Product characteristics
Output function | normally open / normally closed; (programmable) |
---|---|
Sensing range [mm] | 40 |
Housing | rectangular |
Dimensions [mm] | 40 x 40 x 105 |
Electrical data
Frequency AC [Hz] | 45...65 |
---|---|
Operating voltage [V] | 20...250 AC/DC |
Protection class | II |
Reverse polarity protection | yes |
Outputs
Output function | normally open / normally closed; (programmable) | |
---|---|---|
Max. voltage drop switching output DC [V] | 5.5 | |
Max. voltage drop switching output AC [V] | 5.5 | |
Minimum load current [mA] | 5 | |
Max. leakage current [mA] | 2.5 (250 V AC) / 1.3 (130 V AC) / 0.8 (24 V DC) | |
Permanent current rating of switching output AC [mA] | 100 | |
Permanent current rating of switching output DC [mA] | 100 | |
Short-time current rating of switching output [mA] | î: 0,6 A (20 ms / 0,5 Hz) | |
Switching frequency AC [Hz] | 10 | |
Switching frequency DC [Hz] | 10 | |
Notes on switching frequency [Hz] |
|
|
Type of short-circuit protection | pulsed | |
Short-circuit proof | yes | |
Overload protection | yes |
Detection zone
Sensing range [mm] | 40 |
---|---|
Real sensing range Sr [mm] | 40 ± 10 % |
Operating distance [mm] | 0...32.4 |
Accuracy / deviations
Correction factor | steel: 1 / stainless steel: 0.7 / brass: 0.4 / aluminium: 0.3 / copper: 0.2 |
---|---|
Hysteresis [% of Sr] | 1...20 |
Switch point drift [% of Sr] | -10...10 |
Operating conditions
Ambient temperature [°C] | -25...80 |
---|---|
Protection | IP 65; IP 67 |
Tests / approvals
EMC |
|
---|
Mechanical data
Weight [g] | 237.8 |
---|---|
Housing | rectangular |
Mounting | non-flush mountable |
Dimensions [mm] | 40 x 40 x 105 |
Materials | PC; PA; stainless steel |
Displays / operating elements
Display |
|
---|
Remarks
Pack quantity | 1 pcs. |
---|
Electrical connection
Connection | screw terminals: 0.34...2.5 mm²; Cable sheath: Ø 5...9 mm |
---|