You probably do not come from: Germany. If necessary, change to: United States
ifm-Service-Center 0800 16 16 16 4
  1. Products
  2. IO-Link
  3. IO-Link accessories / connection technology
  4. IO-Link converter
  5. DP2122

speed monitor IO-Link - 0...2000 Hz

DP2122

Monitoring Display-Speed

speed monitor IO-Link - 0...2000 Hz

DP2122

Monitoring Display-Speed

  • ce
  • ukca
  • iolink
  • cul
Product characteristics
Number of inputs and outputs Number of digital inputs: 1; Number of digital outputs: 2
Communication interface IO-Link
DP2122_FREQ / CMPT = 1
Measuring range [Hz] 0.1...2000
DP2122_REVL / CMPT = 2
Measuring range [U/min] 1...120000
Electrical data
Operating voltage [V] 18...30 DC; (to SELV/PELV)
Nominal voltage DC [V] 24
Current consumption [mA] < 380
Max. current load total [A] 0.2
Inputs / outputs
Number of inputs and outputs Number of digital inputs: 1; Number of digital outputs: 2
Inputs
Number of digital inputs 1; (IEC61131-2)
Input current limitation [mA] 200
Outputs
Electrical design PNP/NPN
Number of digital outputs 2
Output function normally open / normally closed; (parameterisable)
Short-circuit proof yes
Measuring/setting range
DP2122_FREQ / CMPT = 1
Measuring range [Hz] 0.1...2000
DP2122_REVL / CMPT = 2
Measuring range [U/min] 1...120000
Accuracy / deviations
Hysteresis [%] 0.5...100
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
Profiles Smart Sensor: Measuring Sensor (High resolution, Disable function); Identification and Diagnosis; Switching Signal Channel; Adjustable Switching Signal Channel
SIO mode yes
Required master port type A
Process data binary 1
Min. process cycle time [ms] 4.3
Supported DeviceIDs
Type of operation DeviceID
FREQ / CMPT = 1 1167
REVL / CMPT = 2 1294
Operating conditions
Ambient temperature [°C] -25...60
Note on ambient temperature
2000 m: -25...60 °C
3000 m: -25...53 °C
4000 m: -25...51 °C
Storage temperature [°C] -25...60
Max. relative air humidity [%] 90; (linearly decreasing to 50 % (40 °C) non condensing)
Max. height above sea level [m] 4000
Protection IP 67
Pollution degree 2
Tests / approvals
MTTF [years] 317
Mechanical data
Weight [g] 83.8
Weight (without accessories and packaging) [g] 35
Dimensions [mm] 63 x 30 x 24
Materials housing: PA
Displays / operating elements
Display
operation 1 x LED, green
7-segment LED display, green/red configurable
Operating elements
2 push ring
Accessories
Accessories (optional)
mounting clip
Remarks
Remarks
For further information please see the operating instructions.
Pack quantity 1 pcs.