  5. SF120A

Flow sensor for connection to an evaluation unit

SF120A

SFM12ABB/US/2G

Flow sensor for connection to an evaluation unit

SF120A

SFM12ABB/US/2G

  • For applications in hazardous areas
  • Reliable monitoring of liquids and gases in pipes
  • For connection to an evaluation unit
  • Robust design for use in harsh industrial environments
  • M12 connector for fast and easy connection
  • ce
  • ukca
  • ex
  • iec
Product characteristics
Probe length L [mm] 12
Process connection M12 x 1
Application
Media Liquids; Gases
Medium temperature [°C] -20...70
Pressure rating [bar] 30
Liquids
Medium temperature [°C] -20...70
Gases
Medium temperature [°C] -20...70
Electrical data
Connection to control monitor VS2000 Exi (PTB 01 ATEX 2075)
Measuring/setting range
Probe length L [mm] 12
Liquids
Setting range [cm/s] 3...300
Greatest sensitivity [cm/s] 3...60
Gases
Setting range [cm/s] 200...2000
Greatest sensitivity [cm/s] 200...800
Accuracy / deviations
Temperature gradient [K/min] 15
Response times
Response time [s] 1...10
Liquids
Response time [s] 1...10
Gases
Response time [s] 1...10
Operating conditions
Ambient temperature [°C] -20...70
Protection IP 67
Tests / approvals
Approval DMT 03 ATEX E091; IECEX BVS 06.0007
ATEX marking II 2G Ex ia IIC T4 Gb
Shock resistance
DIN IEC 68-2-27 40 g (11 ms)
Vibration resistance
DIN IEC 68-2-6 10 g (55...2000 Hz)
MTTF [years] 8648
Safety classification
Max. internal capacitance [nF] 0.4
Max. internal inductance [µH] 2
Temperature class T4
Mechanical data
Weight [g] 111.5
Housing threaded type
Dimensions [mm] M12 x 1
Thread designation M12 x 1
Materials stainless steel (1.4404 / 316L)
Materials (wetted parts) stainless steel (1.4404 / 316L)
Process connection M12 x 1
Installation length EL [mm] 27
Remarks
Remarks
In principle, the type test according to 94/9/EC (ATEX) only takes atmospheric conditions into account (0.8...1.1 bar).
For pressures outside this range use must be assessed and approved by the user.
Adhere to the operating instructions and the type test certificate.
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; coding: A; Maximum cable length: 100 m