Application |
Media |
water |
Medium temperature [°C] |
-10...60; (In case of medium temperatures < 4 °C the data refer to water / glycol (40 % glycol).) |
Pressure rating [bar] |
25 |
Electrical data |
Operating voltage tolerance [%] |
-15...15 |
Operating voltage [V] |
24 DC |
Current consumption [mA] |
< 50 |
Protection class |
III |
Power-on delay time [s] |
15 |
Outputs |
Output signal |
frequency signal |
Electrical design |
PNP |
Max. voltage drop switching output DC [V] |
0.8 |
Permanent current rating of switching output DC [mA] |
80 |
Short-circuit protection |
no |
Overload protection |
no |
Measuring/setting range |
Note on measuring range |
for water (20 °C) and mounting in 2" pipe |
|
Frequency end point, FEP [cm/s] |
5...70 |
Frequency at the end point FRP [Hz] |
5...70 |
Response times |
Response time [s] |
1...10 |
Operating conditions |
Ambient temperature [°C] |
-20...70 |
Storage temperature [°C] |
-40...70 |
Protection |
IP 67 |
Tests / approvals |
Shock resistance |
DIN EN 60068-2-27 |
50 g (11 ms) |
|
Vibration resistance |
DIN EN 60068-2-6 |
20 g (10...2000 Hz) |
|
MTTF [years] |
524 |
Mechanical data |
Weight [g] |
124.5 |
Materials |
stainless steel (1.4404 / 316L) |
Materials (wetted parts) |
stainless steel (1.4404 / 316L) |
Process connection |
1/2 NPT |
Remarks |
Pack quantity |
1 pcs. |
Electrical connection |
Connection |
Connector: 1 x M12 |