Number of inputs and outputs | Number of digital outputs: 2; Number of analog outputs: 1 |
---|---|
Process connection | threaded connection 1/2" NPT DN15 |
Measuring range |
|
---|
Measuring range |
|
---|
Measuring range |
|
---|
Application | for industrial applications |
---|---|
Media | Argon (Ar); carbon dioxide (CO2); nitrogen (N2) |
Medium temperature [°F] | 32...140 |
Pressure rating [bar] | 16 |
Pressure rating [psi] | 232 |
MAWP (for applications according to CRN) [bar] | 16 |
Operating voltage [V] | 18...30 DC; (to SELV/PELV) |
---|---|
Current consumption [mA] | < 100 |
Protection class | III |
Reverse polarity protection | yes |
Power-on delay time [s] | 1 |
Number of inputs and outputs | Number of digital outputs: 2; Number of analog outputs: 1 |
---|
Total number of outputs | 2 |
---|---|
Output signal | switching signal; analog signal; pulse signal; IO-Link; (configurable) |
Electrical design | PNP |
Number of digital outputs | 2 |
Output function | normally open / closed; (configurable) |
Max. voltage drop switching output DC [V] | 2 |
Permanent current rating of switching output DC [mA] | 250; (per output) |
Number of analog outputs | 1 |
Analog current output [mA] | 4...20; (scalable) |
Max. load [Ω] | 500 |
Pulse output | consumed quantity meter |
Short-circuit protection | yes |
Type of short-circuit protection | yes (non-latching) |
Overload protection | yes |
Low flow cut-off LFC |
|
|||
---|---|---|---|---|
Measuring dynamics | 1:300 |
Pulse value | 0.040...4 000 000 scf |
---|---|
In steps of | 0.020...1000 scf |
Pulse length [s] | 0,007...2 |
Measuring range |
|
|||
---|---|---|---|---|
Display range |
|
|||
Resolution |
|
|||
Set point SP |
|
|||
Reset point rP |
|
|||
Analog start point ASP |
|
|||
Analog end point AEP |
|
|||
In steps of |
|
Measuring range |
|
|||
---|---|---|---|---|
Display range |
|
|||
Resolution |
|
|||
Set point SP |
|
|||
Reset point rP |
|
|||
Analog start point ASP |
|
|||
Analog end point AEP |
|
|||
In steps of |
|
Measuring range |
|
|||
---|---|---|---|---|
Display range |
|
|||
Resolution |
|
|||
Set point SP |
|
|||
Reset point rP |
|
|||
Analog start point ASP |
|
|||
Analog end point AEP |
|
|||
In steps of |
|
Measuring range [°F] | 32...140 |
---|---|
Display range [°F] | 10.5...161.5 |
Resolution [°F] | 0.5 |
Set point SP [°F] | 32.5...140 |
Reset point rP [°F] | 32...139.5 |
Analog start point [°F] | 32...118.5 |
Analog end point [°F] | 53.5...140 |
In steps of [°F] | 0.5 |
Repeatability [% of the measured value] | ± 1,5 |
---|---|
Accuracy (in the measuring range) | ± (6 % MW + 0,6 % MEW); (conditions: installation to DIN ISO 2533; installation in pipes: DN15) |
Accuracy [K] | ± 2; (medium flow in the limit area of the flow measurement range) |
---|
Response time [s] | 0.1; (dAP = 0) |
---|---|
Damping process value dAP in steps [s] | 0 - 0,2 - 0,4 - 0,6 - 0,8 - 1 |
Parameter setting options | Flow monitoring; quantity meter; Preset counter; hysteresis / window; normally open / closed; current/pulse output; display can be rotated and switched off; Display unit; medium selection |
---|
Communication interface | IO-Link | ||||
---|---|---|---|---|---|
Transmission type | COM2 (38,4 kBaud) | ||||
IO-Link revision | 1.1 | ||||
SDCI standard | IEC 61131-9 | ||||
Profiles | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis | ||||
SIO mode | yes | ||||
Required master port class | A | ||||
Process data analog | 3 | ||||
Process data binary | 2 | ||||
Min. process cycle time [ms] | 4.1 | ||||
Supported DeviceIDs |
|
Ambient temperature [°F] | 32...140 |
---|---|
Storage temperature [°F] | -4...185 |
Max. relative air humidity [%] | 90 |
Protection | IP 65 |
EMC |
|
||||||||
---|---|---|---|---|---|---|---|---|---|
Vibration resistance |
|
||||||||
MTTF [years] | 227 | ||||||||
Pressure equipment directive | sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Weight [g] | 925.5 |
---|---|
Material | PBT-GF20; PC; PC; stainless steel (1.4301 / 304); FKM |
Materials (wetted parts) | stainless steel (1.4301 / 304); ceramics glass passivated; PEEK; polyester; FKM; aluminum anodized |
Process connection | threaded connection 1/2" NPT DN15 |
Display |
|
||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Display unit | scfm; scfh; scf; °F |
Remarks |
|
|||
---|---|---|---|---|
Pack quantity | 1 pcs. |
Connection | Connector: 1 x M12; coding: A |
---|