You probably do not come from: Germany. If necessary, change to: United States
ifm-Service-Center 0800 16 16 16 4
  1. Products
  2. Sensors
  3. Photoelectric sensors
  4. Distance sensors type O1D
  5. O1D106

Photoelectric distance sensor

O1D106

O1DLF3KG

Photoelectric distance sensor

O1D106

O1DLF3KG

  • Reliable optical distance measurement
  • Range up to 75 m for use on cranes
  • Two switching outputs, one of them programmable as analogue output
  • Excellent price/performance ratio
  • Wide range of components for quick mounting and precise fine adjustment
  • ce
  • ukca
  • cul
  • iolink
Product characteristics
Laser protection class 2
Housing rectangular
Electrical data
Operating voltage [V] 18...30 DC
Current consumption [mA] < 150
Protection class III
Reverse polarity protection yes
Typ. lifetime [h] 50000
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Outputs
Total number of outputs 2
Electrical design PNP
Number of digital outputs 2
Output function normally open / normally closed; (programmable)
Max. current load per output [mA] 200
Number of analogue outputs 1
Analogue current output [mA] 4...20; (scalable IEC 61131-2)
Max. load [Ω] 250
Analogue voltage output [V] 0...10; (scalable IEC 61131-2)
Min. load resistance [Ω] 5000
Short-circuit protection yes
Type of short-circuit protection pulsed
Overload protection yes
Detection zone
Max. light spot width [mm] 150
Max. light spot height [mm] 150
Light spot dimensions refer to 75 m
Background suppression [m] 75...150
Measuring/setting range
Measuring range [m] 1...75; (Reflector E21159)
Sampling rate [Hz] 1...33
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
Profiles Smart Sensor: Sensor Identification; Binary Data Channel; Process Value; Sensor Diagnosis
SIO mode yes
Required master port type A
Process data analogue 1
Process data binary 2
Min. process cycle time [ms] 6
Supported DeviceIDs
Type of operation DeviceID
default 810
Operating conditions
Ambient temperature [°C] -10...60
Protection IP 67
Tests / approvals
EMC
EN 60947-5-2
Laser protection class 2
Notes on laser protection
Caution: laser light
Power: <= 4,0 mW
Wave length: 650 nm
pulse: 1,3 ns
Do not stare into beam.
Avoid exposure to the laser light.
laser class: 2
EN / IEC60825-1:2007
EN / IEC60825-1:2014
Complies with 21 CFR 1040 except for deviations pursuant to Laser Notice No. 50, dated June 2007.
MTTF [years] 106
Mechanical data
Weight [g] 242.6
Housing rectangular
Dimensions [mm] 59 x 42 x 52
Materials housing: diecast zinc; front pane: glass; LED window: PC
Lens alignment side lens
Displays / operating elements
Display
switching status 2 x LED, yellow
operation LED, green
distance value, programming alphanumeric display, 4-digit
Remarks
Remarks
operating voltage "supply class 2" according to cULus
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; coding: A
Other data
Parameter Setting range Factory setting
Uni m, feet m
OU1 Hno, Hnc, Fno, Fnc Hno
SP1 1.00...75.00 10.00
nSP1 1.00...75.00 8.00
FSP1 1.00...75.00 12.00
OU2 Hno, Hnc, Fno, Fnc, I, U I
SP2 1.00...75.00 20.00
nSP2 1.00...75.00 18.00
FSP2 1.00...75.00 22.00
ASP 0...75.00 0
AEP 0...75.00 75.00
rATE [Hz] 1...33 15
dS1 0...0.1...5 0
dr1 0...0.1...5 0
dS2 0...0.1...5 0
dr2 0...0.1...5 0
dFo 0...0.1...5 0.2
dIS d1...3; rd1...3; OFF d3
repeatability/accuracy
repeatability of the measured values accuracy
1...25 m ± 15 mm ± 35 mm
30 m ± 15 mm ± 35 mm
40 m ± 15 mm ± 35 mm
50 m ± 19 mm ± 39 mm
60 m ± 27 mm ± 47 mm
70 m ± 43 mm ± 63 mm
Sampling rate
Reflector 33 Hz
repeatability/accuracy
repeatability of the measured values accuracy
1...75 m ± 15 mm ± 35 mm
Sampling rate
Reflector 1 Hz
The values apply at
Extraneous light on the object < 100 klx
constant ambient conditions 23 °C / 960 hPa
minimum power-on time in minutes 10