You probably do not come from: United Kingdom. If necessary, change to: United States
Service hotline 0208 213 2222
  1. Products
  2. Industrial communication
  3. AS-Interface I/O modules
  4. Field modules with quick mounting technology ClassicLine
  5. AC5225

AS-Interface ClassicLine module with quick mounting technology

AC5225

ClassicLine IO-Link 2 Ports

AS-Interface ClassicLine module with quick mounting technology

AC5225

ClassicLine IO-Link 2 Ports

  • Easy toolless installation and wiring thanks to quick mounting technology
  • Three freely selectable directions of the flat cable
  • Clearly visible powerful LEDs for displaying operation, switching status and error
  • High protection rating for the requirements of harsh industrial environments
  • Robust M12 connectors for connecting sensors and actuators
  • ce
  • ukca
  • asib
  • cul
Application
Design only for operation with AS-i masters with the profile M4
Application field installation
Electrical data
Operating voltage [V] 26.5...31.6 DC
Max. current consumption from AS-i [mA] 300
Reverse polarity protection yes
Additional voltage supply [V] 20...30 DC
Inputs
Sensor supply of the inputs AS-i
Digital inputs protected against short circuits yes
Interfaces
Communication interface IO-Link; AS-i
IO-Link Device
Min. process cycle time [ms] 2.3
IO-Link Master
Transmission type COM1 (4,8 kBaud); COM2 (38,4 kBaud)
IO-Link revision 1.0
Number of ports class A 2
Operating conditions
Ambient temperature [°C] -25...70
Protection IP 67
Tests / approvals
EMC
EN 50295
MTTF [years] 149
AS-i classification
AS-i version 3.0
AS-i addressing addressing socket
Extended addressing mode no
AS-i master profile M4
AS-i profile S-7.5.5
AS-i I/O configuration [hex] 7
AS-i ID code [hex] 5.5
Mechanical data
Weight [g] 161.35
Materials PA; piercing contacts: CuSn6 nickel-plated and tin-plated
Displays / operating elements
Display
operation PWR LED, green Voltage AS-i
errors LED, red
switching status LED, yellow DI/DO Port 1, Port 2
communication LED, green IO-Link Port 1, Port 2
disturbed communication LED, red Port 1, Port 2
Electrical connection
Module connection Flat cables
Accessories
Items supplied
lower part
Accessories (optional)
Protective cap: M12, E73004
Remarks
Remarks
When the sensors and actuators are supplied from AS-i the load must not exceed a maximum of 200 mA.
There is an electrical connection between the sensor and AS-i.
operating voltage "supply class 2" according to cULus
Pack quantity 1 pcs.
Electrical connection
quick mounting technology for AS-i flat cable: ; three orientations possible
Connector: M12; coding: A