You probably do not come from: United Kingdom. If necessary, change to: United States
Service hotline 0208 213 2222
  1. Products
  2. Sensors
  3. Vibration sensors
  4. Diagnostic electronics
  5. VSE903

Diagnostic electronics for vibration sensors

VSE903

DIAGNOSTIC ELECTRONICS

Diagnostic electronics for vibration sensors

VSE903

DIAGNOSTIC ELECTRONICS

  • Robust IP 67 housing for decentralised use
  • Fast, error-free installation and retrofitting thanks to standard M12 connections
  • Six signal inputs collect all relevant data for condition monitoring
  • Compatible with all common acceleration sensors
  • ce
  • ukca
  • cul
Product characteristics
Frequency range [Hz] 0.1...12000
Communication interface Ethernet
Application
Design parameter setting via PC software VES004
Application continuous vibration monitoring
Electrical data
Operating voltage tolerance [%] 20
Operating voltage [V] 24 DC; (when using the IEPE input 24 V + 20% IEPE = Integrated Electronics Piezo Electric)
Current consumption [mA] 200; ((24 V DC))
Protection class III
Inputs / outputs
Total number of inputs and outputs 8; (configurable)
Number of inputs and outputs number of dynamic inputs: 4; Number of digital outputs: 2; Number of analogue outputs: 1
Inputs
Total number of inputs 6
Analogue input (current) [mA] 4...20
Resolution of analogue input 12
Number of dynamic inputs 4
Dynamic input - signal 0...10 mA / IEPE / 4...20 mA
Dynamic input - frequency range [Hz] 0,1...12000
Dynamic input - sampling rate [kSamples] 100
Outputs
Total number of outputs 2
Output signal switching signal; analogue signal
Electrical design PNP
Number of digital outputs 2
Output function normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V] 2
Permanent current rating of switching output DC [mA] 100
Number of analogue outputs 1; (configurable)
Analogue current output [mA] 4...20
Max. load [Ω] 500
Short-circuit protection yes
Type of short-circuit protection pulsed
Overload protection yes
Measuring/setting range
Frequency range [Hz] 0.1...12000
Interfaces
Communication interface Ethernet
Protocol TCP/IP
Note on protocol
10 Mbaud
100 Mbaud
Operating conditions
Ambient temperature [°C] 0...70
Storage temperature [°C] 0...70
Max. relative air humidity [%] 90
Protection IP 67
Tests / approvals
EMC
EN IEC 61000-6-2
EN IEC 61000-6-4
MTTF [years] 92
UL approval
Ta 70 °C
Enclosure type Type 1
power supply Limited Voltage/Current (Marking Class 2)
UL Approval no. L004
File number UL E251902
Mechanical data
Weight [g] 1296.7
Housing aluminium
Type of mounting backplane mounting
Dimensions [mm] 175 x 172 x 66.6
Materials EN AW-5083: black anodised
Data memories
History memory yes
Data memory buffered yes
Data memory type ring memory; FIFO
Real-time clock yes
Memory location internal
Memory interval min. 1 min
Memory size 881664 data records
Accessories
Accessories (optional)
cross-over Ethernet patch cable for the direct connection to the PC
Remarks
Pack quantity 1 pcs.