Application
Application | coding of workpiece carriers in routing conveyors |
---|---|
Operating temperature (active) [°C] | -25...85 |
Peak temperature (passive) [°C] | 200; (duration of test: 160 °C: 500 x 20 min, 200 °C: 10 x 20 min) |
Electrical data
Operating frequency [MHz] | 0,125 |
---|---|
Memory size [bit] | 224 |
Max. read cycles | unlimited |
Max. write cycles | 100000 |
Operating conditions
Ambient temperature [°C] | -25...85 |
---|---|
Storage temperature [°C] | -25...140 |
Protection | IP 68 |
Tests / approvals
Shock resistance |
|
||
---|---|---|---|
Vibration resistance |
|
||
MTTF [years] | 2854 |
Mechanical data
Weight [g] | 4.9 |
---|---|
Dimensions [mm] | Ø 26 / L = 4 |
Materials | PA High Temperature |
Remarks
Remarks |
|
||||||
---|---|---|---|---|---|---|---|
Pack quantity | 1 pcs. |
Other data
read/write distance (mm)
positioning of the ID tag | read | write | ||
DTA100 | overhead | 15...40 | 15...40 | |
DTA101 | overhead | 15...40 | – | |
DTA200 | front side | 55 | 55 | |
DTA201 | front side | 55 | – | |
DTA300 | front side | 80 | 80 | |
DTA301 | front side | 80 | – |
All indications apply to static read/write operations. | |
Indications without comment refer to the installation of ID tags in non-metallic environments. |