Output function | normally open / normally closed; (selectable) |
---|---|
Sensing range [mm] | 20 |
Housing | rectangular |
Dimensions [mm] | 40 x 40 x 118 |
Operating voltage [V] | 20...250 AC/DC |
---|---|
Protection class | II |
Reverse polarity protection | yes |
Output function | normally open / normally closed; (selectable) |
---|---|
Max. voltage drop switching output DC [V] | 7 |
Max. voltage drop switching output AC [V] | 7 |
Minimum load current [mA] | 8 |
Max. leakage current [mA] | 2.5 |
Permanent current rating of switching output AC [mA] | 500 |
Permanent current rating of switching output DC [mA] | 500 |
Switching frequency AC [Hz] | 25 |
Switching frequency DC [Hz] | 25 |
Short-circuit protection | yes |
Overload protection | yes |
Sensing range [mm] | 20 |
---|---|
Real sensing range Sr [mm] | 20 ± 10 % |
Operating distance [mm] | 0...16.2 |
Correction factor | steel: 1 / stainless steel: 0.7 / brass: 0.4 / aluminium: 0.3 / copper: 0.2 |
---|---|
Hysteresis [% of Sr] | 1...15 |
Switch point drift [% of Sr] | -10...10 |
Ambient temperature [°C] | -25...70 |
---|---|
Protection | IP 67 |
EMC |
|
---|
Weight [g] | 258.4 |
---|---|
Housing | rectangular |
Mounting | non-flush mountable |
Dimensions [mm] | 40 x 40 x 118 |
Materials | PBT |
Display |
|
---|
Remarks |
|
|
---|---|---|
Pack quantity | 1 pcs. |
Connection | terminals: ...2.5 mm²; Cable gland: M20 X 1.5 |
---|