Switched-mode power supply 24 V DC

DN4218

PSU-1AC/24VDC-12A/IOL/IP67

Switched-mode power supply 24 V DC

DN4218

PSU-1AC/24VDC-12A/IOL/IP67

  • Output voltage, load currents, output circuit states and trigger cause are communicated via IO-Link
  • Switching the output circuits on and off as well as resetting the circuit breakers is possible via IO-Link
  • ce
  • ukca
  • iolink
  • cul
Data kelistrikan
Tegangan nominal AC [V] 230
Tegangan nominal DC [V] 300
Frekuensi nominal AC [Hz] 50...60
Tegangan input DC [V] 110...300
Rentang tegangan input AC [V] 100...240
Tegangan output DC [V] 24...28
Kelas perlindungan I
Waktu penundaan pengaktifan maks. [ms] 1.3
Arus output maks. pada tegangan output minimal [A] 12.5
Arus output maks. pada tegangan output maksimal [A] 10.7
Daya output (permanen) [W] 300
Daya output (puncak) [W] 600
Faktor daya (tegangan nominal 230 V AC / 50 Hz) 0.97
Jumlah sirkuit output 4
Efisiensi (tegangan nominal 120 V AC / 60 Hz) [%] 94.3
Efisiensi (tegangan nominal 230 V AC / 50 Hz) [%] 95.7
Waktu buffering listrik (tegangan nominal 120 V AC / 60 Hz) [ms] 44
Waktu buffering listrik (tegangan nominal 230 V AC / 50 Hz) [ms] 44
Arus input (tegangan nominal 120 V AC / 60 Hz) [A] 3.2
Arus input (tegangan nominal 230 V AC / 50 Hz) [A] 1.68
Interface
Interface komunikasi IO-Link
Tipe transmisi COM3 (230,4 kBaud)
Revisi O-Link 1.1
Mode SIO ya
Waktu siklus proses min. [ms] 2.2
Kondisi pengoperasian
Suhu sekitar [°C] -25...55
Catatan tentang suhu sekitar
penurunan beban arus yang ditunjukkan pada petunjuk pengoperasian harus diperhitungkan pada suhu lingkungan berikut ini: 70 °C
Suhu penyimpanan [°C] -40...85
Kelembapan udara relatif maks. [%] 95; (kelembapan relatif)
Ketinggian maks. di atas permukaan laut [m] 5000
Perlindungan IP 65; IP 67
Tingkat kekotoran 3
Pengujian/persetujuan
EME
EN 61000-4-2 CD 8 kV / kriteria kegagalan A
EN 61000-4-2 AD 15 kV / kriteria kegagalan A
EN 61000-4-3 80 Mhz...2.7 GHz / 20 V/m kriteria kegagalan A
EN 61000-4-3 2.7 GHz...6 GHz kV / 10 V/m kriteria kegagalan A
EN 61000-4-8 50 / 60 Hz / 30 A/m kriteria kegagalan A
EN 61000-4-4 Burst 4 kV / kriteria kegagalan A
EN 61000-4-5 Surge 2 kV Lx / Ly / kriteria kegagalan A
EN 61000-4-5 Surge 4 kV L / PE / kriteria kegagalan A
EN 61000-4-5 Surge 1 kV + / - / kriteria kegagalan A
EN 61000-4-5 Surge 1 kV + - / PE / kriteria kegagalan A
EN 61000-4-5 Surge 1 kV + - / PE / kriteria kegagalan A
EN 61000-4-5 Surge 1 kV DC-OK / PE / kriteria kegagalan A
EN 61000-4-6 0.15...80 MHz / 20 V kriteria kegagalan A
EN 61000-4-11 0 V hingga 1 siklus / kriteria kegagalan A
EN 61000-4-11 40 % of V / 200 ms kriteria kegagalan A
EN 61000-4-11 70 % of V / 500 ms kriteria kegagalan A
EN 61000-4-11 0 V / 5000 ms kriteria kegagalan C
VDE 0160 1550 V / 1.3 ms kriteria kegagalan A
EN 55032 Class B
EN 55032 Class B
EN 55011 Class B
EN 61000-3-2
EN 61000-3-3
Ketahanan terhadap guncangan yang kontinu
IEC 60068-2-27 30 g 6 ms / 20 g 11 ms
Ketahanan terhadap getaran
IEC 600068-2-6 2...17.8 Hz ± 1.6mm / 17.8...500 Hz 2 g
Data teknis
Berat [g] 1524.5
Dimensi [mm] 182 x 183 x 59
Material casing: alloy aluminium; penutup casing: PC; sekrup: baja dilapisi perunggu
Keterangan
Jumlah paket 1 buah
Koneksi listrik - IO-Link
Konektor: 1 x M12; pengkodean: A; Penguncian: kuningan
Koneksi listrik - Tegangan output
Konektor: 2 x M12; pengkodean: A; Penguncian: kuningan
Koneksi listrik - suplai tegangan
Konektor: 1 x 7/8"; Penguncian: kuningan
Diagram dan grafik
diagram blok
karakteristik output
kurva karakteristik untuk tingkat efisiensi/kehilangan daya
garis karakteristik untuk derating