1. Homepage
  2. Products
  3. Position sensors
  4. Cylinder sensors
  5. Use on T-slot cylinders
  6. MR0100

T-slot cylinder sensor with reed contact

MRT2021BAKOA/R/ZH

MR0100

{{'OPTIONAL_INFO' | productAvailability | error}}

Dear customer,
Unfortunately, this data sheet is not available in the requested language. If you have any further questions, you can contact us by e-mail.

Best regards
Your ifm team

  • Self-locking fixture for quick mounting and easy adjustment
  • Easy fit 'drop from the top' into a slot
  • Moulded cable ensuring very good strain relief
  • With combined AC/DC output and two-wire technology
  • Very high switching frequency
  • ccc
  • ce
  • eac
  • cul
Download
Technische Details
Electrical data
Operating voltage [V] 5...120 AC/DC; (UL supply class 2: 5...60 DC / 5...30 AC)
Protection class II
Reverse polarity protection yes
Outputs
Electrical design PNP/NPN
Output function normally open
Max. voltage drop switching output DC [V] 5
Max. voltage drop switching output AC [V] 5
Permanent current rating of switching output AC [mA] 100; (External protective circuit for inductive load (valve, contactor, etc.) necessary.)
Permanent current rating of switching output DC [mA] 100; (External protective circuit for inductive load (valve, contactor, etc.) necessary.)
Switching frequency AC [Hz] 1000
Switching frequency DC [Hz] 1000
Max. switching power [W] 10
Short-circuit proof no
Overload protection no
Detection zone
Response sensitivity [mT] 2.1
Travel speed [m/s] 10
Accuracy / deviations
Hysteresis [mm] 1
Repeatability [mm] -0.2...0.2
Response times
Max. fall time [ms] 0.1
Max. make time incl. bounce [ms] 0.6
Operating conditions
Ambient temperature [°C] -25...70
Protection IP 65; IP 67
Tests / approvals
EMC
EN 61000-4-2 ESD - CD / 8 kV AD
EN 61000-4-3 HF radiated 10 V/m
EN 61000-4-4 Burst 2 kV
EN 61000-4-5 Surge 2 kV line to line, Ri: 2 Ohm
EN 61000-4-6 HF conducted 10 V
EN 55011 class B
MTTF [years] 11303
UL approval
UL Approval no. C004
Mechanical data
Weight [g] 31.3
Mounting flush mountable
Cylinder type T-slot cylinders
Dimensions [mm] 30.5 x 5 x 6.5
Materials housing: PA; fastening clamp: stainless steel
Switching cycles when connected to PLC [Mio] < 40
Displays / operating elements
Display
switching status 1 x LED, yellow
Electrical connection
Required protection miniature fuse to IEC60127-2 sheet 1; ≤ 0,175 A; fast acting
Accessories
Accessories (supplied)
rubber placeholder: 1
Cable clip: 1
Remarks
Remarks
No LED function in case of polarity reversal in DC operation.
operating voltage "supply class 2" according to UL
Pack quantity 1 pcs.
Electrical connection
Connection Cable: 2 m, PUR; 2 x 0.14 mm²
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — MR0100-01 — 12.06.2015 —