Product characteristics |
Number of inputs and outputs |
Number of digital outputs: 2; Number of analogue outputs: 1 |
Process connection |
threaded connection G 1/4 DN8 |
Pressure monitoring |
Measuring range [bar] |
-1...16 |
Application |
Application |
for industrial applications |
Media |
compressed air |
Medium temperature [°C] |
-10...60 |
Min. bursting pressure [bar] |
64 |
Min. bursting pressure [MPa] |
6.4 |
Pressure rating [bar] |
16 |
Pressure rating [Mpa] |
1.6 |
Electrical data |
Operating voltage [V] |
18...30 DC; (to SELV/PELV) |
Current consumption [mA] |
< 80 |
Protection class |
III |
Reverse polarity protection |
yes |
Power-on delay time [s] |
1 |
Inputs / outputs |
Number of inputs and outputs |
Number of digital outputs: 2; Number of analogue outputs: 1 |
Inputs |
Inputs |
counter reset |
Outputs |
Output signal |
switching signal; analogue signal; pulse signal; IO-Link; (configurable) |
Electrical design |
PNP/NPN |
Number of digital outputs |
2 |
Output function |
normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V] |
2.5 |
Permanent current rating of switching output DC [mA] |
150; (per output) |
Number of analogue outputs |
1 |
Analogue current output [mA] |
4...20; (scalable) |
Max. load [Ω] |
500 |
Pulse output |
consumed quantity meter |
Short-circuit protection |
yes |
Type of short-circuit protection |
pulsed |
Overload protection |
yes |
Measuring/setting range |
Measuring range |
0.8...250 l/min |
0.3...82.9 m/s |
0.05...15 m³/h |
|
Display range |
0...300 l/min |
0...99.5 m/s |
0...18 m³/h |
|
Resolution |
0.2 l/min |
0.1 m/s |
0.01 m³/h |
|
Set point SP |
2.2...249.9 l/min |
0.7...82.9 m/s |
0.13...14.99 m³/h |
|
Reset point rP |
0.9...248.7 l/min |
0.3...82.5 m/s |
0.06...14.92 m³/h |
|
Analogue start point ASP |
0...200 l/min |
0...66.3 m/s |
0...12 m³/h |
|
Analogue end point AEP |
50...250 l/min |
16.6...82.9 m/s |
3...15 m³/h |
|
Low flow cut-off LFC |
0.3...2.7 l/min |
0.1...0.9 m/s |
0.02...0.16 m³/h |
|
In steps of |
0.1 l/min |
0.1 m/s |
0.01 m³/h |
|
Pressure monitoring |
Measuring range [bar] |
-1...16 |
Display range [bar] |
-1...20 |
Resolution [bar] |
0.05 |
Set point SP [bar] |
-0.92...16 |
Reset point rP [bar] |
-1...15.92 |
Analogue start point [bar] |
-1...12.8 |
Analogue end point [bar] |
2.2...16 |
In steps of [bar] |
0.01 |
Volumetric flow quantity monitoring |
Measuring range |
0...100000000 m³ |
0...353146667.2 scf |
|
Display range |
0...100000000 m³ |
0...353146667.2 scf |
|
Set point SP |
0.001...10000000 m³ |
0.05...353146667.2 scf |
|
Pulse value |
0.001...10000000 m³ |
0.05...353146667.2 scf |
|
In steps of |
|
Pulse length [s] |
0.01...2 |
Temperature monitoring |
Measuring range |
|
Display range |
-24...74 °C |
-11.2...165.2 °F |
|
Resolution |
|
Set point SP |
-9.7...60 °C |
14.6...140 °F |
|
Reset point rP |
-10...59.7 °C |
14...139.4 °F |
|
Analogue start point |
-10...46 °C |
14...114.8 °F |
|
Analogue end point |
|
In steps of |
|
Accuracy / deviations |
Temperature coefficient [1/K] |
± 0,07 % MW |
Accuracy (in the measuring range) |
class 141: ± (2 % MW + 0,5 % MEW); class 344: ± (6 % MW + 0,6 % MEW) ; air quality to ISO 8573-1:2010; at medium temperature 23 °C |
Repeatability |
± (0,4 % MW + 0,1 % MEW) |
Pressure monitoring |
Repeatability [% of the final value] |
± 0,2 |
Characteristics deviation [% of the final value] |
< ± 0,5; (BFSL = Best Fit Straight Line) |
Greatest TEMPCO of the span [% MEW / 10 K] |
± 0,3 |
Greatest TEMPCO of the zero point [% MEW / 10 K] |
± 0,1 |
Temperature monitoring |
Accuracy [K] |
± 0,5; (medium flow in the limit area of the flow measurement range) |
Response times |
Response time [s] |
0.1; (dAP = 0) |
Damping process value dAP [s] |
0...5 |
Pressure monitoring |
Response time [s] |
0.05 |
Temperature monitoring |
Dynamic response T05 / T09 [s] |
T09 = 0,5 |
Software / programming |
Parameter setting options |
hysteresis / window; normally open / normally closed; current/pulse output; display can be rotated and switched off; Display unit; totaliser |
Interfaces |
Communication interface |
IO-Link |
Transmission type |
COM2 (38,4 kBaud) |
IO-Link revision |
1.1 |
SDCI standard |
IEC 61131-9 CDV |
Profiles |
Digital Measuring Sensor (0x800A), Identification and Diagnosis (0x4000) |
SIO mode |
yes |
Required master port type |
A |
Process data analogue |
8 |
Process data binary |
2 |
Min. process cycle time [ms] |
7.2 |
Supported DeviceIDs |
Type of operation |
DeviceID |
Default |
860 |
|
Operating conditions |
Ambient temperature [°C] |
0...60 |
Storage temperature [°C] |
-20...85 |
Max. relative air humidity [%] |
90 |
Protection |
IP 65; IP 67 |
Tests / approvals |
EMC |
|
CPA approval |
model number |
001TG |
accuracy class |
- |
maximum allowable error |
± 2,5 % FS |
Q (min) |
0,05 m³/h |
Q (t) |
- |
Q (max) |
15 m³/h |
|
Vibration resistance |
DIN EN 68000-2-6 |
5 g (10...2000 Hz) |
|
MTTF [years] |
183 |
UL approval |
UL Approval no. |
I012 |
File number UL |
E174189 |
|
Pressure Equipment Directive |
Sound engineering practice; can be used for stable gases fluid group 2 |
Mechanical data |
Weight [g] |
556 |
Materials |
PBT+PC-GF30; PPS GF40; stainless steel (1.4301 / 304); stainless steel (1.4305 / 303); steel (1.5523) galvanised; 2.0401 (brass / CW614N); FKM |
Materials (wetted parts) |
EN AW-6082 (aluminium); stainless steel (1.4305 / 303); FKM; ceramics glass passivated; PPS GF40; Al2O3 (ceramics); acrylate |
Process connection |
threaded connection G 1/4 DN8 |
Displays / operating elements |
Display |
|
colour display 1,44", 128 x 128 pixels |
|
2 x LED, yellow |
|
Remarks |
Remarks |
MW = measured value |
MEW = Final value of the measuring range |
Measuring, display and setting ranges refer to the standard volume flow according to DIN ISO 2533. |
For information about installation and operation please see the operating instructions. |
|
Pack quantity |
1 pcs. |
Electrical connection |
Connection |
Connector: 1 x M12; coding: A |