1. Homepage
  2. Products
  3. TA3337

Article no longer available - archive entry

Replaced by: TA3317 – Product comparison: TA3337 / TA3317
discontinued article
discontinued article
Date of discontinuation: {{"2017-03-31T00:00:00.000+02:00" | date}}

Temperature transmitter

TA-060CLDN14-A-ZVG/US/

TA3337

{{'OPTIONAL_INFO' | productAvailability | error}}

Dear customer,
Unfortunately, this data sheet is not available in the requested language. If you have any further questions, you can contact us by e-mail.

Best regards
Your ifm team


List Price without Tax in ARS

  • High precision across the entire temperature measurement range
  • Particularly good response dynamics and very short power-on delay time
  • Robust stainless steel housing with very high pressure rating
  • Precise analogue output
  • High protection rating for the requirements of harsh industrial environments
  • ce
  • cul
Download
Technische Details
Application
Measuring element 1 x Pt 1000; (to DIN EN 60751, class A)
Media liquids and gases
Medium temperature
< 150; (< 40 min) °C < 302; (< 40 min) °F
Pressure rating [bar] 300
Minimum installation depth [mm] 15
Electrical data
Operating voltage [V] 10...30 DC
Protection class III
Reverse polarity protection yes
Inputs / outputs
Number of inputs and outputs Number of analogue outputs: 1
Outputs
Total number of outputs 1
Output signal analogue signal
Number of analogue outputs 1
Analogue current output [mA] 4...20
Max. load [Ω] 500
Overload protection yes
Measuring/setting range
Probe length L [mm] 46.5
Measuring range
0...100 °C 32...212 °F
Resolution
Resolution of analogue output [K] 0.02
Accuracy / deviations
Precision analogue output [K] ± 0,3
Temperature coefficient [% of the span / 10 K] < ± 0,1; (in case of deviation from the reference condition 25 ± 5 °C)
Response times
Dynamic response T05 / T09 [s] 1 / 3; (to DIN EN 60751)
Operating conditions
Ambient temperature [°C] -25...70
Storage temperature [°C] -40...100
Protection IP 68; IP 69K
Tests / approvals
EMC
DIN EN 61000-4-2 ESD 4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated 10 V/m
DIN EN 61000-4-4 Burst 2 kV
DIN EN 61000-4-5 Surge 1 kV
EN 61000-4-6 HF conducted 10 V
Shock resistance
DIN EN 60068-2-27 50 g (11 ms)
Vibration resistance
DIN EN 60068-2-6 10 g (10...2000 Hz)
MTTF [years] 1119
Mechanical data
Weight [g] 124.2
Dimensions [mm] Ø 30 / L = 117.7
Materials stainless steel (1.4404 / 316L); stainless steel (1.4301 / 304); stainless steel (1.4305 / 303); PA
Materials (wetted parts) stainless steel (1.4404 / 316L)
Process connection threaded connection 1/4" NPT
Installation length EL [mm] 60
Remarks
Remarks
operating voltage "supply class 2" according to cULus
The values for accuracy apply to flowing water.
Notes discontinued article
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; Contacts: gold-plated
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — TA3337-00 — 09.05.2012 —