Factory certificate – for selected sensors (test on the basis of IEC 60770)

  • Service free of charge from the ifm group of companies
  • 3-point factory certificate available as PDF document, also after the unit has been ordered
  • Languages: in two languages English/German
  • For selected products:
    Available for the following product series: PI27xx, PI28xx, PM1xxx, TA20xx, TA22xx, TA25xx, TA28xx, TD22xx, TD25xx, TD28xx,
    TD29xx (manufactured as of 01/2018)
  • PG27xx, PG28xx (manufactured as of 01/2019)

Manufacturer's certificate EN10204-2.1 (order code ZC0001)
(according to DIN50049-2.1)

  • Certifies that the listed articles / article groups conform to the indications in the corresponding data sheet and have been subjected to a 100 % final test.
  • The document is bilingual (German / English).

Manufacturer's certificate EN10204-2.2 (order code ZC0002)
(according to DIN 50049-2.2)

  • Certifies that the listed articles / article groups conform to the indications in the corresponding data sheet and have been subjected to a 100 % final test.
  • Annexes: description of the 100 % tests
  • The document is bilingual (German / English).

The following documents are available for selected fluid sensor products:

Inspection certificate material EN10204-3.1 (order code ZC0003)
(according to DIN 50049-3.1)

  • Results of batch-related tests to prove that the requirements regarding the material characteristics and quality are met.
  • The document is bilingual (German / English).
  • Applies to the specified article(s) and must be requested when ordering the article.

ISO calibration protocol pressure (order code ZC0004)

  • Calibration certificate
  • 6 calibration points in steps of 20 % of the measuring range. Other calibration points possible on request.
  • The calibration is carried out in factory setting using the analogue output (current). Alternatively visually via display or analogue output (voltage).
  • Recalibrations are only possible if subjected unit is returned. The unit shall be in a clean state, without adaptations (condition as supplied to the customer). The declaration of decontamination has to be included.
  • The document is bilingual (German / English).
  • Applies to the specified article(s) and must be requested when ordering the article.
  • Subsequent orders are only possible if subjected unit is returned.

DAkkS calibration protocol pressure sensors (order code ZC0005)

  • DKD/DAkkS certificate (DAkkS = Deutsche Akkreditierungsstelle)
  • 11 calibration points. Further calibration points possible on request.
  • The calibration is carried out in factory setting using the analogue output (current). Alternatively visually via display or analogue output (voltage).
  • Recalibrations are only possible if subjected unit is returned. The unit shall be in a clean state, without adaptations (condition as supplied to the customer). The declaration of decontamination has to be included.
  • The document is bilingual (German / English).
  • Applies to the specified article(s) and must be requested when ordering the article.
  • Subsequent orders are only possible if subjected unit is returned.

DAkkS calibration temperature sensors 3-point (order code ZC0013)

  • DKD/DAkkS certificate (DAkkS = Deutsche Akkreditierungsstelle)
  • Comparative calibration in a bath containing the continuously stirred liquid
  • 3 calibration points (65-85-123°C)
  • The calibration is carried out in factory setting using the analogue output (current). Alternatively visually via display or analogue output (voltage).
  • Recalibrations are only possible if subjected unit is returned. The unit shall be in a clean state, without adaptations (condition as supplied to the customer). The declaration of decontamination has to be included.
  • The document is bilingual (German / English).
  • Applies to the specified article(s) and must be requested when ordering the article.
  • Subsequent orders are only possible if subjected unit is returned.

DAkkS calibration temperature sensors 5-point (order code ZC0014)

  • DKD/DAkkS certificate (DAkkS = Deutsche Akkreditierungsstelle)
  • Comparative calibration in a bath containing the continuously stirred liquid
  • 5 calibration points (20-65-85-100-123°C)
  • The calibration is carried out in factory setting using the analogue output (current). Alternatively visually via display or analogue output (voltage).
  • Recalibrations are only possible if subjected unit is returned. The unit shall be in a clean state, without adaptations (condition as supplied to the customer). The declaration of decontamination has to be included.
  • The document is bilingual (German / English).
  • Applies to the specified article(s) and must be requested when ordering the article.
  • Subsequent orders are only possible if subjected unit is returned.

DAkkS calibration temperature sensors N-point (order code ZC0015)

  • DKD/DAkkS certificate (DAkkS = Deutsche Akkreditierungsstelle)
  • Comparative calibration in a bath containing the continuously stirred liquid
  • Number (max. 4) and position of the calibration points according to the customer request (temperature range: -20°C...150°C)
  • The calibration is carried out in factory setting using the analogue output (current). Alternatively visually via display or analogue output (voltage).
  • Recalibrations are only possible if subjected unit is returned. The unit shall be in a clean state, without adaptations (condition as supplied to the customer). The declaration of decontamination has to be included.
  • The document is bilingual (German / English).
  • Applies to the specified article(s) and must be requested when ordering the article.
  • Subsequent orders are only possible if subjected unit is returned.

ISO calibration temperature sensors 3-point (oder code ZC0016)

  • Calibration certificate
  • Comparative calibration in a bath containing the continuously stirred liquid
  • 3 calibration points (65-85-123°C)
  • The calibration is carried out in factory setting using the analogue output (current). Alternatively visually via display or analogue output (voltage).
  • Recalibrations are only possible if subjected unit is returned. The unit shall be in a clean state, without adaptations (condition as supplied to the customer). The declaration of decontamination has to be included.
  • The document is bilingual (German / English).
  • Applies to the specified article(s) and must be requested when ordering the article.
  • Subsequent orders are only possible if subjected unit is returned.

ISO-Kalibrierung Temperatursensoren 5-Punkt (Bestellcode ZC0017)

  • Calibration certificate
  • Comparative calibration in a bath containing the continuously stirred liquid
  • 5 calibration points (20-65-85-100-123°C)
  • The calibration is carried out in factory setting using the analogue output (current). Alternatively visually via display or analogue output (voltage).
  • Recalibrations are only possible if subjected unit is returned. The unit shall be in a clean state, without adaptations (condition as supplied to the customer). The declaration of decontamination has to be included.
  • The document is bilingual (German / English).
  • Applies to the specified article(s) and must be requested when ordering the article.
  • Subsequent orders are only possible if subjected unit is returned.

ISO calibration temperature sensors N-point (order code ZC0018)

  • Calibration certificate
  • Comparative calibration in a bath containing the continuously stirred liquid
  • Number (max. 4) and position of the calibration points according to the customer request (temperature range: -20°C...150°C)
  • The calibration is carried out in factory setting using the analogue output (current). Alternatively visually via display or analogue output (voltage).
  • Recalibrations are only possible if subjected unit is returned. The unit shall be in a clean state, without adaptations (condition as supplied to the customer). The declaration of decontamination has to be included.
  • The document is bilingual (German / English).
  • Applies to the specified article(s) and must be requested when ordering the article.
  • Subsequent orders are only possible if subjected unit is returned.

Cleaning for oxygen applications​ (order code ZC0019)

  • Cleaning for oxygen applications (free of oil and grease).
  • The cleaned units are given a special marking and packaging.
  • Applies to the specified article(s) and must be requested when ordering the article.
  • For each unit ZC0019 has to be ordered separately.

ISO calibration protocol SD (order code ZC0020)

  • Calibration certificate
  • Comparative calibration with standard reference
  • Calibration at 6 flow values (depending on the nominal diameter)
  • The calibration is carried out in factory setting using the analogue output (current). Alternatively visually via display or analogue output (voltage).
  • Recalibrations are only possible if subjected unit is returned. The unit shall be in a clean state, without adaptations (condition as supplied to the customer). The declaration of decontamination has to be included.
  • The document is bilingual (German / English).
  • Applies to the specified article(s) and must be requested when ordering the article.
  • Subsequent orders are only possible if subjected unit is returned.

ISO calibration SM (order code ZC0052)

  • Calibration certificate
  • Comparative calibration with standard reference
  • Calibration at 3 flow values (depending on the nominal diameter)
  • The calibration is carried out in factory setting.
  • Recalibrations are only possible if subjected unit is returned. The unit shall be in a clean state, without adaptations (condition as supplied to the customer). The declaration of decontamination has to be included.
  • The document is bilingual (German / English).
  • Applies to the specified article(s) and must be requested when ordering the article.
  • Subsequent orders are only possible if subjected unit is returned.

ISO calibration SU (order code ZC0053)

  • Calibration certificate
  • Comparative calibration with standard reference
  • Calibration at 4 flow values (depending on the nominal diameter)
  • The calibration is carried out in factory setting.
  • Recalibrations are only possible if subjected unit is returned. The unit shall be in a clean state, without adaptations (condition as supplied to the customer). The declaration of decontamination has to be included.
  • The document is bilingual (German / English).
  • Applies to the specified article(s) and must be requested when ordering the article.
  • Subsequent orders are only possible if subjected unit is returned.

Factory calibration for infra-red temperature sensors (order code ZC0061)

  • Calibration certificate
  • Created according to the requirements of DIN EN ISO 9001:2008
  • The document is bilingual (German / English).
  • Applies to the specified article(s) and must be requested when ordering the article.
  • Subsequent orders are only possible when giving the serial number. The certificate will then be dated with the day of calibration.

Recalibration for infra-red temperature sensor TW20xx (order code ZC0062)

  • Calibration certificate
  • Created according to the requirements of DIN EN ISO 9001:2008
  • Recalibrations are only possible if subjected unit is returned. The unit shall be in a clean state, without adaptations (condition as supplied to the customer). The declaration of decontamination has to be included.
  • The document is bilingual (German / English).
  • Applies to the specified article(s).

Recalibration for infra-red temperature sensor TW2002 (order code ZC0063)

  • Calibration certificate
  • Created according to the requirements of DIN EN ISO 9001:2008
  • Recalibrations are only possible if subjected unit is returned. The unit shall be in a clean state, without adaptations (condition as supplied to the customer). The declaration of decontamination has to be included.
  • The document is bilingual (German / English).
  • Applies to the specified article(s).

A2LA calibration temperature sensors 3-point​ (order code ZC0064)

  • Calibration certificate
  • Created according to A2LA / ILAC MRA
  • Comparative calibration in a bath containing the continuously stirred liquid
  • 3 calibration points (65-85-123°C)
  • The calibration is carried out in factory setting using the analogue output (current). Alternatively visually via display or analogue output (voltage).
  • Recalibrations are only possible if subjected unit is returned. The unit shall be in a clean state, without adaptations (condition as supplied to the customer). The declaration of decontamination has to be included.
  • The document is bilingual (German / English).
  • Applies to the specified article(s) and must be requested when ordering the article.
  • Subsequent orders are only possible if subjected unit is returned.

A2LA calibration temperature sensors 5-point  (order code ZC0065) 

  • Calibration certificate
  • Created according to A2LA / ILAC MRA
  • Comparative calibration in a bath containing the continuously stirred liquid
  • 5 calibration points (20-65-85-100-123°C)
  • The calibration is carried out in factory setting using the analogue output (current). Alternatively visually via display or analogue output (voltage).
  • Recalibrations are only possible if subjected unit is returned. The unit shall be in a clean state, without adaptations (condition as supplied to the customer). The declaration of decontamination has to be included.
  • The document is bilingual (German / English).
  • Applies to the specified article(s) and must be requested when ordering the article.
  • Subsequent orders are only possible if subjected unit is returned.

A2LA calibration temperature sensors N-point​ (order code ZC0066)

  • Calibration certificate
  • Created according to A2LA / ILAC MRA
  • Comparative calibration in a bath containing the continuously stirred liquid
  • Number (max. 4) and position of the calibration points according to the customer request (temperature range: -20°C...200°C)
  • The calibration is carried out in factory setting using the analogue output (current). Alternatively visually via display or analogue output (voltage).
  • Recalibrations are only possible if subjected unit is returned. The unit shall be in a clean state, without adaptations (condition as supplied to the customer). The declaration of decontamination has to be included.
  • The document is bilingual (German / English).
  • Applies to the specified article(s) and must be requested when ordering the article.
  • Subsequent orders are only possible if subjected unit is returned.

Recalibration for oil particle counter LDP (order code ZC0069)

  • Calibration certificate
  • Created according to the requirements of DIN EN ISO 9001:2008
  • Recalibrations are only possible if subjected unit is returned. The unit shall be in a clean state, without adaptations (condition as supplied to the customer). The declaration of decontamination has to be included.
  • The document is bilingual (German / English).
  • Applies to the specified article(s).

DAkkS calibration flow sensors 6-point (order code ZC0075)

  • DKD/DAkkS certificate (DAkkS = Deutsche Akkreditierungsstelle)
  • Comparative calibration with standard reference
  • Calibration at 6 flow values (depending on the nominal diameter)
  • The calibration is carried out in factory setting using the analogue output (current). Alternatively visually via display or analogue output (voltage).
  • Recalibrations are only possible if subjected unit is returned. The unit shall be in a clean state, without adaptations (condition as supplied to the customer). The declaration of decontamination has to be included.
  • The document is bilingual (German / English).
  • Applies to the specified article(s) and must be requested when ordering the article.
  • Subsequent orders are only possible if subjected unit is returned.

INMETRO calibration protocol temperature sensors (order code ZBR001)

  • Calibration certificate
  • Created according to INMETRO regulations
  • The document is available in Portuguese.  
  • Applies to the specified article(s) and must be requested when ordering the article.
  • Subsequent orders are only possible if subjected unit is returned.

INMETRO calibration protocol flow sensors (order code ZBR002)

  • Calibration certificate
  • Created according to INMETRO regulations
  • The document is available in Portuguese. 
  • Applies to the specified article(s) and must be requested when ordering the article.
  • Subsequent orders are only possible if subjected unit is returned.

INMETRO calibration protocol pressure sensors  (order code ZBR003)

  • Calibration certificate
  • Created according to INMETRO regulations
  • The document is available in Portuguese. 
  • Applies to the specified article(s) and must be requested when ordering the article.
  • Subsequent orders are only possible if subjected unit is returned.