Application |
Media |
hydrous coolants; oils; water; media similar to water |
Dielectric constant of the medium |
> 2 |
Cannot be used for |
extremely conductive media; adhering media; granulates; bulk material; acids; alkali |
Tank pressure [bar] |
0.5; (only for applications without pressure) |
Coolants |
Medium temperature [°C] |
0...35 |
Oil |
Medium temperature [°C] |
0...65 |
Water |
Medium temperature [°C] |
0...35 |
Electrical data |
Operating voltage [V] |
12...30 DC |
Current consumption [mA] |
< 60 |
Protection class |
III |
Reverse polarity protection |
yes |
Power-on delay time [s] |
3 |
Inputs / outputs |
Number of inputs and outputs |
Number of digital outputs: 2 |
Outputs |
Total number of outputs |
2 |
Output signal |
switching signal |
Electrical design |
PNP |
Number of digital outputs |
2 |
Output function |
normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V] |
2.5 |
Permanent current rating of switching output DC [mA] |
200 |
Short-circuit protection |
yes |
Type of short-circuit protection |
pulsed |
Overload protection |
yes |
Measuring/setting range |
Probe length L [mm] |
264 |
Active range A [mm] |
195 |
Inactive range I1 / I2 [mm] |
53 / 15 |
Setting range |
Set point SP [mm] |
25...190 |
Reset point rP [mm] |
20...185 |
In steps of [mm] |
5 |
Hysteresis [mm] |
5 |
Overflow switch point OP [mm] |
69 - 82 - 94 - 106 - 118 - 130 - 143 - 155 - 167 - 179 - 191 - 204 |
Hysteresis, OP [mm] |
2 |
Accuracy / deviations |
Measuring error [% of the final value] |
± 5 |
Repeatability |
± 2 |
Software / programming |
Parameter setting options |
hysteresis / window; normally open / normally closed; SP/rP position; OP position; adjustment OP; medium selection; offset setting; Display unit |
Operating conditions |
Ambient temperature [°C] |
0...60 |
Storage temperature [°C] |
-25...80 |
Protection |
IP 67 |
Tests / approvals |
Approval |
WHG § 19 |
EMC |
EN 61000-4-2 ESD |
4 kV CD / 8 kV AD |
EN 61000-4-3 HF radiated |
10 V/m |
EN 61000-4-4 Burst |
2 kV |
EN 61000-4-5 Surge |
500 V / 1 kV |
EN 61000-4-6 HF conducted |
10 V |
|
Shock resistance |
DIN EN 60068-2-29 |
12 g (11 ms) |
|
Vibration resistance |
DIN EN 60068-2-6 |
2.5 g (10...2000 Hz) |
|
MTTF [years] |
266 |
Mechanical data |
Weight [g] |
510 |
Dimensions [mm] |
Ø 16 |
Materials |
EPDM/X; FKM; brass white bronze coated; NBR; PBT; PC; PP; PA |
Materials (wetted parts) |
PP |
Displays / operating elements |
Display |
switching status |
2 x LED, red |
measured values |
7-segment LED display |
parameter setting |
7-segment LED display |
|
Remarks |
Notes |
Please see the technical note under "Downloads" |
Pack quantity |
1 pcs. |
Electrical connection |
Connection |
Connector: 1 x M12; Contacts: gold-plated |