Product characteristics |
Electrical design |
PNP |
Output function |
2 x OSSD (A1 and A2) |
Enable zone [mm] |
> 14.5 |
Housing |
threaded type |
Dimensions [mm] |
M30 x 1.5 / L = 65 |
Application |
Special feature |
Gold-plated contacts |
Type of operation |
permanent operation |
Safety-related function |
safe state when damped correctly |
Application |
Use in mobile and harsh applications |
Electrical data |
Operating voltage [V] |
8...32 DC |
Rated insulation voltage [V] |
60 |
Current consumption [mA] |
< 20 |
Protection class |
III |
Reverse polarity protection |
yes |
Max. power-on delay time [ms] |
1000 |
Outputs |
Electrical design |
PNP |
Output function |
2 x OSSD (A1 and A2) |
Max. voltage drop switching output DC [V] |
2.5; (30 mA) |
Minimum load current [mA] |
1 |
Permanent current rating of switching output DC [mA] |
50 |
Switching frequency DC [Hz] |
10 |
Output data |
Interface type C class 1 |
Output voltage at 24 V |
compatible with EN 61131-2 inputs type 1, 2 |
Short-circuit protection |
yes |
Overload protection |
yes |
Max. capacitive load CL_max [nF] |
20 |
Detection zone |
Enable zone [mm] |
> 14.5 |
Safe switch-off distance s(ao) [mm] |
< 8 |
Accuracy / deviations |
Correction factor |
steel: 1 / stainless steel: 0.7 / brass: 0.5 / aluminium: 0.4 / copper: 0.4 |
Hysteresis [% of Sr] |
1...10 |
Response times |
Response time to safety request [ms] |
5 |
Response time when approaching the enable zone [ms] |
5 |
Risk time (response time for safety-related faults) [ms] |
100 |
Operating conditions |
Ambient temperature [°C] |
-40...85 |
Max. relative air humidity [%] |
50; (70 °C; <70 °C: >50 %) |
Max. height above sea level [m] |
5000 |
Ionising radiation |
not permissible |
Protection |
IP 65; IP 67; IP 68; IP 69K; (with ifm socket duly screwed on) |
Chemical media |
test according to ISO 16750-5 |
|
|
|
the following media were tested for 22 hours at 60 °C |
coolants |
|
(HoughtonHocut4480 |
|
Oemeta |
|
HYCUT ET 46) |
The following media were tested for 22 hours at 75 °C |
hydraulic fluids |
|
(Fuchs Renoling B15 VG 46 HLP |
|
Total BiohydranTMP 4HEES |
|
Fuchs Hydrotherm 46 M HFC) |
|
transmission oils |
|
(Fuchs TITAN ATF 3353 Dexron III) |
|
diesel |
|
biodiesel |
|
urea |
|
(AdBlue) |
|
brake fluid |
|
(K2 TURBO DOT 4) |
the following media were tested for 22 hours at 23 °C |
corrosion protection |
|
(Sonax special preservation wax ) |
|
cold cleaner |
|
(Sonax cold cleaner S ) |
|
ammonia-based cleaner |
|
(Weco Dr. Webers Salmiak-Konzentrat (concentrated ammonium chloride) ) |
|
battery acid |
the following media were tested for 2 hours at 23 °C |
wheel rim cleaner |
|
(Sonax Xtreme Plus) |
the following media were tested for 10 minutes at 23 °C |
premium-grade petrol lead-free |
|
|
|
|
|
|
|
Tests / approvals |
EMC |
industrial environments |
|
EN 60947-5-3 |
|
EN 61000-4-2 ESD |
6 kV CD / 8 kV AD |
EN 61000-4-3 HF radiated |
20 V/m |
EN 61000-4-4 Burst |
2 kV |
EN 61000-4-5 Surge |
2 kV |
EN 61000-4-6 HF conducted |
10 V |
EN 61000-4-8 |
30 A/m 50/60 Hz / 1000 A/m 0 Hz |
EN 55011 |
class B |
mobile applications |
only for operation with central load-dump suppression (58 V) / not for active operation during motor start phase in 12 V systems |
ISO 10605 ESD |
8 kV CD / 15 kV AD |
ISO 11452-2, ISO 11452-5 radiated immunity |
100 V/m |
ISO 7637-2, ISO 16750-2 conducted immunity |
12 V / 24 V |
pulse |
1 2a 3a 3b 4 5b |
severity level |
III III III III III III 58V |
failure criterion |
B B B A A C/B A |
EN 55025 |
|
|
Vibration resistance |
EN 60068-2-6 Fc |
20 g (10...3000 Hz) / 50 sweep cycles, 1 octave per minute, in 3 axes |
|
Broadband noise |
EN 60068-2-64 h |
5,9 g (10...2000 Hz) / effective acceleration for chassis mounting |
|
Shock resistance |
EN 60068-2-27 Ea |
100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes |
|
Continuous shock resistance |
EN 60068-2-27 Ea |
40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes |
|
Fast temperature change |
EN 60068-2-14 Na |
TA = -40°C; TB = 85°C; t1 = 30 min; t2 = 10 s 100 cycles |
|
Salt spray test |
EN 60068-2-52 Kb |
severity level 5 (4 test cycles) |
|
UL approval |
Ta |
< 70 °C |
Enclosure type |
Type 1 |
voltage supply |
Limited Voltage/Current |
File number UL |
E174191 |
|
Safety classification |
Complies with the requirements |
ISO 13849-1: 2015 category 2, PL d |
IEC 61508 SIL 2 |
IEC 62061 SIL 2 |
|
Mission time TM [h] |
≤ 87600 |
Mission time TM (additional indication) |
industrial environments Temperature range -25...70 °C ≤ 175200 |
|
PFH [1/h] |
< 5E-08 |
Mechanical data |
Weight [g] |
196.8 |
Housing |
threaded type |
Mounting |
flush mountable |
Dimensions [mm] |
M30 x 1.5 / L = 65 |
Thread designation |
M30 x 1.5 |
Materials |
threaded sleeve: brass white bronze coated; sensing face: LCP; LED window: PEI; lock nuts: brass white bronze coated |
Tightening torque [Nm] |
< 50 |
Displays / operating elements |
Display |
Display switching status |
4 LED, yellow |
|
Accessories |
Items supplied |
|
Remarks |
Remarks |
material for secure mounting not supplied; fixing must be done by the user |
meets the environmental and EMC requirements for operation in agricultural and forestry machinery, earthworks and construction machines as well as in industrial trucks |
Unless stated otherwise, all data refer to the reference target plate to IEC 60947-5-2 over the whole temperature range. |
(FE360 = ST37-2K) 30x30x1 mm |
|
Pack quantity |
1 pcs. |
Electrical connection - plug |
Connection |
Connector: 1 x M12; coding: A; Contacts: gold-plated |