You probably do not come from: Canada. If necessary, change to: United States
Service hotline 855-436-2262
  1. Products
  2. Sensors
  3. Encoders
  4. Incremental encoders
  5. RO3110

Incremental encoder with hollow shaft

RO3110

INCREMENTAL ENCODER

Incremental encoder with hollow shaft

RO3110

INCREMENTAL ENCODER

  • ce
  • ukca
  • iolink
  • cul
Product characteristics
Resolution 1...10000; (parameterisable; Factory setting: 1024) resolution
Communication interface IO-Link
Shaft design hollow shaft open to one side
Shaft diameter [mm] 15
Application
Function principle incremental
Detection system magnetic
Electrical data
Operating voltage [V] 4.75...30 DC
Current consumption [mA] < 150
Protection class III
Reverse polarity protection yes
Power-on delay time [s] 0.5
Max. revolution electrical [U/min] 12000
Outputs
Electrical design HTL/TTL
Switching frequency [kHz] 1000
Factory setting
Output function: HTL (50 mA)
Short-circuit protection yes
Phase difference A and B [°] 90
Measuring/setting range
Resolution 1...10000; (parameterisable; Factory setting: 1024) resolution
Accuracy / deviations
Accuracy [°] 0.1
Software / programming
Parameter setting options Resolution; direction of rotation; HTL; TTL
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SIO mode yes
Min. process cycle time [ms] 2.3
Operating conditions
Ambient temperature [°C] -40...85
Storage temperature [°C] -40...85
Max. relative air humidity [%] 95; (condensation not permissible)
Protection IP 67; (on the housing: IP 67; on the shaft: IP 67)
Tests / approvals
Shock resistance
100 g
Vibration resistance
20 g
MTTF [years] 292
Mechanical data
Weight [g] 665
Dimensions [mm] Ø 58.5
Materials flange: stainless steel (1.4571/316Ti ); housing: stainless steel (1.4521 / 444); NBR
Tightening torque [Nm] < 0.7; (Mounting screw)
Max. revolution, mechanical [U/min] 12000
Max. starting torque [Nm] 2
Reference temperature torque [°C] 20
Shaft design hollow shaft open to one side
Shaft diameter [mm] 15
Shaft material
stainless steel (1.4571/316Ti )
Installation depth of shaft [mm] 27
Max. axial shaft misalignment [mm] 0,5
Fixing flange Ø 58.5 mm
Electrical connection
IO-Link Connector: 1 x M12, radial, can also be used axially; coding: A; Moulded body: stainless steel (316 / 1.4401); Maximum cable length: 100 m; (IO-Link: max. 20 m)
Diagrams and graphs
Pulse diagram
direction of rotation clockwise (looking at the shaft)