AL3050

ETH Switch SL IoT 6P IP67

Ethernet switch

AL3050

ETH Switch SL IoT 6P IP67

  • 6-port switch (unmanaged) for all common automation protocols and IIoT applications
  • Voltage supply with standardised A-coded M12 connection technology
  • Robust housing for use in harsh industrial environments
  • Suitable for coolant emulsions, cleaning liquids or heavily polluted water
  • Suitable for mobile machines thanks to high tolerance for operating voltage and operating temperature
  • ce
  • e20
  • ukca
  • cul
Application
Design unmanaged switch for field applications
Application for TCP/IP networks; for EtherNet/IP networks; for Modbus TCP networks
Electrical data
Operating voltage [V] 8...32 DC; ((US ; to SELV/PELV))
Nominal voltage DC [V] 12 / 24
Current consumption [mA] 100; (US; 24 V: 50 mA)
Protection class III
Reverse polarity protection yes
Interfaces
Communication interface Ethernet
Number of Ethernet interfaces 6
Transmission standard 10Base-T; 100Base-TX
Transmission rate 10 MBit/s; 100 MBit/s
Note on interfaces
processing type: Store and Forward
auto polarity
auto negotiation
auto MDI-X
QoS (Quality of Service): IEEE 802.1p, IEEE 802.1Q
priority queues: 4
MAC table size: 2000 addresses
transmission: LLDP, PTCP 01:80:C2:00:00:0E
Operating conditions
Ambient temperature [°C] -25...70
Storage temperature [°C] -25...85
Max. relative air humidity [%] 90
Max. height above sea level [m] 4000
Protection IP 65; IP 66; IP 67
Protection rating (NEMA 250) 6P
Pollution degree 2
Chemical media
ISO 16750-5 AA, BA, BD, HLP, CC, DB, DC, DD, CA
NEMA 250 5.13.1 AA
Tests / approvals
EMC
UN/ECE-R10 noise emission and noise interference: 100 V/m
DIN EN 61000-6-2 ESD
DIN EN 61000-6-4 Burst
ISO 7637-2 pulse 1 severity level 4 / function state C (12 V)
ISO 7637-2 pulse 2a severity level 4 / function state A (12 V)
ISO 7637-2 pulse 2b severity level 4 / function state C (12 V)
ISO 7637-2 pulse 3a severity level 4 / function state A (12 V)
ISO 7637-2 pulse 3b severity level 4 / function state A (12 V)
ISO 7637-2 pulse 4 severity level 4 / function state A (12 V)
ISO 7637-2 pulse 5a severity level 3 / function state A (12 V)
ISO 7637-2 pulse 1 severity level 4 / function state C (24 V)
ISO 7637-2 pulse 2a severity level 4 / function state A (24 V)
ISO 7637-2 pulse 2b severity level 4 / function state C (24 V)
ISO 7637-2 pulse 3a severity level 4 / function state A (24 V)
ISO 7637-2 pulse 3b severity level 4 / function state A (24 V)
ISO 7637-2 pulse 4 severity level 4 / function state A (24 V)
Shock resistance
DIN EN 60068-2-27
Fast temperature change
EN 60068-2-30
EN 60068-2-78
EN 60068-2-52
Vibration resistance
DIN EN 60068-2-64
DIN EN 60068-2-6
EN 60068-2-27
Mechanical data
Weight [g] 301.15
Materials housing: PA orange; socket: brass nickel-plated
Sealing material FKM
Remarks
Remarks
For further information please see the operating instructions.
Pack quantity 1 pcs.
Electrical connection - Ethernet
X01...X06 Connector: 6 x M12; coding: D; Sealing: FKM
Electrical connection - power supply
X31 Connector: 1 x M12; coding: A