
Type of mounting rail; (TH35/EN60715)
Dimensions [mm] 114 x 50 x 105
Materials PA
Data memories
History memory yes
Data memory buffered yes
Data memory type ring memory; FIFO
Real-time clock yes
Memory location internal
Memory interval min. 1 min
Memory size 881664 data records
Accessories
Accessories (optional)
cross-over Ethernet patch cable for the direct connection to the PC
Remarks
Pack quantity 1 pcs.
Electrical connection
Connection COMBICON: ; Maximum cable length: 250 m