1. Homepage
  2. Products
  3. Process sensors
  4. Flow sensors / flow meters
  5. Vortex flow meters
  6. SV3150

SV3150

Vortex flow meter

SVM12XXXD0KG/US-100

{{'OPTIONAL_INFO' | productAvailability | error}}

Dear customer,
Unfortunately, this data sheet is not available in the requested language. If you have any further questions, you can contact us by e-mail.

Best regards
Your ifm team

  • Reliable detection of flow in pipes
  • Precise linearized analogue output
  • Suitable for water and water-based media
  • ce
Download
Technische Details
Product characteristics
Number of inputs and outputs Number of analogue outputs: 1
Measuring range
0.5...10 l/min 0.074...1.474 m/s
Process connection threaded connection G 1/2 DN6
Application
Application for industrial applications
Installation connection to pipe by means of an adapter
Media water; glycol solutions; coolants
Medium temperature [°C] -40...100
Min. bursting pressure [bar] 25
Pressure rating [bar] 12
Note on pressure rating
up to 40 °C
Electrical data
Operating voltage [V] 8...33 DC
Min. insulation resistance [MΩ] 100; (500 V DC)
Protection class III
Power-on delay time [s] < 2
Inputs / outputs
Number of inputs and outputs Number of analogue outputs: 1
Outputs
Total number of outputs 1
Output signal analogue signal
Number of analogue outputs 1
Analogue current output [mA] 4...20; (Q [l/min] = 0,625 x (I - 4 mA))
Max. load [Ω] < (Ub - 8 V) / 20 mA; Ub = 24 V: 800
Measuring/setting range
Measuring range
0.5...10 l/min 0.074...1.474 m/s
Accuracy / deviations
Flow monitoring
Accuracy (in the measuring range) Q < 50 % MEW: < 1 % MEW / Q > 50 % MEW: < 2 % MW; (water)
Repeatability 0,2; (% of the final value)
Response times
Flow monitoring
Response time [s] 0.5
Operating conditions
Ambient temperature [°C] -15...85
Note on ambient temperature
medium temperature > 0 °C: -30...85
Storage temperature [°C] -30...85
Protection IP 65
Cavitation P(absolute) discharge / P(difference) > 5.5 to avoid cavitation
Tests / approvals
EMC
EN 61326-2-3
Shock resistance
DIN EN 60068-2-27 30 g (11 ms)
Vibration resistance
DIN EN 60068-2-6 with water / 10...61 Hz 1 mm
with water / 61...2000 Hz 2 g
MTTF [years] 380
Pressure Equipment Directive Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Mechanical data
Weight [g] 66
Materials PA 6T
Materials (wetted parts) ETFE; PA 6T; EPDM
Tightening torque [Nm] 12
Process connection threaded connection G 1/2 DN6
Remarks
Remarks
MW = measured value
MEW = Final value of the measuring range
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; Contacts: gold-plated
Diagrams and graphs
Pressure loss
dP Pressure loss
Q volumetric flow quantity
min. life 10 years referred to flow and high medium temperatures
pressure rating (bar)