Product characteristics |
Probe length L [mm] |
42 |
Process connection |
Clamp DN25 ISO 2852 |
Application |
Application |
high-temperature range; hygienic applications |
Pressure rating [bar] |
30 |
Liquids |
Application |
high-temperature range; hygienic applications |
Medium temperature [°C] |
0...120 |
Gases |
Medium temperature [°C] |
0...100 |
Electrical data |
Connection to control monitor |
VS3000 |
Measuring/setting range |
Probe length L [mm] |
42 |
Liquids |
Setting range [cm/s] |
3...300 |
Greatest sensitivity [cm/s] |
3...60 |
Gases |
Setting range [cm/s] |
200...2000 |
Greatest sensitivity [cm/s] |
200...800 |
Accuracy / deviations |
Temperature gradient [K/min] |
15 |
Response times |
Response time [s] |
1...10 |
Liquids |
Response time [s] |
1...10 |
Gases |
Response time [s] |
1...10 |
Operating conditions |
Protection |
IP 67 |
Tests / approvals |
Shock resistance |
DIN IEC 68-2-27 |
40 g (11 ms) |
|
Vibration resistance |
DIN IEC 68-2-6 |
10 g (55...2000 Hz) |
|
MTTF [years] |
8648 |
Mechanical data |
Weight [g] |
485 |
Materials |
stainless steel (1.4571/316Ti ) |
Materials (wetted parts) |
stainless steel (1.4571/316Ti ) |
Process connection |
Clamp DN25 ISO 2852 |
Remarks |
Remarks |
The 3-A qualification is only valid if adapters with 3-A qualification are used for installation. |
|
Pack quantity |
1 pcs. |
Electrical connection |
Connection |
Cable: 6 m, silicone; Maximum cable length: 100 m; 5 x 0.34 mm² |