You probably do not come from: South Africa. If necessary, change to: United States
  1. Products
  2. Sensors
  3. Capacitive sensors
  4. All capacitive sensors
  5. KD001A

Capacitive sensor

KD001A

KDE2060-FBOA/NI/3D

Capacitive sensor

KD001A

KDE2060-FBOA/NI/3D

  • With combined AC/DC output and two-wire technology
  • Long sensing range of 60 mm
  • Easy setting of the sensing range via potentiometer
  • For applications in hazardous areas
  • Robust housing for use in harsh industrial environments
  • ce
  • ukca
  • ex
Product characteristics
Output function normally open / normally closed; (selectable)
Sensing range [mm] 60
Housing rectangular
Dimensions [mm] 105 x 80 x 42
Electrical data
Operating voltage [V] 20...250 AC/DC
Protection class II
Reverse polarity protection no
Measuring principle capacitive
Outputs
Output function normally open / normally closed; (selectable)
Max. voltage drop switching output DC [V] 8
Max. voltage drop switching output AC [V] 10
Minimum load current [mA] 5
Max. leakage current [mA] 2.5 (250 V AC) / 1.7 (110 V AC) / 1.3 (24 V DC)
Permanent current rating of switching output AC [mA] 130; (250 (...40 °C))
Permanent current rating of switching output DC [mA] 130; (250 (...40 °C))
Short-time current rating of switching output [mA] 1500; (20 ms / 0,5 Hz)
Switching frequency AC [Hz] 4
Switching frequency DC [Hz] 4
Notes on switching frequency [Hz]
only for resistive loads; 2 Hz for utilisation category AC-140
Short-circuit proof no
Overload protection no
Detection zone
Sensing range [mm] 60
Sensing range adjustable yes
Factory setting sensing range [mm] 60
Real sensing range Sr [mm] 60 ± 10 %
Accuracy / deviations
Correction factor glass: 0.4 / water: 1 / ceramics: 0.2 / PVC: 0.2
Hysteresis [% of Sr] 1...15
Switch point drift [% of Sr] -15...15
Operating conditions
Ambient temperature [°C] -20...60
Protection IP 65
Increased immunity yes
Tests / approvals
ATEX marking II 3D Ex tc IIIC T90°C Dc X IP65
EMC
EN 60947-5-2
MTTF [years] 270
Mechanical data
Weight [g] 281.5
Housing rectangular
Mounting non-flush mountable
Dimensions [mm] 105 x 80 x 42
Materials PPE modified; PA
Tightening torque [Nm] housing screws: 0,9 Nm; screws: 4 Nm
Displays / operating elements
Display
switching status 1 x LED, yellow
Electrical connection
Required protection miniature fuse to IEC60127-2 sheet 1; ≤ 2 A; fast acting; Place the fuse outside the hazardous area.
Remarks
Remarks
Recommendation: Check the safe functioning of the unit after a short circuit.
Pack quantity 1 pcs.
Electrical connection
Connection terminals: 0.34...2.5 mm²; Cable sheath: Ø 5...9 mm; Cable gland: M20 X 1.5