1. Homepage
  2. Products
  3. Sensors for motion control
  4. Sensors for conveyor monitoring
  5. 3D sensors
  6. O3D314

O3D314

3D sensor

O3DIRDKG/E1/GM/W/70

{{'OPTIONAL_INFO' | productAvailability | error}}

Dear customer,
Unfortunately, this data sheet is not available in the requested language. If you have any further questions, you can contact us by e-mail.

Best regards
Your ifm team

Comprehensive technical data in pdf format

Technische Details
Product characteristics
Image resolution 3D [pixels] 176 x 132
Angle of aperture 3D [°] 70 x 51; (nominal value without lens distortion correction)
Max. reading rate [Hz] 25
Dimensions [mm] 72 x 67.1 x 82.6
Application
Application dimensioning of the object; completeness monitoring; Level monitoring; distance monitoring; volume monitoring
Electrical data
Operating voltage [V] 20.4...28.8 DC; (EN 61131-2)
Current consumption [mA] < 2400; (peak current pulsed; typical value: 420; maximum value: 1600)
Power consumption [W] 10; (typical value)
Protection class III; (PELV)
Image sensor PMD 3D ToF-Chip
Internal lighting yes
Inputs / outputs
Number of inputs and outputs Number of digital inputs: 2; Number of digital outputs: 3; Number of analogue outputs: 1
Inputs
Number of digital inputs 2
Trigger 24 V PNP/NPN (IEC 61131-2 Typ 3)
Input circuit of digital inputs 24 V PNP/NPN; (configurable; IEC 61131-2 Typ 3)
Outputs
Total number of outputs 3
Number of digital outputs 3; (configurable)
Output function 24 V PNP/NPN; (EN 61131-2)
Max. voltage drop switching output DC [V] 1
Max. current load per output [mA] 100
Number of analogue outputs 1
Analogue current output [mA] 4...20
Max. load [Ω] 500
Analogue voltage output [V] 0...10
Min. load resistance [Ω] 10000
Short-circuit protection yes
Type of short-circuit protection pulsed
Overload protection yes
Detection zone
Operating distance [mm] 300...8000
Note on operating distance
object size: 200 x 200 mm
reflectivity: 18 %
Image resolution 3D [pixels] 176 x 132
Angle of aperture 3D [°] 70 x 51; (nominal value without lens distortion correction)
Max. reading rate [Hz] 25
Measuring/setting range
Measuring range [m] < 30
Software / programming
Parameter setting options via PC with ifm Vision Assistant
Interfaces
Communication interface Ethernet
Ethernet
Number of Ethernet interfaces 1
Transmission standard 10Base-T; 100Base-TX
Transmission rate 10; 100
Protocol TCP/IP; PROFINET IO; EtherNet/IP
Factory settings
IP address: 192.168.0.69
subnet mask: 255.255.255.0
gateway IP address: 192.168.0.201
Operating conditions
Ambient temperature [°C] -10...50
Storage temperature [°C] -40...85
Protection IP 65; IP 67; IP 69K
Max. immunity to extraneous light [klx] 8; (with reduced measuring accuracy and repeatability: < 100)
Tests / approvals
EMC
DIN EN 61000-6-4 radiation of interference / industrial environments
DIN EN 61000-6-2 noise immunity / industrial environments
Shock resistance
DIN EN 60068-2-27 50 g / (11 ms) not repetitive
DIN EN 60068-2-27 40 g / (6 ms) repetitive
Vibration resistance
DIN EN 60068-2-6 2 g / (10...150 Hz)
DIN EN 60068-2-64 2.3 g RMS / (10...500 Hz)
Photobiological safety exempt group; (DIN EN 62471)
Electrical protection
DIN EN 61010-2-201 electrical supply only via PELV circuits
Mechanical data
Weight [g] 1137.5
Dimensions [mm] 72 x 67.1 x 82.6
Materials housing: stainless steel (1.4404 / 316L); front lens: Gorilla Glass; function display: PA
Displays / operating elements
Display
function 2 LED, green Ethernet operation
switching status 2 LED, yellow OUT 1 OUT 2
Accessories
Accessories (supplied)
USB memory stick with software and documentation
Protective covers
Remarks
Pack quantity 1 pcs.
Electrical connection - Ethernet
Connector: 1 x M12
Electrical connection - Process connection
Connector: 1 x M12
Other data
field of view size with lens distortion correction
measuring range / distance [m] Length [m] Width [m]
0.50 0.40 0.55
1.00 0.80 1.10
2.00 1.60 2.20
3.00 2.40 3.30
4.00 3.20 4.40
5.00 4.00 5.50
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — O3D314-00 — 21.02.2019 —