For 8-pole sockets the core colours are not standardised.
Please note the wiring of the sensor and the sockets (see data sheet).

LR8010

Continuous level sensor (guided wave radar)

LR0000B-BR34AVPKG/US

{{'OPTIONAL_INFO' | productAvailability | error}}

Dear customer,
Unfortunately, this data sheet is not available in the requested language. If you have any further questions, you can contact us by e-mail.

Best regards
Your ifm team

  • For the reliable level control in tanks and containers
  • Suitable for water, oils and coolants
  • When used as overflow precention to Federal Water Act WHG § 19
  • Modular system consisting of evaluation unit and probe
  • Adaptation to different container heights through shortening of the probe
  • ce
  • whg
Download
Technische Details
Product characteristics
Number of inputs and outputs Number of digital outputs: 4
Probe length L [mm] 100...1600
Process connection G 3/4 external thread
Application
Special feature Gold-plated contacts
Installation Operation only in conjunction with rod and coaxial pipe.
Media hydrous coolants; oils; oil-based media; water; media similar to water
Dielectric constant of the medium ≥ 2
Cannot be used for See the operating instructions, chapter "Function and features".
Medium temperature [°C] 0...80
Tank pressure [bar] -0.5...4
Electrical data
Operating voltage [V] 18...30 DC
Current consumption [mA] < 65
Protection class III
Reverse polarity protection yes
Power-on delay time [s] < 3
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 4
Outputs
Total number of outputs 4
Output signal switching signal
Electrical design PNP
Number of digital outputs 4
Output function normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V] 2.5
Permanent current rating of switching output DC [mA] 200
Short-circuit protection yes
Type of short-circuit protection thermal, pulsed
Overload protection yes
Measuring/setting range
Probe length L [mm] 100...1600
Active range A [mm] L-40 (L-60); (when set to oil and oil based media)
Inactive range I1 / I2 [mm] 30 / 10 (30); (when set to oil and oil based media)
Setting range
Set point SP [mm] ≥ 15 (35) / ≤ L-30
Note on setpoint SP
when set to oil and oil based media
Reset point rP [mm] ≥ 10 (30) / ≤ L-35
Note on reset point rP
when set to oil and oil based media
In steps of [mm] 5
Hysteresis [mm] > 5
Overflow switch point OP [mm] 70...L-30
Hysteresis, OP [mm] 10
Accuracy / deviations
Repeatability [mm] ± 5
Switch point accuracy [mm] ± (15 + 0,5 % ); (% of the final value of the measuring range: L - 30 mm)
Operating conditions
Ambient temperature [°C] 0...60
Storage temperature [°C] -25...80
Protection IP 67
Tests / approvals
Approval WHG § 19
EMC
DIN EN 61000-6-2
DIN EN 61000-6-4
Shock resistance
DIN EN 60068-2-27 50 g (11 ms)
Vibration resistance
DIN EN 60068-2-6 5 g (10...2000 Hz)
MTTF [years] 183
Mechanical data
Weight [g] 402
Materials stainless steel (1.4404 / 316L); stainless steel (1.4301 / 304); FKM; PBT-GF20; PC; PEI; TPV
Materials (wetted parts) stainless steel (1.4305 / 303); probe connection: stainless steel (1.4435 / 316L); PTFE; FKM; Sealing: NBR-PPTA 20
Process connection G 3/4 external thread
Displays / operating elements
Display
Display unit 3 x LED, green
switching status 4 x LED, yellow
level alphanumeric display, 4-digit
parameter setting alphanumeric display, 4-digit
Remarks
Notes For 8-pole sockets the core colours are not standardised.; Please note the wiring of the sensor and the sockets (see data sheet).
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; Contacts: gold-plated
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — LR8010-00 — 10.09.2013 —