Product characteristics |
Number of inputs and outputs |
Number of digital outputs: 1; Number of analogue outputs: 1 |
Measuring range |
-25...160 °C |
-13...320 °F |
|
Process connection |
diameter Ø 6 mm |
Installation length EL [mm] |
350 |
Application |
Special feature |
Gold-plated contacts |
Measuring element |
1 x Pt 1000 |
Reference element |
1 x NTC |
Media |
liquids and gases |
Pressure rating [bar] |
160 |
Electrical data |
Operating voltage [V] |
18...32 DC; ("supply class 2" to cULus) |
Current consumption [mA] |
10; (24 V) |
Protection class |
III |
Reverse polarity protection |
yes |
Power-on delay time [s] |
6 |
Integrated watchdog |
yes |
Inputs / outputs |
Number of inputs and outputs |
Number of digital outputs: 1; Number of analogue outputs: 1 |
Outputs |
Total number of outputs |
2 |
Output signal |
analogue signal; IO-Link; calibration check status |
Electrical design |
PNP/NPN |
Number of digital outputs |
1 |
Output function |
normally closed; (diagnostic signal) |
Max. voltage drop switching output DC [V] |
2 |
Permanent current rating of switching output DC [mA] |
100 |
Diagnostic output |
calibration check status and error diagnostics |
Number of analogue outputs |
1 |
Analogue current output [mA] |
4...20 |
Max. load [Ω] |
(Ub - 15 V) x 50 |
Short-circuit protection |
yes |
Type of short-circuit protection |
pulsed |
Overload protection |
yes |
Measuring/setting range |
Measuring range |
-25...160 °C |
-13...320 °F |
|
Note on measuring range |
|
Factory setting |
-10...150 °C / 14...302 °F |
Calibration check limit [K] |
0.5...3 |
In steps of [K] |
0.05 |
Resolution |
Resolution of analogue output [K] |
0.05 |
Accuracy / deviations |
Precision analogue output [K] |
± 0,2 |
Precision IO-Link [K] |
± 0,2 |
Temperature coefficient analogue output [% of the span / 10 K] |
< ± 0,02; (in case of deviation from the reference condition 25 ± 5 °C) |
Temperature coefficient IO-Link [% of the span / 10 K] |
< ± 0,01; (in case of deviation from the reference condition 25 ± 5 °C) |
Response times |
Dynamic response T05 / T09 [s] |
1,5 / 4 |
Software / programming |
Parameter setting options |
Display unit; scaling of the analogue output; calibration check limit; switching logic diagnostic output; simulation mode |
Interfaces |
Communication interface |
IO-Link |
Transmission type |
COM2 (38,4 kBaud) |
IO-Link revision |
1.1 |
SDCI standard |
IEC 61131-9 CDV |
Profiles |
Digital Measuring Sensor, Common Profile, Blob Transfer |
SIO mode |
yes |
Required master port type |
A |
Process data analogue |
1 |
Process data binary |
1 |
Min. process cycle time [ms] |
4.4 |
IO-Link resolution temperature [K] |
0.01 |
Supported DeviceIDs |
Type of operation |
DeviceID |
Default |
1129 |
|
Operating conditions |
Ambient temperature [°C] |
-25...70 |
Note on ambient temperature |
max. internal device temperature: 125 °C |
|
Storage temperature [°C] |
-40...100 |
Protection |
IP 68; IP 69K |
Tests / approvals |
EMC |
DIN EN 61000-6-2 |
|
DIN EN 61000-6-3 |
|
|
Shock resistance |
DIN EN 68000-2-27 |
50 g (11 ms) |
|
Vibration resistance |
DIN EN 60068-2-6 |
35 g (10...2000 Hz) |
|
MTTF [years] |
329 |
Note on approval |
factory certificate available as download at www.factory-certificate.ifm |
|
UL approval |
UL Approval no. |
K021 |
File number UL |
E217884 |
|
Mechanical data |
Weight [g] |
315.6 |
Dimensions [mm] |
Ø 50 / L = 393.5 |
Materials |
stainless steel (1.4404 / 316L); PEI; FKM; PFA |
Materials (wetted parts) |
stainless steel (1.4404 / 316L); PEEK |
Process connection |
diameter Ø 6 mm |
Surface characteristics Ra/Rz of the wetted parts |
Ra: < 0.8 |
Probe diameter [mm] |
6 |
Installation length EL [mm] |
350 |
Remarks |
Remarks |
MS = set measuring span |
operating voltage "supply class 2" according to cULus |
|
Pack quantity |
1 pcs. |
Electrical connection |
Connection |
Connector: 1 x M12; Contacts: gold-plated |