Product characteristics |
Number of inputs and outputs |
Number of analogue outputs: 1 |
Measuring range |
0...1 bar |
0...1000 mbar |
0...14.5 psi |
0...100 kPa |
|
Application |
Application |
for industrial applications |
Media |
Liquids |
Medium temperature [°C] |
-10...60; (T6: -10...60 °C; T5: -10...80 °C; T4: -10...85 °C; 1 D, 1/2 D, 2 D (750 mW): -10...40 °C; (650 mW): -10...70 °C; (550 mW): -10...85 °C) |
Min. bursting pressure |
|
Pressure rating |
|
Type of pressure |
relative pressure |
Electrical data |
Switching amplifiers |
connection to intrinsically safe supply isolators (Ex ia) |
Operating voltage [V] |
10...30 DC |
Protection class |
III |
Reverse polarity protection |
yes |
Measuring principle |
hydrostatic |
Inputs / outputs |
Number of inputs and outputs |
Number of analogue outputs: 1 |
Outputs |
Total number of outputs |
1 |
Output signal |
analogue signal |
Number of analogue outputs |
1 |
Analogue current output [mA] |
4...20 |
Max. load [Ω] |
700; (Ub = 24 V; (Ub - 10 V) / 20 mA) |
Short-circuit protection |
yes |
Measuring/setting range |
Measuring range |
0...1 bar |
0...1000 mbar |
0...14.5 psi |
0...100 kPa |
|
Accuracy / deviations |
Repeatability [% of the span] |
< 0,1; (with temperature fluctuations < 10 K) |
Characteristics deviation [% of the span] |
< 0,25 (BFSL) / 0,5; (incl. linearity, zero and span error (limit value setting); BFSL = Best Fit Straight Line) |
Linearity deviation [% of the span] |
< 0,2 (BFSL) |
Long-term stability [% of the span] |
< 0,2; (per year) |
Temperature coefficient zero point [% of the span / 10 K] |
< ± 0,2; (0...50 °C) |
Temperature coefficient span [% of the span / 10 K] |
< ± 0,2; (0...50 °C) |
Operating conditions |
Ambient temperature [°C] |
-10...60 |
Note on ambient temperature |
T6: -10...60 °C |
T5: -10...80 °C |
T4: -10...85 °C |
1 D, 1/2 D, 2 D (750 mW): -10...40 °C |
1 D, 1/2 D, 2 D (650 mW): -10...70 °C |
1 D, 1/2 D, 2 D (550 mW): -10...85 °C |
|
Storage temperature [°C] |
-10...60 |
Protection |
IP 68 |
Tests / approvals |
Approval |
BVS 10 ATEX E 132 X; IECEx BVS 10.0085 X |
ATEX marking |
I M1 Ex ia I Ma |
|
II 1 G Ex ia IIA T4/T5/T6 Ga |
|
II 1/2G Ex ia IIC T4/T5/T6 Ga/Gb |
|
II 2 G Ex ia IIC T4/T5/T6 Gb |
|
II 1D Ex ia IIIC T120°C Da |
MTTF [years] |
969 |
Pressure Equipment Directive |
Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Mechanical data |
Weight [g] |
1431.8 |
Materials |
stainless steel (1.4571/316Ti ) |
anzeigen-bedienelemente |
Remarks |
Pack quantity |
1 pcs. |
Electrical connection |
Connection |
Cable: 15 m, FEP, Ø 7.5 mm |