Application
Application | coding of workpiece carriers in routing conveyors |
---|---|
Installation | installation on metal |
Operating temperature (active) [°C] | -25...85 |
Peak temperature (passive) [°C] | 160; (duration of test: 1 x 35 h) |
Electrical data
Operating frequency [MHz] | 0,125 |
---|---|
Memory size [bit] | 224 |
Max. read cycles | unlimited |
Max. write cycles | 100000 |
Operating conditions
Ambient temperature [°C] | -25...85 |
---|---|
Storage temperature [°C] | -25...130 |
Protection | IP 67 |
Tests / approvals
Shock resistance |
|
||
---|---|---|---|
Vibration resistance |
|
||
MTTF [years] | 2854 |
Mechanical data
Weight [g] | 9.85 |
---|---|
Housing | threaded type |
Type of mounting | screw mounting |
Dimensions [mm] | M18 x 1 / L = 16.2 |
Thread designation | M18 x 1 |
Materials | threaded sleeve: PBT orange |
Accessories
Items supplied |
|
---|
Remarks
Remarks |
|
||||
---|---|---|---|---|---|
Pack quantity | 1 pcs. |
Other data
read/write distance (mm)
positioning of the ID tag | read | write | ||
DTA100 | overhead | 5...20 / 8* | 5...20 / 8* | |
DTA101 | overhead | 5...20 / 8* | – | |
DTA200 | front side | 25 | 25 | |
DTA201 | front side | 25 | – | |
DTA300 | front side | 40 | 40 | |
DTA301 | front side | 40 | – |
All indications apply to static read/write operations. | |
Indications without comment refer to the installation of ID tags in non-metallic environments. | |
*) | ID tag flush installation in metal |