Technische Details
Application
Media hydrous coolants; oils; oil-based media; water; media similar to water
Dielectric constant of the medium > 2
Cannot be used for extremely conductive media; adhering media; granulates; bulk material; acids; alkali
Tank pressure [bar] 0.5; (when mounting with mounting accessories: E43001 - E43007, E43019)
coolants
Medium temperature [°C] 0...35; (with climatic tube E43102)
oil
Medium temperature [°C] 0...70
Medium temperature short time [°C] 0...90; (< 1 h)
water
Medium temperature [°C] 0...35; (with climatic tube E43102 35...55 °C)
Electrical data
Operating voltage [V] 18...30 DC
Current consumption [mA] < 50
Protection class III
Reverse polarity protection yes
Power-on delay time [s] < 3
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 1; Number of analogue outputs: 1
Outputs
Total number of outputs 2
Output signal switching signal; analogue signal; IO-Link
Electrical design PNP/NPN
Number of digital outputs 1
Output function normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V] 2.5
Permanent current rating of switching output DC [mA] 200
Number of analogue outputs 1
Analogue current output [mA] 4...20, invertible
Max. load [Ω] 500
Analogue voltage output [V] ...10, invertible
Min. load resistance [Ω] 2000
Short-circuit protection yes
Type of short-circuit protection thermal, pulsed
Overload protection yes
Measuring/setting range
Factory setting mineral oils
Probe length L [mm] 728
Active range A [mm] 585
Inactive range I1 / I2 [mm] 104 / 39
Setting range
Set point SP [mm] 60...590
Reset point rP [mm] 50...580
In steps of [mm] 10
Reference point OP [mm] 200 - 240 - 280 - 310 - 350 - 390 - 420 - 460 - 500 - 530 - 570 - 610 - OFF
Hysteresis, OP [mm] 4
Temperature monitoring
Measuring range [°C] 0...90
Set point SP [°C] 0.5...90
Reset point rP [°C] 0...89.5
In steps of [°C] 0.5
Resolution of switching output [K] 0.5
Accuracy / deviations
Measuring error [% of the final value] ± 5
Repeatability ± 2
Resolution [mm] 5
Zero signal (voltage) [V] 0
Zero signal (current) [mA] 4.0
Full signal (voltage) [V] 10
Full signal (current) [mA] 20
Temperature monitoring
Switch point accuracy [K] ± 1,5
Resolution [K] 0.5
Dynamic response T09 [s] 90
Software / programming
Parameter setting options hysteresis / window; normally open / normally closed; switching logic; current/voltage output; SP/rP position; adjustment OP; medium selection; offset setting; switch-on/switch-off delay
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
IO-Link device ID 0x000288
Profiles Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis
SIO mode yes
Required master port type A
Process data analogue 4
Process data binary 1
Min. process cycle time [ms] 4.5
Operating conditions
Ambient temperature [°C] 0...60
Storage temperature [°C] -25...80
Protection IP 67
Tests / approvals
EMC
DIN EN 61000-6-2
DIN EN 61000-6-4
Shock resistance
DIN EN 60068-2-27 15 g (11 ms)
Vibration resistance
DIN EN 60068-2-6 5 g (10...2000 Hz)
MTTF [years] 222
UL approval
UL Approval no. H002
Mechanical data
Weight [g] 540.5
Dimensions [mm] Ø 16
Materials stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); FKM; NBR; PBT; PC; PA; PP; TPV
Materials (wetted parts) PP
Displays / operating elements
Display
Display unit 4 x LED, green (cm, inch, °C, °F)
switching status 1 x LED, yellow
measured values alphanumeric display, 4-digit
parameter setting alphanumeric display, 4-digit
Remarks
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12